• 제목/요약/키워드: Natural Vibration analysis

검색결과 1,925건 처리시간 0.026초

전동-발전기의 방진 마운트에 기인한 공진현상 및 동특성 규명 (Dynamic characteristic for vibration mount of MG-Set)

  • 유무상;오경환;주인국;김효진;노철우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.816-821
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of generator-motor set. The generator is driven at 1800rpm by induction integral motor. The vibration is below alarm limits, but the dominant frequency of vibration is sub-synchronous and close to that of bearing fault signal in spite of new bearings. To find an mechanism of abnormal vibration, ODS and Modal analysis is carried out. The measured modal characteristics were compared with those of FE Analysis. The ODS mode at rated speed is consistent with system natural frequency mode that is excited by bearings. To reduce vibration level, the isolation mount at system base is changed with new rubber mount for lower natural frequency.

  • PDF

다물체계의 평형위치에서 고유진동수에 대한 공차해석 (Tolerance Analysis for Natural Frequencies of Multi-body Systems in Dynamic Equilibrium State)

  • 엄승만;최동환;유홍희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.95-100
    • /
    • 2006
  • Tolerance analysis method for natural frequencies of multi-body systems having a equilibrium position is suggested in this paper. To perform the tolerance analysis, the Monte-Carlo Method is conventionally employed. However, the Monte-Carlo Method has some weakness; spending too much time for analysis and having a low accuracy and hard to converge in the numerical unstable area. To resolve these problems, a tolerance analysis method is suggested in this paper. Sensitivity equations of natural frequencies are derived at the equilibrium position. By employing the sensitivity information of mass, damping and stiffness matrices, the sensitivity of natural frequencies can be calculated.

  • PDF

다물체계의 평형위치에서 고유진동수에 대한 공차해석 (Tolerance Analysis for Natural Frequencies of Multi-body Systems in Dynamic Equilibrium State)

  • 엄승만;최동환;유홍희
    • 한국소음진동공학회논문집
    • /
    • 제17권1호
    • /
    • pp.65-71
    • /
    • 2007
  • Tolerance analysis method for natural frequencies of multi-body systems having a equilibrium position is suggested in this paper. To perform the tolerance analysis, the Monte-Carlo Method is conventionally employed. However, the Monte-Carlo Method has some weakness; spending too much time for analysis and having a low accuracy and hard to converge in the dynamical unstable area. To resolve these problems, a tolerance analysis method is suggested in this paper. Sensitivity equations of natural frequencies are derived at the equilibrium position. By employing the sensitivity information of mass, damping and stiffness matrices, the sensitivity of natural frequencies can be calculated.

부분적으로 유체가 채워진 원통형 관내의 외팔보 진동해석 (Vibration Analysis of an Cantilever Beam in Partially Liquid-Filled Cylindrical Pipe)

  • 권대규;유계형;방두열;이성철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1073-1078
    • /
    • 2003
  • This paper presents the vibration characteristics of a cantilever beam in contact with a fluid using a PZT actuator and PVDF film. dynamic behaviors of a flexible beam-water interaction system are examined. The effect of the liquid level on free vibration of the composite beam in a partially liquid-filled circular cylinder is investigated. The coupled system is subject to an undisturbed boundary condition un the fluid domain. In the vibration analysis of a wetted beam. the decoupled analyses between beam and fluid have been conventionally employed by considering first the composite beam vibration in the all and secondly Performing the correction taking account for surrounding fluid effects. That is, this investigation was to look at how natural frequencies, mode shapes. and damping are affected by liquid level variations. The signals from the sensor according to the applied input voltage are digitalized and filtered in order to obtain the dynamic characteristics of the composite beam in contact with fluid. It was found that the coupled natural frequencies decreased with the fluid level for the identical composite beam due to added mass effect. In case of the free-free boundary condition, the natural frequency gently decreased at fluid water level between 20% and 80% in the first tending mode and we found out the bends of stair shape for added mass effect of the fluid.

  • PDF

고층건물의 상시진동계측을 통한 고유진동수 (Natural Frequency of Tall Building Through Ambient Vibration Measurement)

  • 윤성원;주영규
    • 한국강구조학회 논문집
    • /
    • 제15권2호
    • /
    • pp.117-124
    • /
    • 2003
  • 고층건물의 사용성설계는 가속도와 같은 풍응답진동에 의하여 자주 영향을 받으므로, 이때 고유진동수의 올바른 산정은 중요하다. 설계단계에서 사용되고 있는 이러한 진동수 경험식들은 상호간에 서로 다른 결과치를 제시하는 경향이 있다. 이 논문은 철골조 건물의 진동주기에 대한 것으로서, 건물의 진동실험방법과 상시진동실험에서 얻은 고유주기를 예측하기 위한 방법을 제시하였다. 서울지역 21개동의 상시진동 계측데이터에서 고유주기를 산정하였다. 철골조 고층건물의 고유주기 근사식을 제안하였으며, 고유주기의 근사식을 국내외 기준 및 고유치해석의 결과와 비교하였다.

전자처리 스페클 패턴 간섭법을 이용한 복합재료의 진동 특성 해석에 관한 연구 (A Study on the Vibration Characteristics Analysis of Composite Materials by Using Electronic Speckle PatternInterferometry Method)

  • 김형택;정현철;양승필
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.388-392
    • /
    • 1995
  • The Electronic Speckle Pattern Interferometry(ESPI) has been applied to many technical problems such as deformation and displacement measurement, strain visualization and surface roughness monitoring. Composite materials have various complicated characteristics depending on the ply materials,ply orientations,ply stacking sequences and boundary conditions. Therefore, it is difficult to analyze composite material. For efficient use of composit materials in engineering applications, the dynamic behavior such as, natural frequencies and modal patterns should be identified. This studying presents FEM results for the free vibration of symmetrically laminated composite as [30/-30/90] $_{s}$. The natural frequencies of laminated composite rectangular plates having the boundary condition(:2-edge clamped) are experimentally obtained. In order to demonstrate the validity of the experiment,FEM analysis using ANSYS was performed and natural frequencies experimentally obtained is compared with calculated by FEM analysis. The results obtained from both experiment and FEM analysis show a good agreement.t.

  • PDF

크린시설동 소음 및 진동 해석 (Research on Noise and Vibration Analysis for a clean facility)

  • 전용한;박노국;이덕수
    • 대한안전경영과학회지
    • /
    • 제19권1호
    • /
    • pp.245-255
    • /
    • 2017
  • This paper is a study to estimate the noise generated by fluid around each machine in the basement and basement facilities that accept major noise factor, pump fluid mechanical equipment installed to evaluate the impact on the real working environment. In particular, the review of the reliability of complementary information and reliability predict the natural frequency for generating a maximum strain when the vibration analysis, and intended to ensure that the design to avoid a natural frequency of the structure, on the basis of the this analysis result to the subject a real building.

Buckling and vibration behavior of a non-uniformly heated isotropic cylindrical panel

  • Bhagata, Vinod S.;Pitchaimani, Jeyaraj;Murigendrappa, S.M.
    • Structural Engineering and Mechanics
    • /
    • 제57권3호
    • /
    • pp.543-567
    • /
    • 2016
  • This study attempts to address the buckling and free vibration characteristics of an isotropic cylindrical panel subjected to non-uniform temperature rise using numerical approach. Finite element analysis has been used in the present study. The approach involves three parts, in the first part non-uniform temperature field is obtained using heat transfer analysis, in the second part, the stress field is computed under the thermal load using static condition and, the last part, the buckling and pre-stressed modal analysis are carried out to compute critical buckling temperature as well as natural frequencies and associated mode shapes. In the present study, the effect of non-uniform temperature field, heat sink temperatures and in-plane boundary constraints are considered. The relation between buckling temperature under uniform and non-uniform temperature fields has been established. Results revealed that decrease (Case (ii)) type temperature variation field influences the fundamental buckling mode shape significantly. Further, it is observed that natural frequencies under free vibration state, decreases as temperature increases. However, the reduction is significantly higher for the lowest natural frequency. It is also found that, with an increase in temperature, nodal and anti-nodal positions of free vibration mode shapes is shifting towards the location where the intensity of the heat source is high and structural stiffness is low.

핵연료 조사시험용 캡슐 구조물의 좌굴 및 진동특성 (Buckling and Vibration Characteristics of the Capsule for Nuclear Fuel Irradiation Test)

  • 강영환;김봉구;류정수;김영진;최명환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.125-130
    • /
    • 2004
  • The vibration and buckling characteristics of the capsule for fuel irradiation test are studied. The natural frequencies of the capsule in air and under water are obtained by modal testing and finite element(FE) analysis using ANSYS program, and accelerations with flow are measured to estimate the compatibility with the operation requirement of the HANARO reactor. The experimental fundamental frequency of the capsule in the x and z direction is 8.5Hz and 8.75Hz in air, and 7.5Hz and 7.75Hz under water, respectively. The maximum amplitude of accelerations under the normal operating condition is measured as 11.0m/s$^2$ that is within the allowable vibrational limit(18.99m/s$^2$) of the reactor structure. Also, the maximum displacement at 100% flow is calculated as 0.13mm which is not interference with other nearby structures. FE analysis results show that the natural frequencies are found to be similar to those of the modal testing when three supporting parts are considered as simply supported conditions. From the buckling analysis, when the loading tool is applied, the critical buckling load of the capsule is 233N.

  • PDF

핵연료 조사시험용 캡슐 구조물의 좌굴 및 진동특성 (Buckling and Vibration Characteristics of the Capsule for Nuclear Fuel Irradiation Test)

  • 강영환;김봉구;류정수;김영진;최명환
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.741-748
    • /
    • 2004
  • The vibration and buckling characteristics of the capsule for fuel irradiation test are studied. The natural frequencies of the capsule in air and under water are obtained by modal testing and finite element (FE) analysis using ANSYS program, and accelerations with flow are measured to estimate the compatibility with the operation requirement of the HANARO reactor. The experimental fundamental frequencies of the capsule in the x and z direction are 8.5 Hz and 8.75 Hz in air, and 7.5 Hz and 7.75 Hz under water, respectively. The maximum amplitude of accelerations under the normal operating condition is measured as 11.0 m/s$^2$ that is within the allowable vibrational limit(18.99 m/s$^2$) of the reactor structure. Also, the maximum displacement at 100% flow is calculated as 0.13 mm which is not interference with other nearby structures. FE analysis results show that the natural frequencies are found to be similar to those of the modal testing when three supporting parts are considered as simply supported conditions. From the buckling analysis, when the loading tool is applied, the critical buckling load of the capsule is 233 N.