A Study on the Total Head Decision of Pump for Regional Water Supply Facilities

광역상수도용 펌프의 전양정 결정에 관한 연구

  • 김경엽 (한국산업기술대학교 기계공학과) ;
  • 서상호 (숭실대학교 기계공학과) ;
  • 이정우 (휴먼아이티) ;
  • 노형운 (조선대학교 항공조선공학부) ;
  • 김상균 (한국수자원공사 수도설비처)
  • Published : 2001.11.01

Abstract

An extensive range of pumping facilities are employed in the regional water supply system in metropolitan areas, and optimization and the systematic combination of the Pump facilities have direct bearing on the stability and economy of the water supply system concerned. These systems must be able to guarantee stability, efficiency and offer high reliability. Preparation of metropolitan area regional water supply system construction project must include a basic plan which takes into account the suitability of pumping facilities to be used, the environment in which facilities will be installed, man-power requirements and basic operational and management policies. This paper contains over-all analysis of the management of metropolitan area regional water supply systems as like Jayang, Paldang 1st pump station. In the study, it aims to prepare counterplan which will be operated and managed the pump upon the operational conditions and to suggest the proposal for water facilities codes to decides total head of pump in Korea.

Keywords