• Title/Summary/Keyword: Operating room temperature

Search Result 226, Processing Time 0.034 seconds

A comparison of resident's behavior of operating air conditioner according to the charge for electric (사용자의 전기요금 부담 여부에 따른 여름철 냉방기 사용 특성의 비교)

  • Kwon, Suh-Hyun;Choi, Yoo-Rim;Chun, Chung-Yoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.301-305
    • /
    • 2006
  • An electrical bill is one of the various factors that influence on energy use of residents. This study focused on electrical bills and searched that whether electrical bills affect resident behavior of operating air conditioner and their controlled indoor climate. We surveyed two groups for field study ; the one is residents who live in a studio apartment in Seoul and they are charged for electric as energy consumption they used, and the other is residents who live in a university dormitory and they are not charged for their energy consumption. We measured how long they used the air conditioner for cooling, on/off temperature of air conditioner and room temperature for these two groups. Residents were interviewed about their cooling needs, decisions about when to turn on their air conditioner and so on. We found that dormitory group has much amount of time used the air conditioner than studio apartment group and there are differences of room temperature between two groups when they turn on or off air conditioner. The result shows that perception of money affects resident behavior of operating air conditioner and their acceptable thermal range.

  • PDF

Frictional Characteristics of Stainless Steel Lubricated with Pressurized Water at High Temperature (고온 고압하에서 물로 윤활되는 스테인레스 강의 마찰 특성)

  • 이재선;김지호;김종인
    • Tribology and Lubricants
    • /
    • v.19 no.1
    • /
    • pp.21-25
    • /
    • 2003
  • The 440C stainless steel is used for ball bearings and bevel gears in the control rod drive mechanism for the integral reactor, SMART. The friction characteristics of 400C stainless steel a investigated in sliding motion using the reciprocating tribometer which can simulate the operating conditions of the control rod drive mechanism. Highly purified water is used as lubricant, and the water is heated and pressurized in the autoclave. Friction force on the reciprocating specimens is measured by the load cells and transformed into friction coefficient. It is verified that frictional characteristic of the 440c steel is not drastically changed up to operating temperature and variation of friction coeffcient at operating temperature from room temperature to 160$^{\circ}C$ is within 5%.

Experimental study of water membrane sprinkler in fire prevention block (방화구획과 수막설비 관한 연구)

  • Oh, Chang-Hui;Son, Jang-Yeol;Kim, Hwa-Jung;Kim, Sang-Uk;Choi, Jin
    • Fire Science and Engineering
    • /
    • v.2 no.3
    • /
    • pp.3-9
    • /
    • 1988
  • This paper is study about establishment with water membrane sprinkler in fire prevention block of special Building. The testing program was directed toward investigating the temperature of fire and adjacent room. The results of fire test indicated that under the test conditions in this study, adjacent room temperature is very low in compare with fire room temperature at operating of water membrane sprinkler. Therefore, if exclusion of smoking can be soluted, substitution of water membrance sprinkler in fire resistance wall of fire prevention block is possible.

  • PDF

Sensing performances of Semiconducting Carbon Nanomaterials based Gas Sensors Operating at Room Temperature (반도체 탄소 나노재료 기반 상온 동작용 가스센서)

  • Choi, Sun-Woo
    • Ceramist
    • /
    • v.22 no.1
    • /
    • pp.96-106
    • /
    • 2019
  • Semiconducting carbon-based nanomaterials including single-walled carbon nanotubes(SWCNTs), multi-walled CNT(MWCNTs), graphene(GR), graphene oxide(GO), and reduced graphene oxide(RGO), are very promising sensing materials due to their large surface area, high conductivity, and ability to operate at room temperature. Despite of these advantages, the semiconducting carbon-based nanomaterials intrinsically possess crucial disadvantages compared with semiconducting metal oxide nanomaterials, such as relatively low gas response, irreversible recovery, and poor selectivity. Therefore, in this paper, we introduce a variety of strategies to overcome these disadvantages and investigate principle parameters to improve gas sensing performances.

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.

Study on Leak Rate of SCC Degraded Alloy 600 Tubings of PWRs

  • Hwang, Seong Sik;Kim, Joung Soo;Kasza, Ken E.;Park, Jangyul
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.233-239
    • /
    • 2004
  • Primary water stress corrosion cracking of steam generator tubings occur on many tubes in pressurized water reactors(PWRs), and they are repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to know the leak behavior of the tubes, which have stress corrosion cracks. Crack development tests were carried out on the tubes at room temperature, and leak rate and burst pressure were measured on the degraded tubes at room temperature and a high temperature. No leakage was detected on the tubes where 100 % through wall crack developed, at 1560 psi, which is an operating pressure difference of pressurized water reactors(PWRs). In some tests, leak rates of the tubes increased with time at a constant internal water pressure. A test tube showed a very small amount of leakage at 2700 psi in a high temperature pressure test at $282^{\circ}C$, but it disappeared after the pressure increased slightly. Even cracks are 100 % through wall, they need to open in order to reach a certain amount of leak rate at the operating pressure difference.

Development of comfort algorism for Indoor temperature chagne in Heating System (변동환경 대응을 위한 난방System의 쾌적 알고리즘 개발)

  • Kim, Dong-Gyu;Jeong, Yong-Hyun;Kum, Jong-Soo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.229-235
    • /
    • 2006
  • This study investigated physiology and psychological response of subjects, when heat pump was operated long time within comfort temperature range. Eight subjects were participated for the experiment. Their age was from 22 to 25 years old. The results of this experiment will propose basic data for improving comfort control algorithm in fluctuating environment by using heat pump. When indoor temperature was controlled by heat pump, the conclusion was as follows. 1) When votes of subjects was considered, the thermal comfort neutrality or lower range helped formation of comfort sensation for subjects. 2) When room temperature was lower, thermal comforts of shoulder, knee and foot with subjects thermal comfort showed high correlation. And when room temperature was higher, thermal comfort of face region with subjects thermal comfort showed high correlation. 3) The necessity of temperature change after 50 minutes from initially operating heat pump demands the additional analysis against the physiological signal.

High Temperature Characterization of Accumulation-mode Pi-gate pMOSFETs (고온에서 accumulation-mode Pi-gate p-MOSFET 특성)

  • Kim, Jin-Young;Yu, Chong-Gun;Park, Jong-Tae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.1-7
    • /
    • 2010
  • The device performances of accumulation-mode Pi-gate pMOSFETs with different fin widths have been characterized at high operating temperatures. The device fin height is 10nm and fin widths are 30nm, 40nm, and 50nm. The variation of the drain current, threshold voltage, subthreshold swing, effective mobility, and leakage current have been investigated as a function of operating temperatures. The drain current at high temperature is slightly larger than at room temperature. The variation of the threshold voltage as a function of the operating temperature is smaller than that of the inversion-mode MOSFETs. The effective mobility is decreased with the increase of operating temperature. It is observed that the effective mobility is enhanced as the fin width decreases.