• 제목/요약/키워드: Micro-current

검색결과 1,171건 처리시간 0.025초

Design and simulation of resonance based DC current sensor

  • Santhosh Kumar, B.V.M.P.;Suresh, K.;Varun Kumar, U.;Uma, G.;Umapathy, M.
    • Interaction and multiscale mechanics
    • /
    • 제3권3호
    • /
    • pp.257-266
    • /
    • 2010
  • A novel resonance based proximity DC current sensor is proposed. The sensor consists of a piezo sensed and actuated cantilever beam with a permanent magnet mounted at its free end. When the sensor is placed in proximity to a wire carrying DC current, resonant frequency of the beam changes with change in current. This change in resonant frequency is used to determine the current through the wire. The structure is simulated in micro and meso scale using COMSOL Multi physics software and the sensor is found to be linear with good sensitivity.

미세 펄스전원을 이용한 스테인레스강 300 계열의 전기화학연마 (Study on Electrochemical Polishing for Stainless Steel 300 Series using Micro Pulse Current)

  • 이동활;박정우;문영훈
    • 소성∙가공
    • /
    • 제12권4호
    • /
    • pp.388-393
    • /
    • 2003
  • Electrolytic polishing is the anodic dissolution process in the transpassive state. It removes non-metallic inclusions and improves mechanical and corrosion resistance of stainless steel. Electrolytic polishing is normally used to remove a very thin layer of material from the surface of a metal object. An electrolyte of phosphoric acid 50% in vol., sulfuric acid 20% in vol. and distilled water 30% in vol. has been used in this study. In the low current density region, there can be found plateau region and material removal process and leveling process occur successively. In this study, an electrochemical polishing process using pulse current is adopted as a new electrochemical polishing process. In electrochemical machining processes, it has been found that pulse electrochemical processes provide an attractive alternative to the electrochemical processes using continuous current. Hence, this study will discuss the electrochemical polishing processes in low current density region and pulse electrochemical polishing.

밀리부품 성형 정밀도 향상을 위한 다단계 미세성형 해석 (Multi-stage forming analysis of milli component for improvement of forming accuracy)

  • 윤종헌;허훈;김승수;최태훈;나경환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.97-100
    • /
    • 2003
  • Globally, the various machine components, as in electronics and communications, are demanded to being high-performance and micro-scale with abrupt development of the fields of computers, mobile communications. As this current tendency, production of the parts that must have high accuracy, so called milli-structure, are accomplished by the method of top-down, differently as in the techniques of MEMS, NANO. But, in the case of milli-structure, production procedure is highly costs, difficult and demands more accurate dimension than the conservative forming, processing technique. In this paper, forming analysis of the micro-former as the milli-structure are performed and then calculate the punch force etc. This information calculated is applied to decide the forming capacity of micro-former and design the process of forming stage, dimension of dies in another forming bodies. And, for the better precise forming analysis, elasto-plastic analysis is to be performed, then the consideration about effect of elastic recovery when punch and die are unloaded, have to be discussed in change of dimensions.

  • PDF

중량 20그램의 초소형 날갯짓 비행체 개발 (Development of a Micro Ornithopter with a Weight of 20 gram)

  • 이재문;장조원;정윤식
    • 한국항공우주학회지
    • /
    • 제33권10호
    • /
    • pp.82-92
    • /
    • 2005
  • 본 연구는 중량 20그램의 무선조종 초소형 날갯짓 비행체를 개발하기 위하여 수행되었다. 본 날갯짓 비행체는 3채널 방식의 무선조종을 사용하였고, 리튬 폴리머 배터리로 두 개의 DC 페이저 모터를 구동하여 35cm 크기의 날개로 날 수 있도록 하였다. 플래핑 운동만 적용된 날갯짓 비행체의 성능은 비행시험으로 입증되었다. 비행시험 결과는 비행체의 추진에 필요한 충분한 추력이 발생하도록 개발되었다는 것을 나타낸다.

Systematic Development of Tomato BioResources in Japan

  • Ariizumi, Tohru;Aoki, Koh;Ezura, Hiroshi
    • Interdisciplinary Bio Central
    • /
    • 제3권1호
    • /
    • pp.1.1-1.6
    • /
    • 2011
  • Recently, with the progress of genome sequencing, materials and information for research on tomato (Solanum lycopersicum) have been systematically organized. Tomato genomics tools including mutant collections, genome sequence information, full-length cDNA and metabolomic datasets have become available to the research community. In Japan, the National BioResource Project Tomato (NBRP Tomato) was launched in 2007, with aims to collect, propagate, maintain and distribute tomato bioresources to promote functional genomics studies in tomato. To this end, the dwarf variety Micro-Tom was chosen as a core genetic background, due to its many advantages as a model organism. In this project, a total of 12,000 mutagenized lines, consisting of 6000 EMS-mutagenized and 6000 gamma-ray irradiated M2 seeds, were produced, and the M3 offspring seeds derived from 2236 EMS-mutagenized M2 lines and 2700 gamma-ray irradiated M2 lines have been produced. Micro-Tom mutagenized lines in the M3 generation and monogenic Micro-Tom mutants are provided from NBRP tomato. Moreover, tomato cultivated varieties and its wild relatives, both of these are widely used for experimental study, are available. In addition to these bioresources, NBRP Tomato also provides 13,227 clones of full-length cDNA which represent individual transcripts non-redundantly. In this paper, we report the current status of NBRP Tomato and its future prospects.

SUS 304 마이크로 와이어 직선화 처리에 관한 연구 (Study on Micro Wire Straightening Process in SUS 304)

  • 신홍규;김남수;김웅겸;홍남표;김병희;김헌영
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.17-22
    • /
    • 2004
  • In the study, we have developed a straightening system for 304 micro wires that are normally used in the medical and semi-conductor fields. To apply heat to the micro wires, we introduced the direct wire heating method which generates the thermal energy by the electrical resistance of the wire itself. To avoid the deterioration of the wire surface by the environment, such as the oxidation or the hydration, the $N_2$ gas was filled in the glass pipe in which the straightening process was being performed. A precision tension meter was also attached to control the tension of the wire during the heating and straightening process. In order to control the straightening process, several experimental investigations with varying the tension, the feeding velocity and the temperature (current) was carried out. As a result of experiments, we obtained the optimal processing conditions satisfying the straightness requirement of the micro wires.

  • PDF

MicroRNAs: Biogenesis, Roles for Carcinogenesis and as Potential Biomarkers for Cancer Diagnosis and Prognosis

  • Kavitha, Nowroji;Vijayarathna, Soundararajan;Jothy, Subramanion Lachumy;Oon, Chern Ein;Chen, Yeng;Kanwar, Jagat Rakesh;Sasidharan, Sreenivasan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7489-7497
    • /
    • 2014
  • MicroRNAs (miRNAs) are short non-coding RNAs of 20-24 nucleotides that play important roles in carcinogenesis. Accordingly, miRNAs control numerous cancer-relevant biological events such as cell proliferation, cell cycle control, metabolism and apoptosis. In this review, we summarize the current knowledge and concepts concerning the biogenesis of miRNAs, miRNA roles in cancer and their potential as biomarkers for cancer diagnosis and prognosis including the regulation of key cancer-related pathways, such as cell cycle control and miRNA dysregulation. Moreover, microRNA molecules are already receiving the attention of world researchers as therapeutic targets and agents. Therefore, in-depth knowledge of microRNAs has the potential not only to identify their roles in cancer, but also to exploit them as potential biomarkers for cancer diagnosis and identify therapeutic targets for new drug discovery.

3D프린팅 활용 생체의료분야 기술동향 (Current Status of Biomedical Applications using 3D Printing Technology)

  • 박석희;박진호;이혜진;이낙규
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1067-1076
    • /
    • 2014
  • To date, biomedical application of three-dimensional (3D) printing technology remains one of the most important research topics and business targets. A wide range of approaches have been attempted using various 3D printing systems with general materials and specific biomaterials. In this review, we provide a brief overview of the biomedical applications using 3D printing techniques, such as surgical tool, medical device, prosthesis, and tissue engineering scaffold. Compared to the other applications of 3D printed products, the scaffold fabrication should be performed with careful selection of bio-functional materials. In particular, we describe how the biomaterials can be processed into 3D printed scaffold and applied to tissue engineering area.

전기화학적 식각정지에 의한 고수율 실리콘 박막 멤브레인 제작 (Fabrication of High-yield Si Thin-membranes by Electrochemical Etch-stop)

  • 정귀상;박진상;이원재;송재성
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.223-227
    • /
    • 2001
  • In this paper, the authors present the fabrication of high-yield Si thin-membranes by electrochemical etch-stop in tetramethyl ammonium hydroxide (TMAH): isopropyl alcohol (IPA):pyrazine solutions. The current-voltage (I-V) characteristics of n- and p-type Si in TMAH:IPA;pyrazine solutions were analysed, repsectively. Open circuit potential (OCP)and passivation potential (PP) of n- and p-type Si, respectively, were obtained and applied potential was selected between n- and p-type Si PPs. The electrochemical etch-stop method was applied to the fabrication of 801 micro-membranes with 20.0 $\mu\textrm{m}$ thickness on a 5" Si wafer. The average thickness of fabricated 801 micro-membranes on one wafer 20.03$\mu\textrm{m}$ and the standard deviation was ${\pm}$0.26$\mu\textrm{m}$. The Si surface of the etch-stopped micro-membranes was extremely flat with no noticeable taper or nonuniformity. The results indicate that use of the electrochemical etch-stop method for the etching of Si in TMAH:IPA;pyrazine solutions provides a powerful and versatile alternative process for fabricating high-yield Si micro-membranes.

  • PDF

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • 제1권2호
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.