• Title/Summary/Keyword: Protective device

Search Result 272, Processing Time 0.028 seconds

A Study of protective measures of the source program for the development of the Internet of Things (IoT): Protection of the program as well as plagiarism research (사물인터넷(IoT)발전을 위한 소스프로그램 보호방안 연구: 프로그램의 보호와 유사표절 연구)

  • Lee, Jong-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.31-45
    • /
    • 2018
  • Recent dramatical development of computer technology related to internet technology intensifies the dispute over software of computer or smart device. Research on software has been flourished with political issuing of fierce competition among nations for software development. Particularly industrial growth in ethernet based big data and IoT (Internet of Things) has promoted to build and develop open source programs based on java, xcode and C. On these circumstances, issue on software piracy has been confronted despite the basic security policy protecting intellectual property rights of software and thus it is of substantial importance to protect the rights of originality of source program license. However, the other issue on source technology protection of developer is the possibility of hindrance to advancement in industry and culture by developing programs. This study discuss the way of enhancing legal stability of IoT application program development and reinforcing precision in inspection of program plagiarism by analyzing the source programs with newly introducing text mining technique, thus suggests an alternative protective way of infringement of personal information due to duplicating program.

Protection Effects According to the Conditions of Installations of SPDs for Information-Oriented Equipments (정보화 기기용 SPD의 설치조건에 따른 보호효과)

  • Lee, Bok-Hee;Lee, Dong-Moon;Cheong, Dong-Chul;Lee, Su-Bong;Lee, Seung-Chil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Recently, there are increasing social needs for stable supply of electric power and securing high quality of information and communication services. In this work, to propose the effective protection countermeasures of information-oriented equipments against lightning surges, the protection effects of surge protective devices(SPDs) were experimentally investigated using actual-sized test circuits in various installation conditions. As a result, it was found that the protection effect of SPDs is quite different depending on the factors, such as the grounding system of power source, numbers of branch circuits, wiring method of grounding leads, and etc. In case of installing SPDs for information-oriented equipments, including all electric power lines and communication lines, the common grounding should be the most effective. Wiring method containing grounding leads with power lines in metal conduit is suitable to improve the surge cutoff performance of SPDs.

Effective Protection Methods of Household Electric Appliances. from Lightning Surges (가정용 전기기구의 효과적인 뇌서지 보호기법)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.

Investigation of Experimental Acute Ischemic Myocardium with a Microdialysis Appratus (미세 투석기를 이용한 실험적 급성 허혈 심근에 관한 영구)

  • Park, Seong-Dal;Kim, Song-Myeong
    • Journal of Chest Surgery
    • /
    • v.26 no.6
    • /
    • pp.441-451
    • /
    • 1993
  • Protective effect of superoxide dismutase[SOD] and substrates on acute ischemic and reperfused myocardium was assessed by cardiac microdialysis. 30 Rabbits were divided into 4 groups; normal control group [group I, n=5], ischemic group [group II, n=5], SOD treated group [group III, n=10], and substrates treated group [group IV, n=10]. After a microdialysis apparatus was implanted in rabbit myocardium, coronary artery was occuluded for 5 minutes and reperfusion was performed for 30 minutes. Hemodynamic changes, CK-MB isoenzyme level and adenine ring compound level in effluent dialysates [equilibrated with interstitial fluid], and ultrastructural changes of myocardial cell were analysed. Systolic blood pressure at 10 and 30 minutes after reperfusion was higher in group III and IV than in group II [p<.05]. Also percent recovery of systolic blood pressure in group III [p<.01] and IV [p<.02] was higher than in group II. CK-MB isoenzyme level in effluent dialysates was peaked at 10 minutes after reperfusion, thereafter decreased in group II, III and IV. At 30 minutes after reperfusion, its level was lower in group III and IV than in group II[p<.05]. Adenine ring compound level in effluent dialysates increased till 10 minutes after reperfusion and progressively decreased. At 10 and 30 minutes after reperfusion, its level was lower in group III and IV than in group II without significance. Degree of myocardial damage was estimated by scoring of mitochondrial injury. Group I was within normal range and most severe injury was seen in group II. And the score of mitochondrial injury in group III and IV was lower than in group II. In conclusion, SOD and substrates[KMP solution] had protective effect on stunned myocardium. The microdialysis appratus was a good device for studying stunned myocardium, and cardiac microdialysis might be a unique technique for analysis of regional intramyocardial interstitial fluid.

  • PDF

A Simulation Program for Protection Coordination in the Power Distribution System with Distributed Generators (분산전원 연계 배전계통의 보호협조 정정 프로그램 개발)

  • Kim, Sang-Ok;Seo, In-Yong;Lee, Heung-Ho;Rho, Dae-Seok
    • Journal of the Korea Society for Simulation
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A higher penetration of renewable energy sources and adoption of renewable portfolio standard(RPS), the penetration of distributed generators(DGs) into power distribution network is becoming a threat for the safe operation of distribution network. The ground fault current of DGs can cause parasitic trip and mal-trip of protective device in the power distribution network. KEPRI has developed a simulation program for current setting of protective devices in DGs connected distribution network. In this study, we analyzed fault currents of a sample network in two cases, i.e. case 1 is for no DG connection, case 2 for a DG connection. We performed protection coordination for relays installed in the network and analyzed the contribution of a DG.

A Study on ESD Protection Circuit with Bidirectional Structure with Latch-up Immunity due to High Holding Voltage (높은 홀딩 전압으로 인한 래치업 면역을 갖는 양방향 구조의 ESD 보호회로에 관한 연구)

  • Jung, Jang-Han;Do, Kyung-Il;Jin, Seung-Hoo;Go, Kyung-Jin;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.376-380
    • /
    • 2021
  • In this paper, we propose a novel ESD protection device with Latch-up immunity properties due to high holding voltages by improving the structure of a typical SCR. To verify the characteristics of the proposed ESD circuit, simulations were conducted using Synopsys TCAD and presented compared to existing ESD protection circuits. Furthermore, the variation of electrical properties was verified using the design variable D1. Simulation results confirm that the proposed ESD protective circuit has higher holding voltage properties and bidirectional discharge properties compared to conventional ESD protective circuits. We validate the electrical properties with post-design TLP measurements using Samsung's 0.13um BCD process. And we verify that the proposed ESD protection circuit in this paper is well suited for high voltage applications in that it has a latch-up immunity due to improved holding voltage through optimization of design variables.

Evaluation of dental status using a questionnaire before administration of general anesthesia for the prevention of dental injuries

  • Kyungjin Lee;Seo-Yul Kim;Kyeong-Mee Park;Sujin Yang;Kee-Deog Kim;Wonse Park
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 2023
  • Background: Dental evaluation and protection are important for preventing traumatic dental injuries when patients are under general anesthesia. The objective of the present study was to develop a questionnaire based on dentition-related risk factors that could serve as a valuable tool for dental evaluation and documentation. Methods: We developed a questionnaire for dental evaluation before administration of general anesthesia, investigated the association between patient-and-dentist responses and mouthguard fabrication, and assessed response agreement between 100 patients. Results: Protective mouthguards were fabricated for 27 patients who were identified as having a high risk of dental injury. There was a strong association between dentists' responses and mouthguard fabrication, depending on the general oral health status, use of ceramic prosthesis, presence of masticatory pain related to periodontal diseases, gingival edema, and implants (P < 0.05). Response agreement between patients and dentists for items related to dental pain, loss of dental pulp vitality, root canal therapy, dental trauma, aesthetic prosthesis, tooth mobility, and implant prosthesis was high (Cohen's kappa coefficient κ ≥ 0.6). Conclusions: A high agreement was observed between patient-dentist responses and a strong association with mouthguard fabrication for items pertaining to ceramic prosthesis, masticatory pain, and dental implants. Patients with a "yes" response to these items are recommended to undergo a dental evaluation and use a dental protective device while under general anesthesia.

Study on Research for Reducing Radiation Dose of Head and Neck for Cephalometric Radiography System (두부규격방사선촬영장치의 두경부 피폭 저감에 대한 연구)

  • OH, Yoonjin;Shin, Jae-won;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.291-298
    • /
    • 2016
  • Recently, the interest in the orthodontic treatment for children is increased by a rise in national income level. The number of cephalometric radiography that could diagnose a malocclusion and malposition between teeth and jawbone increased. It required attention to radiation exposure, because the subject of dental examination is children which are more sensitive to radiation and the head and neck, the object of that include radiation sensitive organ such as the thyroid, bone marrow, eyes, salivary gland, and so on. In this study, we measured two-dimensional dose distribution in cephalometric radiography system (VATEC Pax-400C) using Agfa CP-G Plus film and MagicMax Dosimeter, and calculated radiation organ dose of head and neck through MCNPX simulation. And then we designed a radiation protective device to decrease radiation dose. The dose distribution of the cephalometric radiography system irradiated the head and neck overall as well as the oral and maxillofacial parts. The radiation organ dose calculated that thyroid, oesophagus and eyes are irradiated high, and the radiation organ dose decreased about 70 ~ 80% by the application of the radiation protective device. The results of this study will be used construction of database for dental radiation exposure and research of reducing radiation dose.

The Protective Effects of Statins towards Vessel Wall Injury Caused by a Stent Retrieving Mechanical Thrombectomy Device : A Histological Analysis of the Rabbit Carotid Artery Model

  • Lee, Seung Hwan;Shin, Hee Sup;Oh, Inho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.693-704
    • /
    • 2021
  • Objective : Endovascular mechanical thrombectomy (MT) has been regarded as one of the standard treatments for acute ischemic stroke caused by large vessel occlusion. Despite the wide use of stent retrievers for MT, arterial intimal damage caused when deployed stent is pulled has been a certain disadvantage. We hypothesized that statin could protect and stabilize vessel damage after endovascular MT using a stent retriever. In this animal study, we observed the protective effects of the statins towards MT-induced vessel wall injury. Methods : Twenty-eight carotid arteries of fourteen rabbits were used in the experiments with MT using stent retriever. We divided the rabbits into four groups as follows : group 1, negative control; group 2, positive control; group 3, statin before MT; and group 4, statin after MT. After MT procedures, we harvested the carotid arteries and performed histomorphological and immunohistochemical analyses. Results : In histomorphological analysis with hematoxylin and eosin and Masson's trichrome stain, significant intimal thickening (p<0.05) was observed in the positive control (group 2), compared to in the negative control (group 1). Intimal thickening was improved in the statin-administered groups (groups 3 and 4 vs. group 2, p<0.05). We also observed that statin administration after MT (group 4) resulted in a more effective decrease in intimal thickness than statin administration before MT (group 3) (p<0.05). We performed immunohistochemical analysis with the antibodies for tumor necrosis factor-alpha (TNF-α), cluster of differentiation (CD)11b, and CD163. In contrast to the negative control (group 1), the stained percentage areas of all immunological markers were markedly increased in the positive control (group 2) (p<0.05). Based on statin administration, the percentage area of TNF-α staining was significantly reduced (p<0.05) in group 3, compared to the positive control group (group 2). However, significant differences were not observed for CD11b and CD163 staining. In group 4, no significant differences were observed for TNF-α, CD11b, and CD163 staining (p≥0.05). The differences in the percentage areas of the different markers between the statin-administered groups (groups 3 and 4) were also not revealed. Conclusion : We presented that statin administration before and after MT exerted protective effects towards vessel wall injury. The efficacy of statins was greater post-administration than pre-administration. Thus, statin administration in routine prescriptions in the peri-procedural period is strongly advised.