• 제목/요약/키워드: Plant Operations

검색결과 367건 처리시간 0.026초

Evaluation of Thermal Hazard in Neutralization Process of Pigment Plant by Multimax Reactor System (Multimax Reactor System을 이용한 안료제조시 중화공정의 열적위험성 평가)

  • Lee, Keun-Won;Han, In-Soo
    • Journal of the Korean Society of Safety
    • /
    • 제23권6호
    • /
    • pp.91-99
    • /
    • 2008
  • The identification of thermal hazards associated with a process such as heats of reaction and understanding of thermodynamics before any large scale operations are undertaken. The evaluation of thermal behavior with operating conditions such as a reaction temperature, stirrer speed and reactants concentration in neutralization process of pigment plant are described. The experiments were performed by a sort of calorimetry with multimax reactor system The aim of the study was to evaluate the results of heat of reaction in terms of safety reliability to be practical applications. It suggested that we be proposed safe operating conditions and securities for accident prevention on reactor explosion through this study.

Development of an Intellectual Property Core for Floating Point Calculation for Safety Critical MMIS

  • Mwilongo, Nelson Josephat;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • 제17권2호
    • /
    • pp.37-48
    • /
    • 2021
  • Improving the plant protection system against unforeseen changes/transients during operation is essential to maintain plant safety. Under this condition, it requires rapid and accurate signal processing. The use of an Intellectual Property (IP) core for floating point calculations for Safety Critical MMIS can make numerical computations easier and more precise, improving system accuracy. It can represent and manipulate rational numbers as well as a much broader range of values with dynamic range in nuclear power plant. Systems engineering approach (SE) is used through the development process, it helps to reduce complexity and avoid omissions and invalid assumptions as delivers a better understanding of the stakeholders needs. For the implementation on the FPGA target board, the 32-bit floating-point arithmetic with IEEE-754 standards has designed using Simulink model in Matlab for all operations of addition, subtraction, multiplication and division and VHDL code generated.

Configuration Management and Domestic and International nuclear power plant trends (형상관리와 국내외 원전 동향)

  • Ko, Min-Hyuck;Lee, Daesung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.351-353
    • /
    • 2022
  • There have been several nuclear accidents at home and abroad so far, and there have been major and small damages. Overseas, in order to reduce such accidents, the safety and reliability of nuclear power plant operations have been improved by introducing a technology called Configuration Management. Through basic information on Configuration Management and successful cases of introducing Configuration Management from overseas nuclear power plants, this paper checks the technical parts applicable to Korea and examines whether they can be newly applied by supplementing them for domestic nuclear power plants.

  • PDF

The study of plant application at flame management system with flame monitoring for pulverized coal firing boiler of thermal power plant (발전용 미분탄 연소 보일러 화염감시장치의 현장적용에 관한 연구)

  • Baeg, Seung-Yeob;Kim, Seung-Min
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.535-537
    • /
    • 2004
  • The flame image processing and it's analysis system has been developed for optimal coal firing of thermal power plant, especially for reducing NOx and safe operations. We aimed at gaining the relationship between burner flame image, emissions of NOx and LOI(Loss on ignition) in furnace by utilizing the flame image processing methods. And the relationship determines quantitatively the conditions of combustion on the individual burners. The test was conducted on Samchonpo thermal power plant #4 unit(560MW) of KOSEP which has 24 burners. The system simplified the burner adjustment works in accordance with the real time trending of flame behavior like NOx profiles and unburned carbon profiles for individual burners. But, This kind of conventional method increases the cost as the number of burner are increased. Also there is a difficulty to measure exhausted gas of each burner because of measurement errors. This paper intends to propose the useful "Flame Monitoring System" that can find Low NOX and LOI at the upper furnace and to compare with the conventional System.

  • PDF

Bioreactor Operating Strategy in Scultellaria baicalensis G. Plant Cell Culture for the Production of Flavone Glycosides (Flavonoid 배당체 생산을 위한 Scutellaria baicalensis G. 식물 세포 배양에서 생물반응기 운전전략)

  • 최정우;조진만;이정건;이원홍;김익환;박영훈
    • KSBB Journal
    • /
    • 제13권3호
    • /
    • pp.259-267
    • /
    • 1998
  • Optimal feeding strategies in bioreactor operation of Scutellaria baicalensis G. plant cell culture were investigated to maximize the production of flavone glycosides by using a structured kinetic model which can predict culture growth and flavone glycosides synthesis in a rigorous, quantitative manner. For the production of baicalin and wogonin-7-0-GA, the strategies for glucose feeding into Scutellaria baicalensis G. plant cell culture were proposed based on the model, which are a periodic fed-batch operation with maintenance of cell viability and of specific production rate respectively, and a perfusion operation with maintenance of specific production rate for baicalin and wogonin-7-0-GA. Simulation results showed that the highest volumetric concentration of flavone glycosides was obtained in a periodic fed-batch operation with maintenance of cell viability among all the suggested strategies. In the periodic fed-batch operations, the higher volumetric production of flavone glycosides was achieved compared with that in the perfusion operation. It can be concluded that a periodic fed-batch operation with maintenance of cell viability would be the optimal and practical operating strategy of Scutellaris baicalensis G. plant cell culture for the production of flavone glycosides.

  • PDF

A Study on Efficiency Improvement by Fine Tuning of Power Plant Control (제어시스템 튜닝에 의한 발전소 효율향상에 관한 연구)

  • Kim, Ho-Yol;Kim, Byoung-Chul;Byun, Seung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제61권10호
    • /
    • pp.1496-1501
    • /
    • 2012
  • A fine tuning on a control system is essential not only for stable operation but also for efficient operation of the power plant. There has been a very few studies on efficiency change by control system tuning. So, it was not clear that if it could be improved or not when the control is stable by fine tuning and how much it could be improved if it works. An accurate algorithm for measurement of the plant efficiency was newly introduced and implemented to measure integrated fuel flow and electricity MW output and to calculate the mean efficiency for given time. As a result, stable operation after fine tuning of control parameters for major controlled variables brought higher efficiency than un-stable operations like a cycling or an oscillation. The plant efficiency has been monitored during various tests and tunings to confirm how much it changes by tuning of the control system on power plant. Now, we can say that the efficiency can be improved in stable operation by fine tuning of the control system.

Heliostat Control System (Heliostat 제어시스템)

  • Park, Young-Chil
    • Journal of the Korean Solar Energy Society
    • /
    • 제29권1호
    • /
    • pp.50-57
    • /
    • 2009
  • Heliostat in the tower type solar thermal power plant is a mirror system tracking the sun's movement to collect the solar energy and it is the most important subsystem determining the efficiency of solar thermal power plant. Thus a good performance of it, which is mostly the accurate sun tracking performance under the various hazardous operating condition, is required. Heliostat control system is a system to manage the heliostat sun tracking movement and other operations. It also communicates with the master controller through the heliostat filed control system to receive and send the informations required to operate the heliostat as a part of the solar thermal power plant. This study presents a heliostat control system designed and developed for the 1MW solar thermal power plant. We first define the functionality of heliostat control system. Then sun tracking controller as well as the sun tracking algorithm satisfying the required functionality have been developed. We tested the developed heliostat control system and it showed a good performance in regulation of heliostat motion and communication.

Development of Start·Stop Control System at Water Turbine Generator for Tidal Power Plant (조력발전소를 위한 수차발전기의 기동·정지 제어시스템 개발)

  • Cho, Byong-Og;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제28권6호
    • /
    • pp.106-112
    • /
    • 2014
  • Recently, tidal power generation has gained much attention. South Korea's tidal power generation systems were imported from abroad by turnkey type and have being operated. Therefore, for efficient operation and technological independence of a tidal power system, development of core technology is required. This paper deals with the start stop control system of water turbine generator in the tidal power plant, as one of our development project results. Using the SCADA system, the status and operations of water turbine generator in the tidal power plant, as well as simulation for calculation of maximum power were carried out. A small model type of start stop control device was also developed. In addition, the control system in Sihwa tidal power plant was modeled, and the results obtained by the dynamic simulation were given in graphics by 2D simulator.

Concept of an intelligent operator support system for initial emergency responses in nuclear power plants

  • Kang, Jung Sung;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2453-2466
    • /
    • 2022
  • Nuclear power plant operators in the main control room are exposed to stressful conditions in emergency situations as immediate and appropriate mitigations are required. While emergency operating procedures (EOPs) provide operators with the appropriate tasks and diagnostic guidelines, EOPs have static properties that make it difficult to reflect the dynamic changes of the plant. Due to this static nature, operator workloads increase because unrelated information must be screened out and numerous displays must be checked to obtain the plant status. Generally, excessive workloads should be reduced because they can lead to human errors that may adversely affect nuclear power plant safety. This paper presents a framework for an operator support system that can substitute the initial responses of the EOPs, or in other words the immediate actions and diagnostic procedures, in the early stages of an emergency. The system assists operators in emergency operations as follows: performing the monitoring tasks in parallel, identifying current risk and latent risk causality, diagnosing the accident, and displaying all information intuitively with a master logic diagram. The risk causalities are analyzed with a functional modeling methodology called multilevel flow modeling. This system is expected to reduce workloads and the time for performing initial emergency response procedures.

A study of SDN/SON-based emergency communications systemprovisioning for nuclear power plant under extreme natural disaster (극한 자연재해 상황 하의 SDN/SON 기반 원자력발전소 비상통신망 구축방안 연구)

  • Choi, Taesang;Yoon, Sangsik;Lee, Junkyung;Cho, Yongsu;Lee, Sangjin
    • KNOM Review
    • /
    • 제22권3호
    • /
    • pp.31-39
    • /
    • 2019
  • This paper introduces our research results of SDN/SON-based emergeny communications system for nuclear power plant under extreme natural diaster like Fukusima nuclear power plant incident. In such a extreme situation, nuclear power plant operational staffs which do not have technical knowledge of network provisioning and operations have to deploy the emergency network. Thus our proposed system provides capabilities to provision an emergency network autonomically and enable voice and data services. It also describes our PoC system developed based on the proposed core technology and architecture with the results of system verification testing.