• Title/Summary/Keyword: Partial insulation

Search Result 462, Processing Time 0.03 seconds

Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface (XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형)

  • Cho, Kyung-Soon
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.2
    • /
    • pp.357-364
    • /
    • 2005
  • The prefabricated type used generally in Korea to join cable runs on new installations or to repair broken Cable runs on existing installations, because installation is very simple and save time. This type is a permanent, shielded and submersible cable joint for direct burial or vault application. It confirms to the requirements of IEEE std. 404-1993 by factory testing, but many problems of insulated cable systems are caused by internal defects of the joint part which have to be mounted ensile. Faults arise from impurities or voids. A suitable solution for a monitoring of cable joints during the after-laying test and service is partial discharge detection. Specimen obtained 1mm thickness from the insulation of real power cable and cable joint. <중략>The partial discharges are measured to determine their time dependence for 60 minutes and the influence of applied electrical stress under 30kV. $\Phi-q-n$ properties were measured using detection impedance, high pass filter and computerized data acquisition system. Statistic Value like maximum charge, repetition rate, average charge, etc. are calculated. It is possible to quantitative analysis of $\Phi-q-n$ properties from this statistic value and pattern analysis.

  • PDF

Noise Elimination Algorithm for Detecting Partial Discharge of Generator Stator Winding Considering Relation of Periphery Signals (고압 회전기 고정자 권선의 부분방전 계측 시 주변 신호 관계를 고려한 노이즈 제거기법)

  • Shin, Hee-Sang;Cho, Sung-Min;Kang, Chul;Kang, Dong-Sik;Cho, Kuk-Hee;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.17-24
    • /
    • 2008
  • Recently, the importance of supplying the reliable electric power is increasing. therefore, the importance of diagnosis of power equipments is increasing also. Breaking insulation of stator windings is major cause of faults in high voltage generators. On-line PD (Partial Discharge) detection using Capacitive Coupler at stator windings is used widely to diagnose high voltage generator. However, precise PD(Partial Discharge) detection is impossible if detected signals are mixed with PD and noise signal. In this paper, we analyze detected signals using Capacitive Coupler at 13[kV] hydroelectric generator stator winding and suggest not hardware method but noise elimination algorithm for detecting PD of generator stator winding considering relation of periphery signals.

A Study on the Design of Prediction Model for Safety Evaluation of Partial Discharge (부분 방전의 안전도 평가를 위한 예측 모델 설계)

  • Lee, Su-Il;Ko, Dae-Sik
    • Journal of Platform Technology
    • /
    • v.8 no.3
    • /
    • pp.10-21
    • /
    • 2020
  • Partial discharge occurs a lot in high-voltage power equipment such as switchgear, transformers, and switch gears. Partial discharge shortens the life of the insulator and causes insulation breakdown, resulting in large-scale damage such as a power outage. There are several types of partial discharge that occur inside the product and the surface. In this paper, we design a predictive model that can predict the pattern and probability of occurrence of partial discharge. In order to analyze the designed model, learning data for each type of partial discharge was collected through the UHF sensor by using a simulator that generates partial discharge. The predictive model designed in this paper was designed based on CNN during deep learning, and the model was verified through learning. To learn about the designed model, 5000 training data were created, and the form of training data was used as input data for the model by pre-processing the 3D raw data input from the UHF sensor as 2D data. As a result of the experiment, it was found that the accuracy of the model designed through learning has an accuracy of 0.9972. It was found that the accuracy of the proposed model was higher in the case of learning by making the data into a two-dimensional image and learning it in the form of a grayscale image.

  • PDF

Influence Regularity of Aluminum, Copper and Stainless-steel on SF6 PD Decomposition Characteristics Components

  • Zeng, Fuping;Luo, Jing;Tang, Ju;Zhou, Qian;Yao, Qiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.295-301
    • /
    • 2017
  • $SF_6$ decomposition products can be used to detect partial discharge (PD), but the metal materials in a PD area can significantly affect $SF_6$ decomposition characteristics. Disregarding the effect of metal materials on such characteristics inevitably result in certain errors when using them to diagnose the internal insulation faults of gas-insulated switchgears. This paper investigates the influence regularity on the main stable decomposition components of $SF_6$ (namely $SO_2F_2$ and $SOF_2$) of the commonly metal materials uesd in GIS, such as aluminum (Al), copper (Cu) and stainless steel (SS). Firstly, an experimental platform is constructed to simulate $SF_6$ decomposition under a PD area, and the influence regularities of Al, Cu and SS on the concentration, formation rate and saturation time of $SO_2F_2$ and $SOF_2$ are obtained. Secondly, the influence mechanism of Al, Cu and SS are preliminary explored combined with the chemical activity of the metal materials.

A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery (고압 전기설비 부분방전시험을 위한 노이즈 저감방안)

  • Lee, Young-Jun;Park, Kwang-Ha;Choi, Hyung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF

A Study on the Condition Monitoring for GIS Using SVD in an Attractor of Chaos Theory

  • J.S. Kang;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.33-41
    • /
    • 2004
  • Knowledge of partial discharge (PD) is important to accurately diagnose and predict the condition of insulation. The PD phenomenon is highly complex and seems to be random in its occurrence. This paper indicates the possible use of chaos theory for the recognition and distinction concerning PD signals. Chaos refers to a state where the predictive abilities of a systems future are lost and the system is rendered aperiodic. The analysis of PD using deterministic chaos comprises of the study of the basic system dynamics of the PD phenomenon. This involves the construction of the PD attractor in state space. The simulation results show that the variance of an orthogonal axis in an attractor of chaos theory increases according to the magnitude and the number of PDs. However, it is difficult to clearly identify the characteristics of the PDs. Thus, we calculated the magnitude on an orthogonal axis in an attractor using singular value decomposition (SVD) and principal component analysis (PCA) to extract the numerical characteristics. In this paper, we proposed the condition monitoring method for gas insulated switchgear (GIS) using SVD for efficient calculation of the variance. Thousands of simulations have proven the accuracy and effectiveness of the proposed algorithm.

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line (전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Park, Choon-Hyun;Cho, I-Gon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

Breakdown Voltage and Partial Discharge Characteristics at the Simulated Interface in a Prefabricated Joint for Ultra High Voltage Cable (초고압용 조립형 접속함 모의계면에서 압력에 따른 절연파괴 및 부분방전 특성)

  • Kim, J.N.;Baek, J.H.;Shin, D.S.;Lee, C.Y.;Kim, C.S.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1099-1101
    • /
    • 1999
  • PJB(Prefabricated Joint Box) is consisted of three major components ; an epoxy unit, a stress relief cone and a spring unit. The insulation structure of PJB is maintained by the interfacial pressure, and the dielectric performance at the interface depends on the interfacial pressure which is regarded as the most important factor for preventing breakdown failure. This experiment was performed to investigate breakdown voltage characteristic and partial discharge patterns under the controlled pressure conditions at the simulated interface. Finally, this paper presents the optimal pressure conditions at the interface by analyasing the PD patterns.

  • PDF

The Characteristic of Frequency Spectrum of Electromagnetic Waves Radiated from Discharge in Air (대기중 방전진전에 따른 방사전자파의 주파수 스펙트럼 특성)

  • Park, Kwang-Seo;Lee, Sang-Hoon;Ju, Jae-Hyun;Choi, Byoung-Ju;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2245-2247
    • /
    • 1999
  • Insulation diagnosis techniques of power equipments for the stable power supply and prevention from accidents are of high importance. Diagnosis techniques is able to prevent from large accidents before they happen by finding signs of the accidents. From this point of view, this paper simulated discharge progress and partial discharge using needle-plan electrode system in air, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study. the new method was introduced for measurement and analyzation of the radiated electromagnetic waves in accordance with discharge progress in air. Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress were possible.

  • PDF