• 제목/요약/키워드: Mock-up 실험

검색결과 228건 처리시간 0.048초

시멘트 종류별 수화열 및 온도응력 비교를 위한 모형타설 실험 연구 (Mock-up test for the comparison of hydration heat the thermal stress in different types of cements)

  • 김상철;이두재;강석화;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.187-192
    • /
    • 1998
  • Recent construction method in mass concrete structures would depend on the control of hydration heats and thermal stresses by using the low heat cement, optimized block size and a lift height, or both. This experimental study aims at the possibility of thermal cracks according to the different types of cementations material and at the investigation of these effects. Four different types of cements are applied to the mock-up test and are evaluated in terms of temperature rises and thermal stresses with the use of thermocouples, strain gauges and effective stress gauges. As a result of this study, it was found that stresses measured from effective stress gauges agree well with ones form strain gauges, and the trend of stress occurrence can be well evaluated from theoretical analysis.

  • PDF

한중 콘크리트용 개량형 양생막의 내풍성능에 관한 Mock-Up 실험 (Mock-Up Test on The Performance for Wind Resistance of Improved Curing Sheet in Cold Weather Concrete)

  • 최현규;백대현;손명식;이호성;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.37-38
    • /
    • 2011
  • This study is to analyze and compare improved curing sheet with blue sheet in order to verify the performance related to tensile stress. As results, it is confirmed that improved curing sheet(MP+BBS1) is better than the blue sheet at using field already. Synthetically, curing sheet improved by MP is analyzed to be available instead of the original because it is superior to tensile stress.

  • PDF

수중 침지 건조방법을 이용한 21MPa급 Mock-up부재 콘크리트의 화해피해 깊이진단 (Assesment of Impaired Depth due to Fire of Mock-up Concrete with 21MPa Using Drying Method After Water Immersion)

  • 임군수;한준희;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.241-242
    • /
    • 2021
  • In this study, we develop the damage depth diagnostic technology of fire damage concrete and propose an method of impaired depth due to fire by drying impaired concrete after immersing. Test results indicated that when assesing impared depth due to fire with the dry method after water immersing, impaired depth was clearly found and furthermore, compared with that by Phenolphthalein method 10 mm of damage depth was additionally identified, which is imposible to asses when Phenolphthalein is applied.

  • PDF

수중 침지 건조방법을 이용한 40MPa Mock-up부재의 화해피해 깊이진단 (Assesment of Impaired Depth due to Fire of Mock-up Concrete with 40MPa Using Drying Method After Water Immersion)

  • 임군수;한수환;백승복;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.245-246
    • /
    • 2021
  • In this study, we develop the damage depth diagnostic technology of fire damage concrete and propose an method of impaired depth due to fire by drying impaired concrete after immersing. Test results indicated that when assesing impared depth due to fire with the dry method after water immersing, impaired depth was clearly found and furthermore, compared with that by Phenolphthalein method 15 mm of damage depth was additionally identified, which is imposible to asses when Phenolphthalein is applied.

  • PDF

초 저수축 콘크리트의 수축특성에 관한 실험적 연구 (An Experimental Study on the Shrinkage Properties of Ultra-Low Shrinkage Concrete)

  • 서태석;김강민;이현승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.148-149
    • /
    • 2021
  • In Japan, ultra-low shrinkage concrete has been developed and commercialized to control drying shrinkage cracks to the limit. However, in the case of South Korea, the study on this technology has not yet been conducted in earnest. Therefore, the study was conducted for the development of ultra-low shrinkage concrete to control the drying shrinkage crack of concrete to the limit, and in this study, after determining the mixture of ultra-low shrinkage concrete, a wall type mock-up specimen was produced to observe the shrinkage behavior of ultra-low shrinkage concrete.

  • PDF

Mock-up 장치에서 전해정련 실험 결과

  • 우문식;강영호;황성찬;권상운;박성빈;이병직;심준보;김응호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2006년도 학술논문요약집
    • /
    • pp.117-117
    • /
    • 2006
  • PDF

주택 지붕일체형 PV시스템 후면환기에 따른 발전성능 변화 실험연구 (Experimental Study on the Combined Effect of Power and Heat according to the Ventilation of Back Side in Roof Integrated PV System)

  • 윤종호;한규복;안영섭
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.169-174
    • /
    • 2007
  • Building integrated photovoltaic(BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated. This study is to establish basic Information for designing effective BIPV by discovering relations between temperature and generation capability through experiment when the PV module is used as roof material for houses. To do so, we established 3kW full scale mock-up model with real size house and attached an PV array by cutting in half. This is to assess temperature influence depending on whether there is a ventilation on the rear side of PV module or not.