• 제목/요약/키워드: Radiation equipment

검색결과 599건 처리시간 0.023초

LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석 (Analysis of Local Exposure Levels of Radiation Emitted from Soft X-ray Ionizers in LCD Manufacturing Processes)

  • 김준범;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.342-352
    • /
    • 2021
  • Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics. Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement. Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.

무선기기 보호를 위한 ISM 기기의 방사 한계치에 관한 연구 (Study on Radiation Limit of ISM Equipment for Protecting Radio Device)

  • 심용섭;이일규;홍선의
    • 한국위성정보통신학회논문지
    • /
    • 제6권2호
    • /
    • pp.10-14
    • /
    • 2011
  • 본 논문은 최근 급증하는 ISM(Industrial Scientific Medical) 기기 및 무선기기의 사용 증가에 따라 ISM 기기와 무선기기가 인접한 공간에서 운용될 경우 상호간에 간섭이 예측되는 상황에서, ISM 기기와 무선기기 상호간에 간섭 없이 양립할 수 있도록 ISM 기기의 방사 한계치 산출 방법을 제시하였다. ISM 기기의 방사 한계치는 원하는 무선기기의 신호에 무선기기 보호를 위해 요구되는 보호비를 적용하고 이에 보정 요소를 고려하여 산출한다. 이어서 한계치 산출이 요구되는 시나리오를 제시함과 동시에 Matlab GUI(Graphical User Interface)를 이용한 방사 한계치 산출 S/W를 구현하였다. 본 논문에서 제시한 ISM 기기의 방사 한계치 산출 방법은 ISM 기기로부터 무선기기를 보호하기 위한 방안으로 활용될 것으로 기대된다.

항공보안장비 방사선 누출량 측정을 위한 평가 기준 및 절차에 관한 연구 (A Study on Evaluation Criteria and Procedures for Measuring Radiation Leakage of Aviation Security Equipment)

  • 김기현;정예은;김예준;김용수
    • 품질경영학회지
    • /
    • 제51권3호
    • /
    • pp.435-444
    • /
    • 2023
  • Purpose: To attain advanced performance certification, safety aspects along with functionality and performance are essential. Hence, this study suggests radiation leakage assessment methods for aviation security equipment during its performance certification. Methods: Detection technology guided the choice of radiation leakage assessment targets. We then detailed measurement and evaluation methods based on equipment type and operation mode. Equipment was categorized as container or box types for establishing measurement procedures. Results: We've developed specific radiation leakage assessment procedures for different types of aviation security equipment, crucial for ensuring airport safety. Using these procedures allows efficient evaluation of compliance with radiation leakage standards. Conclusion: The suggested radiation leakage assessment method aims to enhance aviation security and reliability. Future research will focus on identifying risks in novel aviation security equipment detection technologies and establishing safety standards.

펄스방사선에 대한 전자장비 방호용 모듈구현 및 기능시험 (Implementation of the Radiation Protection Module for Electronic Equipment from Pulsed Radiation and Its Function Tests)

  • 이남호
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1421-1424
    • /
    • 2013
  • The electronic equipment which is exposed to high level pulsed radiation is damaged by Upset, Latchup, and Burnout. Those damages come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appear as losses of a power in military weapon system or as a blackout in aerospace equipment and eventually caused in gross loss of national power. In this paper, we have implemented a RDC(Radiation detection and control module) as a part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC, which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator, is designed to protect the an important electronic circuits from the a pulse radiation. To verify the functionality of the RDC, LM118s, which had damaged by the pulse radiation, were tested. The test results showed that the test sample applied with the RDC was worked well in spite of the irradiation of a pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with the RDC had the functionality of radiation protection for the electronic devices.

진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008- (General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008-)

  • 강희두;동경래;권대철;최준구;정재호;정재은;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

안전조치 검증장비의 극한 온도환경 적용성 평가 (Evaluation of Usability in Extreme Temperature Environments of Safeguards Equipment)

  • 백희균;이진원;신중기
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.71-78
    • /
    • 2024
  • For most commercial radiation measurement equipment, manufacturers specify an operating temperature in the range of 0 to +40℃. However, in environments that exceed the quality assurance performance of the safeguards equipment, such as the winter environment in North Korea, the performance of the equipment deteriorates or normal use is impossible. In this study, safeguards equipment measurements were performed by creating an extreme temperature environment using a constant temperature and humidity test chamber. The safeguards equipment used in the evaluation was MIRION's Inspector-2000-based equipment, which evaluated the usability in extreme temperature environments using three types of detection units: NaI(Tl), CZT, and HPGe.

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • 제12권2호
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

디지털 유방촬영장비에 관한 공간선량율 평가 (The Evaluation of Space Dose Distribution for Digital Mammography Equipment)

  • 정홍문;정재은;현혜진;원도연
    • 한국방사선학회논문지
    • /
    • 제9권1호
    • /
    • pp.61-65
    • /
    • 2015
  • 유방촬영장비는 여성의 조기 유방의 병변을 진단하기 위하여 필수적으로 사용되는 장비이다. 계속적인 디지털 유방촬영장치가 보급되어짐에 따라 현재에는 대부분의 의료기관에서 디지털 유방촬영장치를 사용하고 있다. 하지만 이러한 디지털장비인 CR 또는 DR 유방촬영술의 무분별한 사용으로 여성 환자의 평균유효선량이 증가되고 있다. 이번 연구는 여성환자에게 사용되는 디지털 유방촬영장비의 공간선량율을 평가하여 방사선유효선량 과다 피폭으로 인하여 발생할 수 있는 방사선 2차 피해을 인식시키고자 하였으며, 더 나아가 디지털 유방촬영장치에서 발생되는 공간선량율 측정함으로써 환자에게 직접 촬영을 하는 방사선사 안전의식을 인식시키고자 한다. 결론적으로 디지털 유방촬영장비의 공간선량은 촬영장비를 기준으로 수평으로 높은 수치를 나타내었다. 이러한 결과를 고려한다면 디지털 유방촬영장비의 설치시에 수평 방향을 피하여 방사선사의 조작위치를 변경하거나 디지털 유방촬영 장비로부터 수평으로 되는 부위에 납유리차폐의 보완이 이루어져야 할 것이다.

Long-term Radiation Dose Reduction Plan of KHNP

  • Kim, Saeng-Ki;Shin, Sang-Woon;Lim, Byoung-Chan
    • Journal of Radiation Protection and Research
    • /
    • 제28권2호
    • /
    • pp.137-143
    • /
    • 2003
  • Annual radiation dose limit to radiation worker was substantially lowered in Korea by the adoption of 1990 recommendations of the International Commission on Radiation Protection (ICRP 60) in its legislation. On the other hand, radiation management environment in nuclear power plants is getting more worse because of the accumulation of radiation sources inside the system and the frequent need for maintenance according as the operation years of nuclear power plants increase. Therefore, Korea Hydro & Nuclear power Co., Ltd. (KHNP) has established a long-term 10 years plan from 2001 to 2010 for the reduction of radiation dose to workers. The plan is aimed for the reduction of annual dose per unit averaged over 5 years from 0.9 man-Sv in 2001 to 0.75 man-Sv in 2010 by radiation source reduction, equipment/tool improvement or new equipment development for easy maintenance, and the improvement of administration and system.