• Title/Summary/Keyword: Peak noise level

Search Result 158, Processing Time 0.029 seconds

Reduction of Radiated Noise in a Reciprocating Compressor (왕복동식 압축기의 방사소음 저감)

  • Kim, Yong-Tae;Lee, Jin-Woo;Joo, Jae-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.431-434
    • /
    • 2005
  • Generally, noise in a reciprocating compressor is attributed to the driving force of a pump. However, close examination shows that the noise heard by customers finally results from radiation of a shell in a compressor, the noise caused by both transmission through a shell and resonance with the natural frequency of a shell. Therefore, the peak frequencies contributing to the overall level of a compressor' noise are closely concerned with vibration of a shell. That's why radiated noise by vibration can be reduced by changing the mode of a shell and by shifting the peak frequencies to other ranges, which are not globally related with the overall noise level. In this paper, the main peak frequencies are analyzed to reduce the radiated noise of a shell, and the vibration characteristics of a shell are examined through Frequency Response Function and Finite Element Analysis. Moreover, the Operational Deflection Shape for a shell is measured with consideration of real driving force of a pump. Finally, the optimum position on a shell, closely related to the main peak frequencies, is found, and the overall noise level caused by radiated noise of a shell is noticeably reduced by mass or stiffness modification of the position.

  • PDF

Optimized Automatic Noise Level Calculations for Broadband FT-ICR Mass Spectra of Petroleum Give More Reliable and Faster Peak Picking Results

  • Hur, Manhoi;Oh, Han-Bin;Kim, Sung-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2665-2668
    • /
    • 2009
  • A new algorithm for determining noise level is proposed for more reliability in interpreting spectral data for complex Fourier transform ion cyclotron resonance (FTICR) mass spectra of petroleum. In the new algorithm, a moving window with a fixed number of data points was adopted, instead of a fixed m/z width. In the analysis of petroleum, it was found that a moving window of 50,000 or more data points was optimal. This optimized automated peak picking performed well even with frequency-dependant noise in the mass spectrum. Additionally, this fast, automated peak picking algorithm was suitable for the analysis of a large set of samples.

Low Frequency Pass-by Noise for Road Vehicle (도로교통 소음원에 의한 저주파 소음실태)

  • 정성수;서상준;조문재;김용태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.533-536
    • /
    • 2003
  • The Low frequency(1-200 Hz) noise levels radiated by road traffic were investigated. The results showed that the peak pass-by noise of truck with speed of 60km/h was about 75㏈. For the infra-sound frequency range, the noise was about 65㏈ and it was less value than expected. But the noise level will be increase as increasing the speed. The pass-by noise for train was also measured for comparison. The peak train noise was about 95㏈ and it will be enough noise level for a human body to give nuisance.

  • PDF

Characterization of Noise Exposure in the Tank Gun Drill Ranges (군대 전차포 훈련장에서의 소음노출 특성)

  • Hwang, Sung Ho;Park, Jae Bum
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.74-78
    • /
    • 2014
  • Objectives: Purpose of this study was to evaluate the noise level exposures at the different cannonball type and locations in the tank gun drill ranges. Methods: We visited the tank gun drill ranges and measured with a sound level meter(3M Quest SoundPro$^{TM}$) with the value of Peak(dB(A)). Results: The highest peak value of impulse noise level averaged 166.3 dB(A) at the site of loading solider. The highest peak value of impulse noise level by size of cannonball averaged 165.9 dB(A) at the 120 mm size cannonball of the tank. This result was significantly different from the other size of cannonballs such as 7.62 mm, 90 mm, and 105 mm(p < 0.001). Among the four types of soldier site on the tank, average noise levels of loading soldier, 156.6 dB(A), were higher than the other three types of soldier site (p > 0.05). Conclusions: This study confirmed that there were needed for a proper control to reduce the amount of impulse noise exposure at the tank gun drill ranges.

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF

An Effect of Revolutions Per Minute (r.p.m) in the Noise Characteristics (기계소(機械騷) 음(音)과 회전(回轉) 속도(速度))

  • Cha, Bong-Suk
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.94-101
    • /
    • 1977
  • Noise pollution, both in the environment and in the workplace, has been recognized as a major health hazard -one that can impair not only a person's hearing but also his physical and mental well-being. As industrialization progresses, the prevalence rate of occupational diseases is increasing, especially hearing loss, which has the highest prevalence rate among the occupational diseases. The major cause of noise is the construction of various large industries without any regulation of noise sources. Therefor, we must establish an enactment to control mechanical noise sources. as soon as possible. For the purpose of controlling the noise source, we must have exact data about such things as the sound level, the frequency of the peak sound and the revolutions per minute (r.p.m.) of the machine (a measure of the power of its motor). This study was undertaken in order to define the noise characteristics, the power of the machine's motor, the change of the sound level and the peak sound as the r.p.m. increases, and the permissible exposure time. The sample size of this study was 74 machines at 11 plants in 6 industries. The results are as follows; 1. The breakdown of the types of mechanical noise noted was : 63.6% continuous normal sound, 26.9% intermittent sound, 4.7% continuous repeating sound and 4.6% impulsive sound. 2. With respect to the type of industry, the overall sound level was the highest in the mechanical industry, with $103.8{\pm}2.8dB(A)$, and lowest in the textile industry, with $89.2{\pm}1.43dB(A)$. 3. With respect to the type of machine, the highest sound level was 124 dB(A) caused by Gauzing(II), in the mechanical industry, and the lowest was 76 dB(A) caused by Attachment (Jup Chack) (I) in the timber industry. 4. The shortest permissible exposure time to Gauzing(II) in the mechanical industry was less than 15 minutes. 5. Among 74 machines, 68.2% of the peak sound was situated in the high frequency range (52.7% at 2 KHz, 4.1% at 4 KHz and 1.4% at 8 KHz). 41.8% of the peak sound was in the middle frequency range (4.1% at 250Hz, 14.8% at 500Hz and 22.9% at 1KHz). 6. If one machine had two motors or more, the peak sound was shifted to the low frequency range. 7. As the r.p.m. increased, the overall and peak sound levels were increased without any change of the frequency of the peak sound. 8. Whenever the machines had the same kind and the same r.p.m., the overall and peak sounds were changed by the physicochemical characteristics of the raw materials and the management.

  • PDF

Noise Characteristics of Plumbing System with Wall Hanging Unit (층상배관 배수시스템의 소음 특성 평가)

  • Park, Cheol-Yong;Kim, Sang-Hoon;Jang, Dong-Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1421-1424
    • /
    • 2006
  • Recently Requirement of indoor environment is increased in APT. Among indoor noises of APT, noise of plumbing system in bathroom is very serious problem except of floor impact noise. Plumbing system with wan hanging unit make a good grade and recognition in rating noise of bathroom in grade of house rating. But it is hard to find a data which are measured in APT built. In this study, the effect of noise reduction is checked by measuring the noise of plumbing system with wall hanging unit that is built. As result the upper household's Peak sound level is measured 80dB(A), the under household's peak sound level is measured 40dB(A).

  • PDF

Noise Exposure Assessment at Military Rifle Ranges in South Korea (우리나라 군대 소총사격 훈련장에서의 소음노출평가)

  • Hwang, Sung Ho;Park, Jae Bum
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.261-265
    • /
    • 2013
  • The purpose of this study was to evaluate noise level exposures at different locations such as the left and right ears of the shooter, control room, waiting soldier location and drill ground. For this study, we visited two military rifle ranges and took measurements with a sound level meter (3M Quest SoundPro TM) at five different locations with values of Peak (dB(A)) and Max (dB(A)). The highest peak value of impulse noise level averaged 150.4 dB(A), ranging from 149.6 to 150.5 dB(A) at both the left and right ear sides. This result was significantly different between both left and right ear side locations and at other locations such as the control room, waiting soldier location, and drill ground (P < 0.001). Frequency of impulse noise exposure level showed that the left ear of shooter had the highest frequency (20 times) at over 150 dB(A). This study confirmed that there is a need for proper controls to reduce the amount of impulse noise exposure at military rifle ranges.

A Study on the Establishment of Management Criteria for Underwater Noise (수중소음 관리 기준 설정을 위한 소고)

  • Lim, Dae-Kyu;Shin, Young-Cheol;Jun, Yang-Bae
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.119-132
    • /
    • 2010
  • There are many dispute with a construction due to such environment problem as vibration and noise. Generally, we have a standard for acceptance level in land. But we have not a sufficient standard for acceptance level or guide line in underwater sound. In other countries, a acceptance level or guide line in underwater sound has been suggested. Especially the management criterion of underwater noise for fish has bee suggested using the measurement data (peak pressure, rms, energy and SEL) by a hydrophone. In Korea, there is no management criterion of underwater noise for fish. This study suggested the management criteria of underwater noise for fish based on the measured data by a hydrophone.

Daytime and Night-time Noise Exposure Assessment for Soldiers at a Military Rifle Range (군대 소총사격장에서 군인들의 주야간 소음노출평가)

  • Hwang, Sung Ho;Park, Jae Bum
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.4
    • /
    • pp.354-359
    • /
    • 2013
  • Objectives: The purpose of this study was to investigate exposure levels to K2 rifle noise at a military rifle range among soldiers in training, the left and right ears of shooters, and control managers in the day and night times. Methods: For this study, we visited military rifle ranges and measured the noise of a K2 rifle with a sound level meter (3M Quest SoundPro$^{TM}$) at four different locations with values of Peak (dB(A)) and Max (dB(A)). Results: The highest peak value of impulse noise level averaged 150.4 dB(A), ranging from 149.7 to 150.5 dB(A) at the left-ear side. Impulse noise levels in the daytime were also recorded as higher than during the night. This result was significantly different between daytime and nighttime locations, such as soldier training, right ear of shooter, and control manager (P < 0.001). Conclusion: This study confirmed that there is a need for proper management of impulse noise at military rifle ranges.