• Title/Summary/Keyword: Pole Location

Search Result 71, Processing Time 0.022 seconds

Design of Microstrip Duplexer with Attenuation Poles (감쇠극을 갖는 마이크로스트립 듀플렉서 설계)

  • Choi, Oh-Seog;Nam, Hun;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.924-930
    • /
    • 2003
  • In this paper, a novel miniaturized microstrip duplexer with attenuation pole is proposed. A three-pole microstrip CT(Cascade Trisection) two bandpass filters have each asymmetrically prescribed transmission zero are design and fabrication. This CT bandpass filter changes coupling structure, which not only shifts the location of attenuation poles but also improves skirt characteristics. The duplexer results of measurement with the cross coupling CT bandpass filters has been yielded better isolation and sharper skirt behavior than that with a conventional bandpass filter. The results of measurement are almost similar to those of simulation results.

A Study on the Vary Small K-band Triple-mode Cavity Resonator Bandpass Filter for Digital Microwave Communication (Digital Microwave 통신을 위한 K-band 초소형 Triple-mode 공동 공진기 대역통과 필터에 관한 연구)

  • 곽민우;안기범;민혁기;이주현;류근관;홍의석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.267-276
    • /
    • 1999
  • A 2 stage 6-pole bandpass filter (BPF) is designed and implemented by using K-band triple-mode cavity. The BPF has an 100MHz bandwidth at the center frequency of 18.5GHz and the response of the filter is Chebyshev function. The cavity filter uses two orthogonal $TE_{113}$ modes and one $TM_{012}$ mode. To obtain a Chebyshev response, the intercavity coupling between the adjacent cavities is accomplished by H-field component of TE modes parallel to slot plate. In this paper, the size and location of intercavity slot are determined by the detailed coupling equation from H-field of TE resonant modes in circular cavity. The measured results agree well with the theoretical one.

  • PDF

Sliding mode control for structures based on the frequency content of the earthquake loading

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • v.5 no.3
    • /
    • pp.209-221
    • /
    • 2009
  • A control algorithm for seismic protection of building structures based on the theory of variable structural control or sliding mode control is presented. The paper focus in the design of sliding surface. A method for determining the sliding surface by pole assignment algorithm where the poles of the system in the sliding surface are obtained on-line, based on the frequency content of the incoming earthquake signal applied to the structure, is proposed. The proposed algorithm consists of the following steps: (i) On-line FFT process is applied to the incoming part of the signal and its frequency content is recognized. (ii) A transformation of the frequency content to the complex plane is performed and the desired location of poles of the controlled structure on the sliding surface is estimated. (iii) Based on the estimated poles the sliding surface is obtained. (iv) Then, the control force which will drive the response trajectory into the estimated sliding surface and force it to stay there all the subsequent time is obtained using Lyapunov stability theory. The above steps are repeated continuously for the entire duration of the incoming earthquake. The potential applications and the effectiveness of the improved control algorithm are demonstrated by numerical examples. The simulation results indicate that the response of a structure is reduced significantly compared to the response of the uncontrolled structure, while the required control demand is achievable.

A Small Cavity Bandpass Filter using Triple-Mode Technique (삼중모드 기법을 이용한 소형 공동 공진기 대역통과 필터)

  • 홍의석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.535-541
    • /
    • 1998
  • A 2 stage 6-pole bandpass filter(BPF) is designed and implemented by using triple-mode cavity for satellite payload system. The BPF has an 100 MHz bandwidth at the center frequency of 14.5 GHz, Ku-band. The cavity filter uses two orthogonal $TE_{113}$ modes and one $TM_{012}$ mode. The intercavity coupling between the adjacent cavities results in a Chebyshev response and is accomplished by H-field component of TE modes. The size and location of intercavity slot are determined by the coupling equation from H-field of TE resonant modes in circular cavity. The measured filter response agrees well with the theoretical data.

  • PDF

A Study on Novel Hybrid Type Encoder Design for the Position Control with the High-resolution (고정도 위치제어용 Hybrid Type Encoder에 관한 연구)

  • Cho S. E.;Lee S. H.;Song S. G.;Park S. J.;Kwon S. J.;Kim C. U.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.87-94
    • /
    • 2005
  • This paper is about the compensation of phase angle error and amplitude difference in stationary 2 pole coordinates by the installation variation of sensor at low cost high resolution digital hybrid encoder. To solve the problem of amplitude difference at the existing hybrid encoder, we normalized the relative magnitude of the two analog signals. and also to solve the problem of installation variation when installed the sensor, we rotate the stationary 2 pole coordinates to compensate the location error of sensor. and we used and tested the QEP function and A/D port in DSP(TMS320F2812) to verify the mentioned proposed method.

Horizontal Stress Analysis of Electric Pole using Earth Pressure Cell from Mock-Up Tension Test (전주의 실물인장실험시 토압계를 이용한 수평토압분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.62-69
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. 4 anchor blocks decreased earth pressure at G.L.-0.9[m]. It is considered that 4 anchor blocks installed along 80[cm] vertically are main reason. Overall, when more anchor blocks are constructed, excavation area is large, and constructivity such as backfill is bad, therefore one anchor block would be preferred.

Methods of Weighting Matrices Determination of Moving Double Poles with Jordan Block to Real Poles By LQ Control (LQ 제어로 조단블록이 있는 중근을 실근으로 이동시키는 가중행렬 결정 방법)

  • Park, Minho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.634-639
    • /
    • 2020
  • In general, the stability and response characteristics of the system can be improved by changing the pole position because a nonlinear system can be linearized by the product of a 1st and 2nd order system. Therefore, a controller that moves the pole can be designed in various ways. Among the other methods, LQ control ensures the stability of the system. On the other hand, it is difficult to specify the location of the pole arbitrarily because the desired response characteristic is obtained by selecting the weighting matrix by trial and error. This paper evaluated a method of selecting a weighting matrix of LQ control that moves multiple double poles with Jordan blocks to real poles. The relational equation between the double poles and weighting matrices were derived from the characteristic equation of the Hamiltonian system with a diagonal control weighting matrix and a state weighting matrix represented by two variables (ρd, ϕd). The Moving-Range was obtained under the condition that the state-weighting matrix becomes a positive semi-definite matrix. This paper proposes a method of selecting poles in this range and calculating the weighting matrices by the relational equation. Numerical examples are presented to show the usefulness of the proposed method.

A Study on Type Classification and Recognition Using Structural Information in Character Pattern of HANGEUL Shape (한글 Shape 문자 Pattern에서의 구조적 정보를 이용한 형식분류와 인식 관한 연구)

  • 전종익;조용주;남궁재찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.2
    • /
    • pp.180-195
    • /
    • 1991
  • In this paper, we studied on new method of recognition using structural information to recognize character pattern in orginal shape of Hangeul. First, for the purpose of knowing location of character in input image. it processed Making block. Second, after we investigated. whether vertical vowel exited or not in character image accordingly the center of gravity of Hangeul. each character was classified into Type of Hangeul by searching location and length for horizontal vowel and short pole. Last, we processed it by means of template matching which calculate Uclid's distance on each Jaso in accordance to type classified. This paper made an experiment on 2350 characters and obtained 98.3% classifing rate and 95.2% recognizing rate.

  • PDF

Modified Mode Matching Technique for Analyzing Simple Expansion Chamber with Arbitrary Inlet/Outlet Location (임의의 입ㆍ출구 위치를 가지는 소음기 해석을 위한 개선된 모드일치법)

  • Kim, Bong-Jun;Jeong, Ui-Bong;Lee, Jeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1314-1322
    • /
    • 2000
  • The acoustic property of reactive type single expansion chamber can be analyzed by traditional plane wave theory. This theory can be applied in low frequency range and has good performance. But this theory can't include higher order modes, therefore another method is essential to analyze acoustic filter in high frequency range. Many researcher suggested the method that can concern higher order modes, and their methods are using mode matching technique. But there is no method that can be applied to the analysis of single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber. In this paper, the method which can analyze single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber using fundamental mode matching technique, was suggested and the predictions by this method was compared with those by the finite element method, and the influence of inlet/outlet location to acoustic performance of single expansion chamber is investigated and explained by higher order mode effects.

A robust control system design by a parameter space approach based on sign difinite condition

  • Kimura, Tetsuya;Hara, Shinji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1533-1538
    • /
    • 1991
  • A parameter space approach for robust control system design is developed by reducing several design specifications to sign definite conditions. It is shown that the gain and phase margin constraints for the parametric perturbed plant hold if and only if the four Kharitonov systems satisfy the margins. On pole location, it is shown that D-stability of convex combinations (1-t)p(s)+tq(s) can be determined by the coefficients corresponding to p(s) and q(s) based on the sign definite condition. We show a method of PI-type robust control system design as a useful example.

  • PDF