• Title/Summary/Keyword: Portable System

검색결과 1,354건 처리시간 0.028초

근적외선 분광기술을 이용한 휴대용 감귤 당도 선과기 성능특성에 관한 연구 (A Study on the Performance Characteristics of Portable Analyzer for Determination of Sugar Content in Citrus Unshiu using Near Infrared Spectroscopy)

  • 윤성운;마상동;김명윤;김재열
    • 한국공작기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1-6
    • /
    • 2006
  • The purpose of this study is to develop to portable near infrared analyzer measuring the sugar content of the fruits on a tree before harvesting ones. The portable near infrared system consists of a tungsten lamp, a coaxial optical fiber bundle and a multi-channel detector, which has 256 pixels and a concave transmission grating. Reflectance NIR spectra of orange were recorded by using a coaxial optical fiber bundle. The spectra were collected over the spectral range $400{\sim}1100nm$. Partial least squares regression(PLSR) was applied for a calibration and validation for determination of sugar contents. The multiple correlation coefficient was 0.99 and standard errors of calibration(SEC) was 0.069 brix. The calibration model predicted the sugar content for validation set with standard errors of prediction(SEP) of 0.092 brix. The sugar content in fruits was successfully quantified using the portable near infrared analyzer.

MP3-Player 고객 만족 및 충성에 미치는 요인에 관한 연구 (A Study of Factors Influencing Customer Satisfaction and Loyalty of MP3-Player)

  • 김상현;김태훈;김판수
    • 산업경영시스템학회지
    • /
    • 제30권2호
    • /
    • pp.15-22
    • /
    • 2007
  • By the early 20 century, "workman" introduced by SONY was the leading portable analog sounder. However, at the same century, workman was pushed out from the portable sounder by iRiver developed by MPMAN.COM. This portable digital sounder is called MP3-Player (MP3P), and has become the most popular portable digital sounder in the current market. This study combined two customer satisfaction models, mobile internet customer satisfaction model (Yu, 2002), and portable communication customer satisfaction model (Bae, 2003), in order to empirically test consumption of MP3P and its satisfaction. The proposed model tested four constructs, company's image, product price, product design and product function, influencing customer satisfaction, which leads to affect customer loyalty. 267 survey responses were analyzed by using structural equation modeling (SEM). The results show that all constructs had significant impact. This study suggests a good understanding of consumer satisfaction and loyalty of MP3P and the future direction of MP3P research regarding to consumer satisfaction.

개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발 (A portable electronic nose (E-Nose) system using PDA device)

  • 양윤석;김용신;하승철;김용준;조성목;표현봉;최창억
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

EPET-WL: Enhanced Prediction and Elapsed Time-based Wear Leveling Technique for NAND Flash Memory in Portable Devices

  • Kim, Sung Ho;Kwak, Jong Wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권5호
    • /
    • pp.1-10
    • /
    • 2016
  • Magnetic disks have been used for decades in auxiliary storage devices of computer systems. In recent years, the use of NAND flash memory, which is called SSD, is increased as auxiliary storage devices. However, NAND flash memory, unlike traditional magnetic disks, necessarily performs the erase operation before the write operation in order to overwrite data and this leads to degrade the system lifetime and performance of overall NAND flash memory system. Moreover, NAND flash memory has the lower endurance, compared to traditional magnetic disks. To overcome this problem, this paper proposes EPET (Enhanced Prediction and Elapsed Time) wear leveling technique, which is especially efficient to portable devices. EPET wear leveling uses the advantage of PET (Prediction of Elapsed Time) wear leveling and solves long-term system failure time problem. Moreover, EPET wear leveling further improves space efficiency. In our experiments, EPET wear leveling prolonged the first bad time up to 328.9% and prolonged the system lifetime up to 305.9%, compared to other techniques.

휴대형 모바일 와이맥스 기지국 신호분석 시스템 설계 (Design of Portable Signal Analysis System for Mobile WiMax Base Station)

  • 최종호
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권1호
    • /
    • pp.39-45
    • /
    • 2011
  • 본 논문에서는 공통의 플랫폼을 기반으로 하는 모바일 와이맥스 기지국 운용용 휴대형 신호분석 시스템의 설계방법을 제안하고, 이를 하드웨어 모듈로 구현하였다. 새롭게 제안한 신호분석 방법은 RF 신호의 IF 신호로의 하향 변환 및 이득제어를 수행하는 광대역 RF 모듈과 계측 기능을 수행하는 DSP 기반 디지털 신호분석 모듈로 구현하는 것이다. 타 고정 대형 시스템과의 비교를 통해 수행한 신호분석 알고리즘의 성능을 검증한 결과, 분해능의 차이는 없음을 확인하였다.

응급환자 병원내 이송중의 모니터링을 위한 저전력형 휴대용 무선 ECG 시스템 개발 (Development of a Low-power Portable Wireless ECG System for Monitoring the Emergency Patient during Transfer in Hospital)

  • 장기웅;김지원;공세진;김철승;엄광문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2163-2164
    • /
    • 2006
  • It is desirable to monitor the vital signals, such as ECG, of a emergency patient during transfer in the hospital as well as in the ambulance. The purpose of this study is to develop a system which provides a real-time and wireless ECG to the medical staff nearby patient during transfer in hospital. In this context, we developed a low-power, low-cost and portable ECG system consisting of 1) ECG measurement and RF transmission module and 2) RF receiving and LCD display module. The developed system is expected to be useful in monitoring ECG of a patient during transfer in the hospital.

  • PDF

휴대용 임베디드 기기를 활용한 멀티미디어 교육용 시스템의 설계 및 구현 (Development of Multimedia Educational System Using the Portable Embedded Machine)

  • 오세종;이상범;김태귀;박성진
    • 한국산학기술학회논문지
    • /
    • 제7권4호
    • /
    • pp.608-615
    • /
    • 2006
  • 임베디드 시스템은 유비쿼터스 컴퓨팅 환경의 핵심 요소 중의 하나로서 다양한 활용 분야를 가지고 있다. 본 논문에서는 휴대형 임베디드 기기 및 임베디드 기기상에서 활용이 가능한 아동 교육용 컨텐츠를 개발함으로서 임베디드 시스템이 산업 분야뿐만 아니라 교육 분야에도 활용될 수 있는 가능성을 제시하였다. 개발한 시스템은 휴대형 게임기의 형태로 개발하여 언제 어디서나 용이하게 사용할 수 있고, 호스트 시스템 또는 인터넷과의 접속을 통하여 새로운 컨텐츠의 다운로드가 가능하다. 컨텐츠는 게임 및 멀티미디어의 형태를 취하여 아동의 흥미를 유발하도록 하였다.

  • PDF

육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가 II - 돈육의 미생물 총균수 예측을 통한 전자코 시스템 성능 검증 (Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats II - Performance analysis of electronic nose systems by prediction of total bacteria count of pork meats)

  • 김재곤;조병관
    • 농업과학연구
    • /
    • 제38권4호
    • /
    • pp.761-767
    • /
    • 2011
  • The objective of this study was to predict total bacteria count of pork meats by using the portable electronic nose systems developed throughout two stages of the prototypes. Total bacteria counts were measured for pork meats stored at $4^{\circ}C$ for 21days and compared with the signals of the electronic nose systems. PLS(Partial least square), PCR (Principal component regression), MLR (Multiple linear regression) models were developed for the prediction of total bacteria count of pork meats. The coefficient of determination ($R_p{^2}$) and root mean square error of prediction (RMSEP) for the models were 0.789 and 0.784 log CFU/g with the 1st system for the pork loin, 0.796 and 0.597 log CFU/g with the 2nd system for the pork belly, and 0.661 and 0.576 log CFU/g with the 2nd system for the pork loin respectively. The results show that the developed electronic system has potential to predict total bacteria count of pork meats.

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

Portable Energy Storage System for DC House and Emergency Response in Indonesia

  • Hudaya, Chairul;Aryani, Dwi Riana;Heatubun, Yosca Rose Anggita;Taufiqurahman, Wahyu;Verdianto, Ariono;Garniwa, Iwa;Sung, Yung-Eun
    • 적정기술학회지
    • /
    • 제5권1호
    • /
    • pp.33-37
    • /
    • 2019
  • One of main problems in developing electricity grid for archipelago country like Indonesia is the geographical concerns as it consists of many islands. In some rural areas, electricity has not been available yet due to the limited infrastructure access, leading to high investment cost. In this study, a portable energy storage system based on the lithium-ion batteries called Tabung Listrik or TaLis (DC-based power bank) and DC house system were proposed as the solution for providing electricity for rural areas with relatively lower cost. TaLis is designed to be portable so it is easy to carry around as well as it can be used for many purposes. Since 2017, TaLis prototype has been used as the energy storage in a DC house system at Sekolah Master Indonesia, where an array of PV rooftop is functioned as the main DC power supply. Besides, some TaLis were also dispatched for emergency response during the disaster situations in Indonesia, such as during the measles outbreak in Asmat-Papua, the earthquake disaster in Lombok and tsunami in Palu.