• Title/Summary/Keyword: Meter set

Search Result 199, Processing Time 0.025 seconds

Analysis of Citizen's Attitude to the Foodwaste (II) (음식쓰레기에 관한 실태조사(II))

  • Jang, Won;Kim, Mikyeong;Kang, Changmin;Park, Youngsuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.5 no.1
    • /
    • pp.53-61
    • /
    • 1997
  • This study was conducted to analysis citizen's attitude and style to the foodwaste from l0th Sept. to 30th Sept. in 1996. The research was used questionare method and analysis was used prequency analysis and cross table method by SPSS (scientific statistics). The foodwaste of householdwaste account for 24.8%, and the magnitude by the kinds of garbage were waste from pre-cocking stage, fruitshell, foodwaste remained after eating, septic foodwaste during storage. The more the housewives'age are young, foodwaste volumne were much. Most remained foodwaste after eating were soup and pot stew. The main cause of foodwaste production was overvolumne cooking. 88.8% of answers think that a menu can be useful to reduce foodwaste. The survey showed that 87.3% of answers put into the meter-rate bag after removed wetness of garbage. 84.1% of answers thought that the recycling of foodwaste needed, but the practical housewife was only 21%. For the suitable treatment of foodwaste, Survey showed that the consistent policy of goverment and continuous publicity was needed essentially, and that the public notice of TV or radio was effective. All of answers would like to participate in recycling of foodwastes whether public-posting or personal-posting. To set up vessel of posting at household, the proper purchase price and space of institution are needed, also the solution of sanitory & aesthetic problem and the collection of composting-product must be achieved smoothly.

  • PDF

Change of PAE according to Detector Measurement Method (검출기 측정방법에 따른 PAE값의 변화)

  • Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • The aim of this study is to investigate PAE, as the result of the test of kVp accuracy, according to detector measurement method. Based on the indicated value of 70kVp, each distance between a focus and a kVp meter was 100cm, 80cm and 60cm and the angle of X-ray tube was set on $5^{\circ},\;10^{\circ},\;15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ}$. Each indicated value, 60kVp, 70kVp, 80kVp, 90kVp and 100 kVp, was used compare Small focus with Large focus. As a result, PAE on the side of cathode was higher than it on the side of anode in the case of 100cm and PAE on the side of anode was higher in the case of 80cm and 60cm. The coefficient rate was stable both the side of cathode and anode in the case of 100cm and it was fluctuated in the case of 80cm and 60cm. PAE in the case of Small focus was higher than Large focus and it was disproportionate to an indicated value. Error rate was in inverse proportion to the indicated value.

Analysis of Urban Inundation Considering Building Footprints Based on Dual-Drainage Scheme (건물의 영향을 고려한 이중배수체계기반 침수해석)

  • Lee, Jeong-Young;Jin, Gi-Ho;Ha, Sung-Ryong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.40-51
    • /
    • 2014
  • This study aims to investigate urban inundation considering building footprints based on dual-drainage scheme. For this purpose, LiDAR data is cultivated to generate two original data set in terms of DEM with $1{\times}1$ meter and building layer of the study drainage area in Seoul and then the building layer is overlapped as vector polygon with the mesh data with the same size as DEM. Then, terrain data for modeling were re-sampled to reduce resolution as $10{\times}10$ meters. As results, the simulated depth without considering building footprints has a tendency to underestimate the inundation depth compared to observed data analized by CCTV imagery. Otherwise, the simulation result considering building footprints revealed definitely higher fitness. The difference of inundation depth came from the variation of inundation volume which was relevant to inundation extent. If the building footprints are enlarged, the possible inundation depth is increased, which results in being inundation depth higher because hydrological conditions such as rainfall depth are conservational. Otherwise, according to comparison of inundation extents, there were no significant difference but the case of considering building footprint was revealed slightly higher fitness. Thus, it is concluded that the considering building footprint for inundation analysis of urban watershed should be required to improve simulation accuracy synthetically.

Sensitivity Experiments of Vertical Resolution and Planetary Boundary Layer Parameterization Schemes on the Seoul Metropolitan Area using WRF Model (수도권 지역의 고해상도 WRF 모델 기반 연직 해상도 및 경계층 모수화 방안 민감도 실험)

  • Lim, A-Young;Roh, Joon-Woo;Jee, Joon-Bum;Choi, Young-Jean
    • Journal of the Korean earth science society
    • /
    • v.36 no.6
    • /
    • pp.553-566
    • /
    • 2015
  • The effects of vertical resolutions and planetary boundary layer (PBL) physics schemes in a numerical simulation with a very high resolution over the metropolitan area were investigated. The numerical experiments using the Weather Research and Forecast model were conducted from 0000 UTC 25 October to 0000 UTC 26 October 2013. We verified the numerical results against with six hourly observation data from the radiosonde at Seolleung, which was located in southern part of Seoul, and forty three auto weather systems in Seoul. In the experiments of vertical resolutions in low level atmosphere with 44, 50, and 60 layers, which are set to be subdivided particularly under 2 km height. The experiment in 60 layers, which has the highest vertical resolution in this study, showed relatively a clear diurnal variation of PBL heights. Especially, the difference of PBL heights and 10-meter wind fields were mainly seen in the area of high altitude lands for the experiments of vertical resolution. In the sensitivity experiment of PBL schemes such as asymmetric convective model-version 2 (ACM2), Yonsei University (YSU), and Mellow-Yamada-Janjic (MYJ) to the temperature, all three PBL schemes revealed lower temperature than observed profile from the radiosonde in the entire period. The experiments with YSU PBL and ACM2 PBL schemes show relatively less biased in comparison with the experiment of the MYJ PBL scheme.

Integrated Network System of Milk Cow Stock-Farming Facilities for Stockbreeding Management (사양관리를 위한 젖소 목장 시설 통합 네트웍 시스템)

  • 김지홍;이수영;김용준;한병성;김동원
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.199-208
    • /
    • 2002
  • This paper introduces the method to make management network about milking cow farm tasks. The object of this research was to design of biological measuring system and managing network system in a livestock farm. This auto-management system provides informations about individual cows' temperature, conductivity of milk and weight for efficient management of feeding, and milking works by a micro-processor and RS -485 type serial COM. ports. And measured bio-data which are basic informations for remote raising management are saved to user PC by serial communication between the PLC and user PC. Milking cow farm is divided into three working place to each measurement work and feed. The first working place is milking station which has two thermometers, a conduct meter and a scale set. The second working place is feeding station, and the third place is cattle cage. These are combined by network system and the PLC which is used to drive network and sub-modules. Sub-modules have a micro-process to control the sensor and to interface with network. The PLC which drive network and control sequence has two serial communication port to be linked with user PC for sending the measured data and for receiving data. Above all, in this study tells the sequence operating method by the driving scenario of breeding milk cow for livestock auto-management using the PLC and network system.

  • PDF

The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites (산업장 소음의 강도 및 주파수 특성에 관한 조사연구)

  • Kim, Kwang Jong;Cha, Chul Whan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF

Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography (치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가)

  • Jeong, Cheonsoo;Kim, Jiyoung
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.433-438
    • /
    • 2015
  • To evaluate the radiation exposure level based on radiation workers' locations in dental radiography, the radiation dose rate in the radiographic room, lead glass, and operation system was measured. To that end, various devices were used, such as a Standard(Max-GLS, Shinhung), a panorama (PCH-2500, Vatech), a cephalometric radiography (PCH-2500), and a cone beam CT (PHT-30LFO, Vatech), as well as a PM1405 equipment as a radiation meter. Radiography conditions were set the same as the factors used in the clinical setting. As the result, the cone beam CT turned out the highest with 98 uSv and the standard showed the lowest level with 0.4 uSv/h. The panorama was measured to be higher than the Cephalo due to its different focus mode. On the lead glass surface and in the operation stand, the oral radiography device, panoramic, and Cephalo all were measured below the recording level. However, the cone beam CT was measured to have the leakage dose. Thus, radiation involved workers should be equipped with appropriate protection tools and reduce radiography time as much as possible. In addition, the structure of the radiation chamber should be also designed efficiently. Dental radiography has continued to grow in recent years, so it is necessary take appropriate protection measures for patients and radiation workers.

Corrosion Loss of the Shell Plates of the General Cargo Vessels and the Lumber Carriers According to the Age (일반화물선과 원목운반선의 선각외판 부식도의 선령별 변화)

  • 박중희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 1981
  • Corrosion loss of the shell plates of the steel vessels are measured and analyzed on the thirty cargo vessels and fifteen lumber carriers of which nationality belong to Korea. Thickness of the shell plates were determined at the every observed points set along the fore and aft line and perpendicular to it, by use of the ultrasonic thickness meter. Difference of the thickness between the original and the determined shell plates are given as the corrosion loss at the present age. The results obtained are summarized as follows: 1. On the cargo vessels, (1) The total mean of the corrosion loss is greatest at the light waterline, in every age class of the vessels. (2) The total mean of the corrosion loss on the fore and aft line shows little difference, even though it is slightly greater at the fore part, in every age class of the vessels. (3) Corrosion loss along the perpendicular line grows greater in the order of freeboard, load waterline, upper bilge line and light waterline, within the 16 of the age of the observed vessels. Its order varies to freeboard, upper bilge line, load waterline and light waterline in the age of 35. Corrosion loss at the light waterline and load waterline, in the age of 35, shows 3 times of it at the freeboard, and it at the upper bildge line shows twice of it at the freeboard. The fact significates the corrosion grows rapidly around the waterline. 2. On the lumber carriers, (1) The total mean of the corrosion loss is greatest at the upper bilge line, in the every age class of the vessels. (2) Total mean of the corrosion loss on the fore and aft line shows little difference, even though it is slightly greater at the fore part, in every age class of the vessels. (3) Corrosion loss along the perpendicular line is least at the freeboard and greatest at the upper bilge line, and its value at the upper bilge line shows twice of it at the freeboard. 3. The total mean of the corrosion loss of the lumber carriers shows almost twice of the cargo vessels.

  • PDF

A Study on the Safety of a Screening X-ray Laboratory Using Containers in accordance with the COVID 19 Outbreak (COVID 19 유행에 따른 컨테이너를 이용한 선별 X-선 검사실의 안전성에 대한 고찰)

  • Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.425-431
    • /
    • 2020
  • When a radiation generating device is installed in an export container due to COVID-19, the purpose of this study was to measure the space dose in the radiation room and to study the effectiveness of the shielding wall in the laboratory. Air dose measurement method was set behind the X-ray tube, 50 cm, 100 cm, 200 cm, and measured 12 locations. The dose values before and after the use of the movable radiation shielding wall were compared by measuring 3 locations behind the X-ray tube using the movable radiation shielding wall. The measured values were 50 cm on the left behind the X-ray tube: 1.446 μSv, behind the X-ray tube: 0.545 μSv, and 50 cm on the right behind the X-ray tube: 1.466 μSv. Measurements behind the radiation barrier were 0.190 μSv, 0.204 μSv, and 0.191 μSv. As a result of performing the corresponding sample t test of the average value according to the use of movable barrier walls, p <0.001 was found. As a result of the actual measurement, the medical exposure of the examiner due to the shielding wall in the laboratory decreased to 82.3%. In order to reduce occupational exposure in screening radiological laboratories, it is recommended that sufficient separation from radiation sources and the use of shielding walls are recommended.

Study on the Improvement of Land Clearing Methods by Bulldozer & Fertilization of Cleared Soil (불도우저에 의한 개간 공법의 개선과 숙지화에 관한 연구)

  • Hwang, Eun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3627-3641
    • /
    • 1975
  • The Government is trying to increase total food grain yield to meet national self sufficiency by means of increasing unit yield as well as extending crop land, and this year he set the target of 321,000 hectare of forest to clear for cropping. This study was carried to investigate the most efficient method of clearing hillock by bulldozer, and successful method to develope yielding potential of newly cleared land in short term. Since the conventional land clearing method is just earth leveling and root removing neglecting top soil treatment, the growth of crop was poor and farmer tends not to care the land. The top-soil-furrowing method is applied through out this study, that is advantageous especially for the land having shallow top soil and low fertility like Korean forest. In this study, various operating method were tried to find out most efficient method separately in connection with the land slope less than 25 percent and over, and several fertilizing methods to develop yielding potential. The results are as follows; 1) For the natural land slope utilization method, applicable to the land having less than 25 percent slope, reverse operating was more efficient than using forward gear of bulldozer. The operating time was 3 hour 32 minutes and 36 seconds using forward gear was 2 hour 32 minutes and 30 seconds for reverse gear operation per 1,000 square meter. 2) Bulldozer having angle blade adjustment needed 7hr 15min. for constructing of terrace per 10a compaire with the one having angle & tilt adjustment needed 6hr 4min for same operations. Specially there is significant difference for operation time of first period (earth cutting) such as bulldozer having angle blade adjustment needed 3hr 56min compaired with the one having angle & tilt adjustment 3hr 59min. In construction of terrace, the bull-dozer having tilting and angle blade adjustment was most suitable and performed efficiently. 3) For the fertilizer application treatment, the grass (Ladino clover) yield in first year was almost same as ordinary field's in the plot applied(N.P.K+lime+manure) while none fertilizer plot showed one tenth of it, and (N.P.K.+lime) applied plot yielded on third. 4) The effect of different land clearing method to yield showed significant difference between each treatment especially in the first year, and the conventional method was the lowest. In the second year, still conventional terracing plot yielded only half of ordinary field while the other plots showed as same as ordinary field's. 5) The downward top soil treatment plot showed most rapid improvement in soil structure during one year physio chemically, it showed increase in pH rate and organic composition, and the soil changed gradually from loam to sand-loam and the moisture content increased against the pF rate, and it gives good condition to grow hay due to the increase of field water capacity with higher available water content. 6) Since the soil of tested area was granite, the rate of soil errosion was increased about 2 to 5 percent influencing in soil structure more sand reducing clay content, and an optimum contour farming method should be prepared as a counter measure of errosion.

  • PDF