• 제목/요약/키워드: Noise Rating

검색결과 156건 처리시간 0.024초

바닥충격음 차단성능 평가방법의 상호비교 (Comparison of Rating Methods for the Floor Impact Sound Insulation Performance)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF

발전소 주변압기 운전중 진동 기준치 설정에 관한 연구

  • 이욱륜;이준신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.587-592
    • /
    • 2005
  • Main transformer's integrity assessment in nuclear power plant is estimated by the electrical test of electrical core and wire and the chemical analysis of insulating oil. Mechanical test or analysis has not been so far. So this study makes it with the vibration velocity rating. The vibration velocity rating in main transformer which is based on the real data of vibration velocity measurement under operating and other machinery vibration code such as ISO code is renewed.

  • PDF

공동주택 경량바닥충격음 측정불확도 추정에 관한 연구 (A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors)

  • 고종철;이종인;김현배;이철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

층상배관 배수시스템의 소음 특성 평가 (Noise Characteristics of Plumbing System with Wall Hanging Unit)

  • 박철용;김상훈;장동운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1421-1424
    • /
    • 2006
  • Recently Requirement of indoor environment is increased in APT. Among indoor noises of APT, noise of plumbing system in bathroom is very serious problem except of floor impact noise. Plumbing system with wan hanging unit make a good grade and recognition in rating noise of bathroom in grade of house rating. But it is hard to find a data which are measured in APT built. In this study, the effect of noise reduction is checked by measuring the noise of plumbing system with wall hanging unit that is built. As result the upper household's Peak sound level is measured 80dB(A), the under household's peak sound level is measured 40dB(A).

  • PDF

배경소음이 다른 동일 건물내 사업장의 소음 수인한도 및 인지 정도에 관한 연구 (An study on the annoyance and loudness for the different background noises in complex building)

  • 이태강;장길수;김선우
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.109-114
    • /
    • 2010
  • There are many business in complex building, and recently noise claims have increased in those buildings. It is one of the most desirable methods reducing the noise level to establish the noise criteria considering the admittable noise level between the source and receiving room, which are to be derived from the subjective response in the real conditions. Because the degree of annoyance and loudness for the intruding noises in complex building could be changed with background noise level, it is suggested to be researched the relationship between the noise levels and subjective response. In this study, the subjective response for three different background levels in receiving business or rooms were investigated for the typical eight business noise source including aerobic music. The results can be summarized as follows. In conditions of low background noise level(40 dB(A)), there is a tendency of intentionally attention situation (listening) in a subjective test. The other hand in conditions of relatively high background noise level(50 dB(A)), there is a unconscious situation (heraing). As the degree of moderately heard or annoyed in SD rating scale means that the noise is easily recognized in neighboring shops, usually the limit of noise criteria were decided on this rating point, so it will be reasonable to be adopted the criteria rating scale as slight heard or annoyed degree (SD criteria 3).

급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구 (An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom)

  • 이태강;고광필;최은석;김항;김선우
    • 한국소음진동공학회논문집
    • /
    • 제17권3호
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Leq, Lr, TNI 평가법에 의한 부산시 주요 상가변의 소음도 분석 (An Analysis on Traffic Noise at Pusan Shopping Districts by Leq, Lr, TNI Ratings)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제16권1호
    • /
    • pp.9-19
    • /
    • 1990
  • To evaluate the degree of traffic noise at the main shopping districts, 30 sites, in Pusan and produce the basic data of traffic noise counterplan, this research was conducted. Noise rating methods utilized were Leq(equivalent continuous sound level), Lr (rating sound level) and TNI (traffic noise index). As the results, all sites passed beyond Korean Environmental Noise Standard 70 dB(A) in Leq and 46.7% sites fell under 'widespread complaints'step, 40.0% 'threat of community' action'step, 13.3% 'vigorous community action'step by Lr ratings, and 30.0% sites were over acceptable TNI criteria of 74. Therefore, traffic noise at Pusan shopping districts was very severe.

  • PDF

공동주택 외부소음 현장측정방법 (Field Measurements of Exterior Noise at Apartment Houses)

  • 송민정;정성수;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.359-362
    • /
    • 2005
  • Road traffic noise level and railway noise level are important factors on apartment inhabitant's comforts. The measurement methods which noted by Ministry of Construction & Transportation(MOCT) and Ministry of Environment(ME) are used for measurement of exterior noise at apartment houses. But these methods are out of date because the height of apartment houses have increased dramatically and owing to the sampling methods of the measurement time interval, rating values are induced differently due to sampling methods. In this study, the sound level of each floor of apartment houses is measured and compared. And rating value due to sampling methods are compared. As a result, the KS outline of 'Field Measurement of Exterior Noise at Apartment Housess' is suggested.

  • PDF

시트 벨트 인출 소음 평가 기술 및 인덱스 개발 연구 (Development of Seat Belt Pulling Noise Index and Evaluation System Research)

  • 조혜영;이상권;강희수;손주환
    • 한국자동차공학회논문집
    • /
    • 제23권2호
    • /
    • pp.185-190
    • /
    • 2015
  • The purpose of this study is developing the quantify the seat belt pulling Noise index and evaluation method. This paper presents the objective method to evaluate the emotional feeling about the pulling Noise of the seat belt. The physical quantification is required to objectively evaluate the emotional feeling of the pulling Noise. This is called the "Noise metric." The Noise metric is should correlated to the subjective rating of the pulling Noise. The pulling Noise index is developed throughout the linear regression of the Noise metric and the subjective rating. The developed index is used for the objective evaluation of the emotional feeling about the pulling Noise of a seat belt throughout the modification of seat belt components.

평가방법을 고려한 공동주택 바닥충격음 평가어휘 선정에 관한 연구 (A Study on the Proper Vocabularies for Evaluating Floor Impact Sound in Apartment Houses Considering Rating Methods)

  • 이재연;김선우;송민정
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.626-631
    • /
    • 2004
  • In this study, the extracted words from the former study such as annoying, loud, noisy, irritating, disagreeable, strident, disturbed, and dissonant are given to subjects in psycho acoustic experiment lab. And then, correlation analysis between the words and floor impact noise rating method were carried out. As a result of this study followings are suggested ‘Annoying’ is the word most accurately expressing the subjects’ unpleasant feeling of domestic floor impact noise. The results of this study could be basic materials for psycho acoustic experiments for criteria on floor impact noise and Sound Classification on Floor Impact Sound Insulation Performance.