• 제목/요약/키워드: Pad recovery

검색결과 50건 처리시간 0.026초

레일패드의 강성이 자갈궤도 침하에 미치는 영향 연구 (A study on the Settlement of Ballasted Track according to Various Rail-Pad Stiffness)

  • 최진유;김은;황만호;조수익
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.249-255
    • /
    • 2010
  • Ballasted track is under the circumstance of repetition of deterioration and recovery. Track deterioration is presented as track irregularity or settlement, and dynamic force subjected to track is one of major cause of the deterioration. The dynamic force is determined from the dynamic interaction between track and vehicle. Rail-pad stiffness is one of the factor affects track dynamic property. In this study, the relationship between rail-pad stiffness and track settlement was investigated. Dynamic forces according to various rail-pad stiffness was obtained from the dynamic vehicle-track interaction analysis using DARTS-NL. Track settlement was calculated by substitution the dynamic forces into various formulas for track settlement. From the result of analysis, it was known that the track settlement is increased about 6% when the rail-pad stiffness rise about twice. And this result leads that there is only a little relationship between rail-pad stiffness and track settlement.

  • PDF

Novel cystography parameter to predict early recovery from urinary continence after radical prostatectomy for prostate cancer: a retrospective study

  • Yeong Uk Kim
    • Journal of Yeungnam Medical Science
    • /
    • 제40권3호
    • /
    • pp.252-258
    • /
    • 2023
  • Background: The purpose of this study was to investigate whether postoperative cystography findings can predict early and longterm recovery from incontinence after radical prostatectomy (RP), compared with the other cystography parameters. Methods: I retrospectively reviewed 118 patients who underwent robot-assisted RP (RARP) for localized prostate cancer at single institution between January 2016 and April 2021. One hundred and seven patients were included in the study. Postoperative cystography was routinely performed 7 days after surgery. The bladder neck to pubic symphysis ratio, vesicourethral angle, and bladder neck anteroposterior length (BNAP) ratio (the bladder neck-posterior margin distances divided by the anteroposterior lengths) were evaluated. Continence was defined as cessation of pad use. The association between these variables and urinary incontinence was also analyzed. Results: The urinary incontinence recovery rates 1, 3, 6, and 12 months after RARP were 43.92%, 66.35%, 87.85%, and 97.19%, respectively. Multivariate logistic regression analysis demonstrated that a lower BNAP ratio and wider vesicourethral angle were significantly associated with continence restoration at 1, 3, and 6 months after surgery. In addition, in terms of days of pad usage, lower BNAP ratio, wider vesicourethral angle, and bladder neck preservation were significantly associated with recovery from urinary incontinence within 12 months as assessed by Cox proportional hazard analysis. Conclusion: This study demonstrated that vesicourethral angle and BNAP ratio were independent predictors of early recovery from post-prostatectomy incontinence. I suggest that both the sagittal and coronal views of postoperative cystography help anticipate early continence restoration after RARP.

면직물의 저$\cdot$Formaldehyde D.P. 가공 (Low Formaldehyde Release D.P. Finish on Cotton Fabrics)

  • 김성련;류효선;노형은
    • 한국의류학회지
    • /
    • 제10권3호
    • /
    • pp.71-81
    • /
    • 1986
  • In order to control the formaldehyde release from D.P. finished fabric, cotton fabric was padded in DMDHEU resin bath containing either $Zn(NO_3)_2$ or $MgCl_2$ catalyst and a form-aldehyde scavenger like Glycerol, Sorbitol, Formamide, Polyvinyl alcohol (PVA, n= 2000) or diols, then dried and cured. The results are as follows : 1. When Lewis acid catalyst like $Zn(NO_3)_2$ or $MgCl_2$ was added in pad bath, the fabric finished with $Zn(NO_3)_2$ catalyst released the lower formaldehyde than with $MgCl_2$. 2. When the effect of pad bath pH was examined with varying the kinds of catalyst and the scavenger, it was found that the pad bath pH influenced on the amount of formaldehyde release and the optimum pad bath pH is at 4.3. Especially, in case of finishing at pad bath pH 4.3 with adding Formamide, the amount of formaldehyde release was decreased by about $45\~$35\%$ with $Zn(NO_3)_2$, while by about $20\~$45\%$ with $MgCl_2$ catalyst. In case of varying the concentration of a scavenger (Formamide), $1\%$ concentration of a scavenger was found to be the optimum level ana the higher the curing temperature up to $180^{\circ}C$, the lesser the amount of formaldehyde release were observed. 3. When the diol was used as scavenger, the amount of formaldehyde release was decreased by about $40\~$50\%$, but the longer the intramolecular length between OH groups, the lessor the amount of decrease of formaldehyde release were observed. 4. When the mixture of scavengers (Formamide and Glycerol) was added in the pad bath, .synergistic effect on formaldehyde release between the two scavengers wasn't observed. 5. The tensile strength of the resin finished fabric was reduced with increasing the pad lath pH and was influenced by the kind of scavengers, and the tensile strength was severely reduced when scavengers, especially Formamide, was added. The wrinkle recovery property is generally improved by resin finish on cotton fabric. When Formamide was added, the wrinkle recovery property is slightly decreased compared with that of the fabrics resin finished without a scavenger, and when polyol was added, the wrinkle recovery property showed almost no change.

  • PDF

다이아몬드 형상에 따른 컨디셔너 디스크의 특성 평가 (The Characterization of the Conditioner Disks with Various Diamond Shapes)

  • 김규채;강영재;유영삼;박진구;원영만;오광호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.563-564
    • /
    • 2006
  • Recently, CMP (Chemical Mechanical Polishing) is one of very important processing in semiconductor technology because of large integration and application of design role. CMP is a planarization process of wafer surface using the chemical and mechanical reactions. One of the most important components of the CMP system is the polishing pad. During the CMP process, the pad itself becomes smoother and glazing. Therefore it is necessary to have a pad conditioning process to refresh the pad surface, to remove slurry debris and to supply the fresh slurry on the surface. A diamond disk use during the pad conditioning. There are diamonds on the surface of diamond disk to remove slurry debris and to polish pad surface slightly, so density, shape and size of diamond are very important factors. In. this study, we characterized diamond disk with 9 kinds of sample.

  • PDF

차동 연결된 Varactor를 이용한 6Gbps CMOS 피드포워드 이퀄라이저 (A 6Gbps CMOS Feed-Forward Equalizer Using A Differentially-Connected Varactor)

  • 문용삼
    • 대한전자공학회논문지SD
    • /
    • 제46권2호
    • /
    • pp.64-70
    • /
    • 2009
  • 0.13-um CMOS 공정을 이용하여 3GHz에서 6.2dB의 gain을 갖는 피드포워드 이퀄라이저를 구현하고 14.7dB의 감쇄를 갖는 7-m SATA 케이블을 통해 6Gbps의 데이터를 에러 없이 복원하였다. 제안한 이퀄라이저 회로는 varactor의 차동 연결을 통해서 기존 이퀄라이저에서 사용되는 varactor 면적의 1/4만을 사용하도록 설계되어 pad-frame에 집적할 수 있을 뿐만 아니라, 높은 동작 주파수 및 3.6mW의 낮은 전력 소모를 유지할 수 있다.

지상변압기의 단락보호장치 특성연구 (Characteristics of Short-Circuit Protector in Pad-Mounted Transformer)

  • 김광화;이우영;선종호;김동명;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1350-1352
    • /
    • 1995
  • This paper discribed the characteristic of I-t cross-over-point between current limited-fuse and explusion fuse(Bay-O-Net Fuse) and fuse protection in pad-mounted transformer that was generated internal faults and the short circuit of secondary side(load side). In the I-t cross-over-point, current limited fuse was melted when transient recovery voltage was raised rapidly.

  • PDF

Metal CMP 용 컨디셔너 디스크 표면에 존재하는 다이아몬드의 형상이 미치는 패드 회복력 변화 (The Pad Recovery as a function of Diamond Shape on Diamond Disk for Metal CMP)

  • 김규채;강영재;유영삼;박진구;원영만;오광호
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.47-51
    • /
    • 2006
  • 디바이스의 고집적화로 인한 다층 배선구조로 인해 초점심도가 중요해짐에 따라 표면의 평탄도가 디바이스에 매우 큰 영향을 주게 되어, 표면의 평탄도를 결정지어주는 CMP(Chemical Mechanical Polishing) 공정이 매우 중요한 요소가 되었다. CMP 공정에는 슬러리, 연마패드, 컨디셔닝 디스크와 같은 소모품들이 사용된다. 이러한 소모품 중 하나인 컨디셔닝 디스크를 이용한 컨디셔닝 공정은 CMP 공정이 끝난 후 패드의 기공과 groove 내에 잔류 하는 화학반응물이나 슬러리와 같은 잔유물들을 컨디셔닝 디스크 표면에 부착되어 있는 다이아몬드를 이용하여 제거 함으로써 연마율을 높이고, 연마 패드의 수명을 증가 시켜주는 역할을 한다. 컨디셔닝 공정을 실시함으로써 연마 패드의 수명이 연장되기 때문에 경제적인 부분에서도 큰 이점을 가지게 된다. 본 연구에서는 이러한 CMP 공정에서 중요한 역할을 하는 소모품 중 하나인 컨디셔닝 디스크 표면에 존재하는 다이아몬드의 밀도, 형상 그리고 크기에 따라 연마 패드의 회복력 변화를 알아봄으로써 효율적인 컨디션닝 디스크의 특성을 평가해 보았다.

  • PDF

발뒤꿈치의 재건 시에 사용할 수 있는 다양한 피판술 (Various Modalities of Flap Surgery in Heel Pad Reconstruction)

  • 정연익;이동원;윤인식;나동균;이원재
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.415-420
    • /
    • 2011
  • Purpose: The reconstruction of a soft tissue defect of the heel pad can be challenging. One vital issue is the restoration of the ability of the heel to bear the load of the body weight. Many surgeons prefer to use local flaps or free tissue transfer rather than a skin graft. In this study, we evaluated the criteria for choosing a proper flap for heel pad reconstruction. Methods: In this study, 23 cases of heel pad reconstruction were performed by using the flap technique. The etiologies of the heel defects included pressure sores, trauma, or wide excision of a malignant tumor. During the operation, the location, size and depth of the heel pad defect determined which flap was chosen. When the defect size was relatively small and the defect depth was limited to the subcutaneous layer, a local flap was used. A free flap was selected when the defect was so large and deep that almost entire heel pad had to be replaced. Results: There was only one complication of poor graft acceptance, involving partial flap necrosis. This patient experienced complete recovery after debridement of the necrotic tissue and a split thickness skin graft. None of the other transferred tissues had complications. During the follow-up period, the patients were reported satisfactory with both aesthetic and functional results. Conclusion: The heel pad reconstructive method is determined by the size and soft-tissue requirements of the defect. The proper choice of the donor flap allows to achieve satisfactory surgical outcomes in aesthetic and functional viewpoints with fewer complications.