• Title/Summary/Keyword: Operation Recording

Search Result 152, Processing Time 0.023 seconds

위성발사를 위한 원격측정 지상국시스템 설계에 관한 연구

  • Lee, Sung-Hee;Oh, Chang-Yul;Lee, Hyo-Keun
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.167-178
    • /
    • 2003
  • The design on the Telemetry Ground System for launch of KSLV(Korea Space Launch Vehicle) in the korean Space center has been conducted in this study. For the optimized system design, first of all, the system deployment plan reflecting the topographic and geographic environments of the space center and launch vehicle characteristics has been developed. The RF link budget analysis for the maximum tracking range, requirement for receiving subsystem including antenna subsystem, requirement for data processing subsystem are also analyzed based on the On-Board Telemetry characteristics and launch vehicle parameters. Based on those analysis, telemetry ground system containing tracking/receiving subsystem, recording subsystem and data processing subsystem, timing subsystem, calibration subsystem and monitoring and control subsystem are designed. Futhermore, the analysis for the maximum permissible data latency and communication protocol between each telemetry station and control center are conducted and the entire system is designed so that the major telemetry parameters selected to the best quality are provided in real time to the control center(RCC, RSC) for the launch mission operation.

  • PDF

Intraoperative Monitoring of Motor-Evoked Potentials for Supratentorial Tumor Surgery

  • Lee, Jung Jae;Kim, Young Il;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won;Yang, Seung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.98-102
    • /
    • 2014
  • Objective : The purpose of this study was to assess the feasibility and clinical efficacy of motor evoked potential (MEP) monitoring for supratentorial tumor surgery. Methods : Between 2010 and 2012, to prevent postoperative motor deterioration, MEP recording after transcranial stimulation was performed in 84 patients with supratentorial brain tumors (45 males, 39 females; age range, 24-80 years; median age, 58 years). MEP monitoring results were correlated with postoperative motor outcome compared to preoperative motor status. Results : MEP recordings were stable in amplitude (<50% reduction in amplitude) during surgery in 77 patients (91.7%). No postoperative motor deficit was found in 66 out of 77 patients with stable MEP amplitudes. However, postoperative paresis developed in 11 patients. False negative findings were associated with edema in peri-resectional regions and postoperative bleeding in the tumor bed. MEP decrease in amplitude (>50%) occurred in seven patients (8.3%). However, no deficit occurred postoperatively in four patients following preventive management during the operation. Three patients had permanent paresis, which could have been associated with vascular injury during tumor resection. Conclusions : MEP monitoring during supratentorial tumor surgery is feasible and safe. However, false negative MEP results associated with postoperative events may occur in some patients. To achieve successful monitoring, collaboration between surgeon, anesthesiologist and an experienced technician is mandatory.

A Case Study on Application of Linear Function using Excel (엑셀을 통한 일차함수의 활용에 대한 사례연구)

  • Lee, Kwang-Sang
    • School Mathematics
    • /
    • v.10 no.1
    • /
    • pp.1-22
    • /
    • 2008
  • The purpose of this study is to search the effective teaching-learning program by considering how affect on formation of linear function using Excel. This study was based on qualitative case study. The teaching experiment using Excel executed with five 8th graders' students for second research content. Teaching experiment was performed for two classes. Collecting the data was conducted via observations and interviews with students. The data include audio and video recording of the students' work, students' worksheets and detailed field notes. The conclusions drawn from teaching experiment are as follows: First, when students explored relevancy content of function in Excel environment, formation of concept of function was facilitated by experiencing operation of algebraic formulas, tables and graphs. We could infer that formation of concept was effected by conjecture activity and iterative process of feedback through Excel environment. Second, the students explored the changes very interestingly making algebraic formulas and presenting tables and graphs. The students were familiarized with observation on algebraic formulas, graphs and tables concurrently. Also, they tried to look for general rules through inductive observation. According to this study, we noticed that exploration teaming environment using Excel could supplement paper-and-pencil environment.

  • PDF

Development of Case-based Multimedia Learning Contents for Preventing Malpractice in Operating Room (수술실 간호오류 예방을 위한 사례중심 멀티미디어 학습콘텐츠 개발)

  • Park, Ji Myung;Hwang, Seon Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.522-532
    • /
    • 2016
  • Purpose: This study was conducted to develop case-based self-learning multimedia contents for preventing malpractice that frequently occurred among nurses working in the operating room. Methods: Based on the learning needs of operating room nurses, real case reports, and literature reviews, the case-based multimedia learning contents were developed according to the instructional design procedure. The assessment of learning needs was performed by the combination of surveys using structured questionnaire and of interviews for 40 operating room nurses. Results: The learning contents included four learning modules with real malpractice cases from the areas of operating preparation, nursing skills during operation, environmental management of operating room, and patient safety and observation-related. The 80 minute long case-based multimedia learning contents were finally developed after content validity tests from clinical experts. Each module contained photos, sounds and flash animation with voice recording on the contents of nursing error cases and standardized protocols. Conclusion: The developed multimedia learning contents based on real error cases in this study can be utilized as an educational hands-on training materials for nurses to prevent malpractice in the operating room.

A Study on the Development of Playback Control Software for Mark5B VSI System

  • Oh, S.J.;Yeom, J.H.;Roh, D.G.;Chung, H.S.;Kim, K.D.;Cappallo, Roger
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.107-116
    • /
    • 2010
  • We developed the playback control software for a high-speed playback system which is a component of the Korea-Japan Joint VLBI Correlator (KJJVC). The Mark5B system, which is a recorder and playback system used in the Korean VLBI Network (KVN), has two kinds of operation mode. That is to say, the station unit (SU) mode, which is for the present Mark4 system, and the VSI mode, which is for the new VLBI standard interface (VSI) system. The software for SU is already developed and widely used in the Mark4 type VLBI system, but the software for VSI has only been developed for recording. The new VLBI system is designed with a VSI interface for compatibility between different systems. Therefore, the playback control software development of the VSI mode is needed for KVN. In this work, we developed the playback control software of the Mark5B VSI mode. The developed playback control software consists of an application part for data playing back, a data input/output part for the VSI board, a module for the StreamStor RAID board, and a user interface part, including an observation time control part. To verify the performance of developed playback control software, the playback and correlation experiments were performed using the real observation data in Mark5B system and KJJVC. To check the observation time control, the data playback experiment was performed between the Mark5B and Raw VLBI Data Buffer (RVDB) systems. Through the experimental results, we confirmed the performance of developed playback control software in the Mark5B VSI mode.

Rig Tester Development for the Performance Validation of a Piston Oil Cooling Gallery (피스톤 오일 냉각 유로의 성능 검증을 위한 리그 시험기 개발)

  • Chun, Sang-Myung;Lee, Jeong-Keun;Joo, Dae-Heon;Ryu, Kwan-Ho;Ha, Dae-Hong
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.387-398
    • /
    • 2009
  • The operation condition of recently designed pistons for high power and high speed diesel engine become more severe due to the increment of combustion pressure and temperature. So, in order to overcome high temperature, the application of the mono-metal cast aluminum alloy piston featuring an enclosed cast-in open cooling gallery has increased. In this research, it is developed a PCJ (piston cooling jet) rig tester, described the test procedure and validated the performance of sample piston cooling gallery design. Then the test rig will be used for developing the design technology of piston cooling gallery. The test rig is composed with oil reservoir and pumping system, oil jet system, piston fixing and moving system, collecting oil measuring system, and data measuring and recording system. It will be measured collecting efficiencies under conditions of a few piston positions, oil jet pressures and oil viscosities for a piston cooling gallery. Furthermore, the PCJ rig tester will be used for the optimum design of the oil cooling gallery which being applied to increase the cooling efficiency of pistons in diesel engines satisfying the EURO V emission regulation and the more.

An Iterative Weighted Mean Filter for Mixed Noise Reduction (복합 잡음 저감을 위한 반복 가중 평균 필터)

  • Lee, Jung-Moon
    • Journal of Digital Contents Society
    • /
    • v.18 no.1
    • /
    • pp.175-182
    • /
    • 2017
  • Noises are usually generated by various external causes and low quality devices in image data acquisition and recording as well as by channel interference in image transmission. Since these noise signals result in the loss of information, subsequent image processing is subject to the corruption of the original image. In general, image processing is performed in the mixed noise environment where common types of noise, known to be Gaussian and impulse, are present. This study proposes an iterative weighted mean filter for reducing mixed type of noise. Impulse noise pixels are first turned off in the input image, then $3{\times}3$ sliding window regions are processed by replacing center pixel with the result of weighted mean mask operation. This filtering processes are iterated until all the impulse noise pixels are replaced. Applied to images corrupted by Gaussian noise with ${\sigma}=10$ and different levels of impulse noise, the proposed filtering method improved the PSNR by up to 12.98 dB, 1.97 dB, 1.97 dB respectively, compared to SAWF, AWMF, MMF when impulse noise desities are less than 60%.

Evaluation of Phase Transition Behavior of Ge2Sb2Te5 Thin Film for Phase Change Random Access Memory (상변환 메모리의 응용을 위한 Ge2Sb2Te5 박막의 상변환 거동 평가)

  • Do, Woo-Hyuk;Kim, Sung-Soon;Bae, Jun-Hyun;Cha, Jun-Ho;Kim, Kyung-Ho;Lee, Young-Kook;Lee, Hong-Lim
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.1 s.296
    • /
    • pp.18-22
    • /
    • 2007
  • The phase transition behavior of $Ge_2Sb_2Te_5$ (GST) thin film, which is a candidate material of recording layer for phase change random access memory (PRAM), has been evaluated using an in-situ reflectance measurement method. The experimental data have been analyzed by using johnson-mehl-avrami-kolomogorov (JMAK) model. JMAK model can be used only in isothermal state. However, temperature changes with time during the operation of PRAM. To apply JMAK equation to PRAM simulation, it has been assumed that the temperature increases stepwise and isothermally. By using JMAK equation and assumption for the transient state, the phase transition behavior of GST thin film has been predicted under $3^{\circ}C/min$ heating rate in this study. The simulation result agrees well with the experimental results. Therefore, It can be concluded that JMAK equation can be used far the PRAM simulation model.

Remotely Controllable Smart Mobile System Using Arduino and Raspberry Pi for Infants

  • Park, Hyun-Wook;Shin, Young-Weon;Kim, Jin-Yeob;Kong, Ki-Sok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.11
    • /
    • pp.17-25
    • /
    • 2020
  • In this paper, we deal with a system that provides temperature, humidity and fine dust data around infants to parents through Arduino and Raspberry Pi. It controls the operation of the mobiles remotely through applications. Android applications can perform the following functions. First, the infant's surrounding temperature, humidity and fine dust data are received. Second, mobile controls the smart mobile remotely. Third, recording and playing the voices of parents and enhancing the convenience of parenting. Through the experiment of measuring the operating time of the remote control module, it was confirmed that the application can quickly access the system. Existing products on the market do not provide environmental information around the infants and application that has various functions. The system covered in this paper is expected to improve child-rearing convenience by providing parents environmental information around infants, remotely controllable function and convenient functions of the application.

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.