• Title/Summary/Keyword: Pumping power

Search Result 359, Processing Time 0.025 seconds

A Study on the Total Head Decision of Pump for Regional Water Supply Facilities (광역상수도용 펌프의 전양정 결정에 관한 연구)

  • Kim, Kyung-Yup;Suh, Sang-Ho;Lee, Jung-Woo;Roh, Hyung-Woon;Kim, Sang-Gyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.165-170
    • /
    • 2001
  • An extensive range of pumping facilities are employed in the regional water supply system in metropolitan areas, and optimization and the systematic combination of the Pump facilities have direct bearing on the stability and economy of the water supply system concerned. These systems must be able to guarantee stability, efficiency and offer high reliability. Preparation of metropolitan area regional water supply system construction project must include a basic plan which takes into account the suitability of pumping facilities to be used, the environment in which facilities will be installed, man-power requirements and basic operational and management policies. This paper contains over-all analysis of the management of metropolitan area regional water supply systems as like Jayang, Paldang 1st pump station. In the study, it aims to prepare counterplan which will be operated and managed the pump upon the operational conditions and to suggest the proposal for water facilities codes to decides total head of pump in Korea.

  • PDF

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

PV module manufacture for application of Building Integrated photovoltaic system (건물일체형 태양광발전시스템(BIPV) 적용을 위한 태양전지모듈 제조)

  • Kang Gi-Hwan;Yu Gwon-Jong;Han Deuk-Young;An Hyung-Geun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1465-1467
    • /
    • 2004
  • In this paper, deduced manufacturing condition of glass/glass curtain wall module and metal curtain wall module. From the results. lamination condition of glass/glass curtain wall module deduced optimum in pumping $time-120^{\circ}C$ 23min, slow $press-120^{\circ}C$. 300mmHg. 3min. standard $press-120^{\circ}C$. 200mmHg. 0.5min. fast $press-120^{\circ}C$. 100mmHg. 0.3min and $curing-140^{\circ}C$, 6min, and lamination condition of metal curtain wall module deduced optimum in pumping $time-120^{\circ}C$. 8min, slow $press-120^{\circ}C$, 700mmHg. 0.5min, standard $press-120^{\circ}C$, 600mmHg, 0.5min. fast $press-120^{\circ}C$, 100mmHg. 1.5min and $curing-140^{\circ}C$. 6min. This time. power uniformity of glass/glass curtain wall module and metal curtain wall module showed each ${\pm}2.7\%,\;{\pm}2.12\%$.

  • PDF

A Study on the Evaluation of the ESS Capacity of Considering for Charge-Discharge Characteristic and CO2 Emission in Jeju (배터리 충방전특성을 고려한 제주계통의 적정 ESS용량과 탄소배출량 산정에 관한 연구)

  • Ku, Bon-Hui;Cha, Jun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.455-460
    • /
    • 2014
  • South Korea's power consumption is increasing every year. For stable electric power supply, more generation facilities are needed. But it is not easy to build nuclear power generation facilities, so provision of renewable energy is thought of as the solution. For the system's stable management, practical use of energy storing system is needed. Currently, pumping up electric power station is considered most useful. In this study, we have calculated the least amount of energy storing device by considering the renewable energy, HVDC, and change in power for the appliance of ESS in Jeju system, according to The 6th Basic Plan for Long-term Electricity Supply and Demand. Also we have calculated the amount of the battery and about the load equalizing effect to use battery as power storing device. Finally, we have calculated the reduction of electricity generation and the reduction of $CO_2$ emission with this study.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

Passive Power Factor Correnction Circuits for Electronic Ballasts using Voltage-Fed and Current-Fed Reconant Inverters (전압원 및 전류원 구동 공진형 인버터로 구성된 형광등용 전자식 안정기의 역률개선에 적합한 수동 역률개선 회로에 관한 연구)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.515-522
    • /
    • 1999
  • Several power factor correction(PFC) circuits are presented to achieve high PF electronic ballast for both v voltage-fed and current-f,어 ek'Ctronic ballast. The proposed PFC circuits use valley-fil[(VF) type DClink s stages modified from the conventional VF circuit to adopt the charge pumping method for PFC operations d during the valley intervals. In voltage-fed ballast, charge pump capacitors are connected with the resonant c capaCltor In current-fed type, the charge pump capacitors are connc'Ctc'Cl with the additional second따y-side of t the power transformer. The measured PF is higher than 0.99 and THD is about 10% for all proposed PFC c circuits. The lamp current CF is also acceptable in the proposed circuits. The proposed circuit is suitable for i implementing cost longrightarroweffective electronic ballast.

  • PDF

A Experimental Study on the Effects of the Impingement-wall on the Spray and Combustion Characteristics of Direct-Injection LPG (충돌벽면이 직분식 LPG의 분무 및 연소 특성에 미치는 영향에 관한 실험 연구)

  • Hwang, Seong-Ill;Chung, Sung-Sik;Yeom, Jeong-Kuk
    • Journal of Power System Engineering
    • /
    • v.19 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • As an alternative fuel that can be used in SI engine, LPG is one of clean fuels with larger H/C ratio compared to gasoline, low $CO_2$ emission, and small amount of pollutants such as sulfur compounds. When LPG is used in spark ignition engine, volumetric efficiency of the engine can be improved and pumping loss can be reduced by performing direct injection into the combustion chamber instead of port fuel injection. LPG-DI engine allows for lean combustion and stratified combustion under low load. In case of stratified combustion, air fuel ratio can be greatly increased compared to theoretic mixture ratio combustion. Improved thermal efficiency of the engine and reduced pumping loss can be expected from stratified combustion. Accordingly in this study, an experimental apparatus for visualization was designed and manufactured to study the combustion process of LPG after injection and ignition, intended to examine ignition probability and combustion characteristics of spark ignition direct injection(SIDI) LPG fuel. Ambient pressure, ambient temperature and fuel injection pressure were found as important variables that affect ignition probability and flame propagation characteristics of LPG-air mixture. Also, it was verified that the injected LPG fuel can be directly ignited by spark plug under appropriate ambient conditions.

Numerical Study of Agitation Performance in a Drilling Mud Mixing Tank to Non-Newtonian Rheological Properties (시추용 머드혼합탱크의 비뉴턴 유체 모델에 대한 교반성능의 수치해석적 연구)

  • Im, Hyo-Nam;Lee, Hee-Woong;Lee, In-Su;Choi, Jae-Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.29-37
    • /
    • 2014
  • Non-Newtonian fluid mechanics takes charge of an important role in the oil industries. Especially in the oil well drilling process, the drilling fluid such as mud keeps the drill bit cool and clean during drilling, with suspending drill cuttings and lubricating a drill bit. The purpose of this study is to examine the effect of fluid mud rheological properties to predict different characteristics of non-Newtonian fluid in the mud mixing tank on offshore drilling platforms. In this paper, ANSYS fluent package was used for the simulation to solve the hydrodynamic force and to evaluate mud mixing time. Prediction of the power consumption and the pumping effectiveness has been presented with different operating fluid models as Newtonian and non-Newtonian fluid. The comparison between Newtonain mud model and non-Newtonian mud model is confirmed by the CFD simulation method of drilling mud mixing tank. The results present useful information for the design of the drilling mud mixing tanks and provide some guidance on the use of CFD tool for such non-Newtonian fluid flow.

A Study on Finned Tube Used in Turbo Refrigerator(III) -for Pressure Drop- (터보 냉동기용 핀 튜브에 관한 연구 (III) -압력 손실에 관하여-)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.6 no.1
    • /
    • pp.58-76
    • /
    • 1994
  • Heat transfer and pressure drop measurements are made on low integral-fin tubes in turbulent water flow condition. The integral-fin tubes investigated in this paper are nominally 19mm in diameter. Eight tubes have been used with trapezoidally shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. Plain tube having same diameter as finned tube is also tested for comparison. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken on steady state. The heat transfer loop is used for testing single long tubes and cooling water is pumped from a storage tank through filters and flowmeters to the horizontal test section where it is heated by steam condensing on the outside of the tube. The pressure drop across the test section is measured by means of pressure gauge and manometer. Each tube tested is cleaned with sodium dichromate pickling solution and well rinsed with water prior to installation in the test section. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, heat transfer of finned tube is enhanced up to 4 times as that of a plain tube at constant Reynolds number and up to 2 times at constant pumping power. 2. Friction factors are up to 1.6~2.1 times those of plain tube. 3. At a given Reynolds number, Nusselt number decrease with increasing pitch to diameter. 4. The constant pumping power ratio for low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio.

  • PDF

Analysis of the Magnetic Field Distribution and the Current Characteristics of Rotating Type Low Tc Superconducting Power Supply (회전자속형 초전도 전원장치의 박막상에서의 2차원 자장분포 및 전류 특성 해석)

  • Sim, Ki-Deok;Kim, Ho-Min;Yoon, Yong-Soo;Chu, Yong;Han, Tae-Su;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.343-345
    • /
    • 1998
  • By computer simulation, the pattern of magnetic field distribution on the Nb-foil of a rotating flux type superconducting power supply has been calculated. Using the results, the current pumping rate has been calculated and compared with the results obtained by the experiment. The experiment has been executed with small-size flux-rump in the environment of LN2 and LHe in order to compare the pattern of magnetic filed in the superconducting state and in the normal state. Five hall-sensor was located on the center, right side, left-side, upper side, lower side of the Nb-foil in order to obtain more accurate pattern of the magnetic field generated by rotating pole. In the simulation, the effects of the excitation-magnet and the iron core located at the inner-side and circumference of the magnet have been considered. By comparing the data from the experiment and the results from the simulation, the size of normal spot estimated. At the same time, by calculating the linkage flux, the current-pumping-rate has been obtained. Consequently, the results obtained from experiment and simulation coincided as expected.

  • PDF