• Title/Summary/Keyword: Overhead power line

Search Result 221, Processing Time 0.037 seconds

Technical Feasibility Study on Live-line Maintenance Robot System for Overhead Distribution Lines (가공 배전선로 활선 정비 로봇 시스템의 기술 타당성 검토)

  • Joon-Young, Park;Yoon-Geon, Lee;Young-Sik, Jang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 2022
  • The distribution live-line work method is an operation method of working in a state in which electricity flows through overhead distribution lines to minimize inconvenience to electric customers due to power failure. In June 2016, to strengthen the safety of electrical workers, Korea Electric Power Corporation announced that it would in principle abolish the rubber glove method, in which workers wore protective equipment such as rubber gloves and performed their maintenance work. In addition, KEPCO announced that it would develop a short-range live working method using smart sticks and an advanced live-line maintenance robot system where workers work without touching wires directly. This paper is a preliminary study for the development of the live-line maintenance robot system, and deals with the results of analyzing the technical feasibility of whether the live works performed by workers can be replaced by robots or not.

The Study for Analysis and Prevention Measure of Overhead Transmission Line Fault with Birds (조류에 의한 가공송전선로의 고장분석 및 예방대책 고찰)

  • Jung, Si-Hwan;Kang, Cheul-Won;Kim, Wan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.96-98
    • /
    • 2006
  • Recently major power outages are increased, because of transmission line fault by birds. Therefore, after finding out the problem of the current prevention measure for the super high voltage transmission Line in Korea and analyzing the protection measure of other foreign power companies for the transmission facilities fault by birds, this paper describes an effective device for power line fault protection by birds which has no legal problem and also protects birds. The described prevention measure of power outage by birds in this paper, has a special feature that is able to be installed on the current overhead transmission facilities without a replacement or change.

  • PDF

Study on the Estimation of Seasonal Ambient Current for the Application of Ambient Adjusted Line Rating(AAR) in Overhead Transmission Lines Using Risk Tolerance(RT) Method (가공송전선로의 AAR 적용 시 Risk Tolerance 분석을 이용한 계절별 최대 허용전류 산정 및 적용에 관한 연구)

  • Lee, Jaegul;Bae, Youngjae;Song, Jiyoung;Shin, Jeonghoon;Kim, Yonghak;Kim, Taekyun;Yoon, Yongbeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.7-15
    • /
    • 2017
  • Ambient Adjusted line Rating(AAR) method for overhead transmission lines considering Risk Tolerance(RT) was proposed in this paper. AAR is suitable for system operators to plan their operation strategy and maintenance schedule because this can be designed as a seasonal line rating. Several candidate transmission lines are chosen to apply the proposed method in the paper. As a result, it is shown that system reliability was significantly enhanced through maximizing transfer capability, solving the system constraints.

Arc Fusion Protection of Covered Conductors Using AFPD (섬락 단선 방지 장치에 의한 피복 절연 가공배전 선로의 유도뢰애 의한 단선 방지)

  • Lee, Yong-Han;Jung, Dong-Hak;Ha, Bok-Nam;NamKung, Do;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.800-802
    • /
    • 1997
  • After flashover occurs on the overhead distribution line by lighting strokes(direct or induced), the power frequency arc current continues. If lightning flashover occurs on the overhead lines using covered conductors, the power frequency art current with fixed path overheats the conductor, and arc fusion fault can be occurred. There are two categories protecting or reducing methods of arc fusion faults caused by lightning stokes. - Reducing lightning flashover rate : G/W, LA, etc. - Protection by AFPD(Arc Fusion Protection Device) : power follow current interruption. This paper presents lightning surge phenomena on overhead distribution lines and protecting performance of arc fusion Protection devices to the lightning strokes nearby overhead line.

  • PDF

Calculation of Radiative Electric Field Intensity of Overhead Medium-Voltage Power lines for Power Line Communication (전력선통신을 위한 고압 배전선로의 방사전계강도 계산)

  • Chun Dong-wan;Park Young-jin;Kim Kwan-ho;Shin Chull-chai
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.12A
    • /
    • pp.1136-1146
    • /
    • 2005
  • In this paper, the radiative electric field intensity due to the communication signal and conductive noise is calculated in overhead medium voltage power lines for power line communication. The input impedance is calculated by means of 2 port equivalent model of medium voltage power line network and basic transmission line theory. And then, currents is calculated by calculated input impedance and finally, the emissive electric field is calculated. The input impedance appears like a standing wave form with a fixed cycle because high reflection at the input terminal due to the characteristic impedance of medium voltage power line is very large. A calculated current and radiative electric field also appears like this form. From the measurement results, the measured results are very similar to the calculated results.

Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line (초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석)

  • Lim, Jae-Seop;Shin, Koo-Yong;Lee, Dong-Il;Ju, Mun-No;Yang, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network (한국전력 노후 가공송전선의 동적송전용량에 대한 재평가)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.123-129
    • /
    • 2010
  • During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

The Effects of Elastic Modulus Coefficient and Linear Expansion Coefficient of Overhead Conductor on Sag Behavior (가공전선의 이도거동에서 탄성계수와 선팽창계수의 영향)

  • Kim, Byung-Geol;Kim, Shang-Shu;Wang, Yun-Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.954-960
    • /
    • 2008
  • The effects of elastic modulus coefficient and linear expansion coefficient of overhead distribution power line(ACSR $58 mm^2$) on sag behavior in distribution line have been investigated to clarify the difference between specification and experimental level. The elastic modulus coefficients of Al wire and steel wire were $5,182.6 kgf/mm^2,\;18,348.8 kgf/mm^2$, respectively Therefore, the computational composition elastic modulus coefficient of the power line was $7,063.5 kgf/mm^2$, while that of experimentally measured was $7681.1 kgf/mm^2$. As a result, we found that elastic modulus coefficient which was experimentally measured was higher than that of computational by 8.7 %. However, when planner designs the sag of disoibution line, the elastic modulus coefficient of power line $8,400 kgf/mm^2$ should be generally adopted. These two different using values lead to the sag difference of 0.62 m. The other results will be discussed.

The Basic Study on Overvoltage of HVDC Transmission Line Using TNA (계통과도전압분석기를 이용한 직류송전선로의 과전압에 대한 기초적 해석)

  • Woo, Jung-Wook;Shim, Jeong-Woon;Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1810-1812
    • /
    • 1997
  • This paper describes the results of ground fault analysis on HVDC Transmission Line using TNA (Transient Network Analyzer). The maximum overvoltage is about 1.7 p.u. in the case of single line to ground fault on the overhead transmission line. When the cable is linked to the end of the overhead transmission line, the maximum overvoltage is about 1.58 p.u..

  • PDF

A Study on Acquisition of Overhead Line Location Information of Pantograph for E-Highway (E-Highway를 위한 팬터그래프의 가공선 위치정보 취득에 관한 연구)

  • Gwang-Cheol Song;Jun-Jae An;Tuan-Vu Le;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.915-923
    • /
    • 2023
  • As environmental regulations on carbon emissions are strengthened worldwide, the existing internal combustion engine-centered automobile industry is being reformed. In particular, large buses and large cargo trucks are pointed out as one of the main causes of environmental destruction due to excessive carbon emissions. The E-Highway power collection system, which has recently been proposed as a solution, uses the vehicle's battery as a backup power source or regenerative braking, depending on whether the pan head of the pentograph installed in the vehicle is in contact with the overhead line. It is used to store the excess energy generated. However, wear through contact due to continuous contact reduces the current collection effect and causes failure. In this paper, by using the current difference, the horizontal position information of the panhead in contact with the overhead line is acquired, thereby reducing the abrasion of the conductor and the panhead Make it possible to follow the overhead line. The position estimation method proposed in this paper simply configures a device that can detect the position of the overhead line of the pantograph by the difference in resistance. It is economical and has the advantage of reducing the volume. The characteristics of the pantograph estimating the location of overhead lines were analyzed using the difference between the two currents of the current collector, the feasibility of the positioning estimation system was verified through simulations and experiments.