• Title/Summary/Keyword: Maxillofacial

Search Result 6,642, Processing Time 0.035 seconds

Facial soft tissue measuring analysis of normal occlusion using three-dimensional CT imaging (3차원 CT 영상을 이용한 정상교합자의 안면 연조직 계측 분석)

  • Han, Soo-Yeon;Baik, Hyoung-Seon;Kim, Kee-Deog;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.409-419
    • /
    • 2005
  • Studies for diagnostic analysis using three-dimensional (3D) CT images are recently in progress and needs for 3D craniofacial analysis are increasing in the fields of orthodontics. It is especially essential to analyze the facial soft tissue after orthodontic treatment and orthognathic surgery. In this study 3D CT images of adults with normal occlusion were taken to analyze the facial soft tissue. Norms were obtained from CT images of adults with normal occlusion (12 males, 11 females) using a computer program named V works 4.0 program. 3D coordinate planes were established using soft tissue Nasion as the reference point and a total of 20 reproducible landmarks of facial soft tissue were obtained using the multiple reconstructive sectional images (axial, sagittal and coronal images) of the V works 4.0 program: soft tissue Nasion, Pronasale, Subnasale, Upper lip center, Lower lip center, soft tissue B, soft tissue Pogonion, soft tissue Menton, Endocanthion (Rt/Lt), Alare lateralis (Rt/Lt), Cheilion (Rt/Lt), soft tissue Gonion (Rt/Lt), Tragus (Rt/Lt), and Zygomatic point (Rt/Lt). According to the established landmarks and measuring method, the 3D CT images of adults with normal occlusion were measured and the normal positional measurements and their Net (${\delta}=\sqrt{{X^2}+{Y^2}+{Z^2}}$) values were obtained using V surgery program, In the linear measurement between landmarks, there was a significant difference between males and females except Na' -Sn and En(Rt)-En(Lt). The normal ranges of Na'-Zy, Na'-Ch and Na'-Go' (facial depth) were obtained, which was difficult to measure by two-dimensional (2D) cephalometric analysis and facial photographs. These data may be used as references for 3D diagnosis and treatment planning for patients with malocclusion and dentofacial deformity.

Analysis of Patients with Mandibular Nerve Damage after Root Canal Therapy (근관치료 후 발생한 하악신경 손상 환자에 대한 분석)

  • Lee, Ji-Soo;Song, Ji-Hee;Kim, Young-Gun;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.327-336
    • /
    • 2011
  • Reported causes of mandibular nerve injury in relation to neuropathic pain in dentistry include extraction, dental implant surgery, oral and maxillofacial surgery, periodontal treatment, and root-canal therapy. This study analyzed the characteristics of pharmacologic management of neuropathy after root-canal therapy. 32 patients who complain of abnormal sensation or pain after root-canal therapy and were referred to Department of Oral Medicine and the Temporomandibular Joint and Orofacial Pain Clinic at the Dental Hospital of Yonsei University, Seoul, Korea from 2004 to 2011 enrolled in this analysis and improvement of symptom was evaluated after pharmacologic management. Thirty-two patients who had hypoesthesia or dysesthesia at the initial visit were analyzed(9 men, 23 women; mean age: 44 years). The causes of neuropathy were local anesthesia(46.9%), chemical trauma from the sealant in root-canal(25%), endodontic surgery(15.6%), and unknown causes(12.5%). Medications such as steroids, anticonvulsants, antidepressants, and analgesics were took for improvement of symptoms and titrated for a variety of period from 1 week to 11 months. It was found that neuropathy of the inferior alveolar nerve and the lingual nerve was in 25 and 7 patients. The improvement of neurosensory disturbance and no improvement after pharmacotherapy was in 21(66%) and 11(34%) patients respectively. The hypoesthesia and dysesthesia was improved 67% and 65% respectively. These results suggest that symptomatic improvement by pharmacologic management can be possible in patients with neuropathy after root-canal therapy. But improvement of symptoms was influenced by the causes and degree of nerve injury, the periods of pharmacotherapy, and the choice of treatment methods. So, further investigation is needed by quantitative measurement of more variables in more individuals.

Clinical Comparison of Immediately Loaded and Delayed Loaded OSSTEM GS III Implant in Partially Edentulous Patients (자연치 부분 결손 환자에서 테이퍼 형태의 국산 임플란트(OSSTEM GS III)의 즉시하중 성공률에 대한 지연하중군과의 비교 임상연구)

  • Kwon, Min-Jung;Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.267-275
    • /
    • 2011
  • This prospective study was designed to compare clinical outcomes of immediately loaded implant with delayed loaded implant in partially posterior edentulous patients. For test group, 42 GS III (Osstem, Korea) implants in 17 patients were loaded within 48 hours after the placement. Control group was 27 implants in 15 patients loaded at $2.6{\pm}1.7months$ from the placement surgery. Before loading, primary stability was evaluated by ISQ value. Clinical symptoms, mobility, soft tissue state was evaluated at baseline, 3 months, 6 months and 12 months of loading. Marginal bone level change was also measured with periapical radiographs. Mann-Whitney test (${\alpha}$=0.05) and repeated measured ANOVA (${\alpha}$=0.05) was used for marginal bone level change between two groups. At the baseline, mean ISQ value of test group and control group was $80.3{\pm}7.1$ and $69{\pm}17$ respectively. Test group showed 95.23% of success rate and 100% of control group was successful. At 3 and 6months of loading, significantly more bone resorption was observed in test group than in control group (p<0.05). However, there was no significant difference in the bone level change at 12months of loading between two groups (p>0.05). Marginal bone level change showed no significant difference with gender and location (p>0.05). Within the limitation of this study, when primary stability was obtained, immediate loading of GS III implant at posterior region could be predictable treatment option.

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

Clinical outcomes of implant supported fixed-hybrid prostheses in the fully edentulous arches (완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kwon, Min-Jung;Kim, Young-Kyun;Cha, Min-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.183-189
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate clinical outcomes of implant supported fixed-hybrid prostheses (FHP) in the fully edentulous arches. Materials and methods: Patients in this retrospective study were restored with fixed-hybrid prostheses supported by 4 to 6 implants and functioned more than 1 year of loading. Outcome measures were marginal bone change of implant related with sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients, tilting of posterior implant by Mann- Whitney U test and cantilever length of superstructure by regression analysis, and complication rates. Significance level was set P<.05. Results: A total number of 84 implants (16 restorations) placed in 16 patients were observed for 28 months and mean marginal bone loss was $0.53{\pm}0.39mm$. There were no differences of marginal bone loss according to sex, anatomical location (maxilla vs. mandible), opposing teeth, loading time of patients (P>.05), and cantilever length was not significantly related with a marginal bone loss of implant next to cantilever (P>.05). Complication was shown in 11 patients and veneer fracture and dislodging of artificial teeth were most prevalent. Conclusion: Within the limitations of this study, although marginal bone loss of FHP was very little, complication rates were high. Irrespective of tilting of most posterior implants, marginal bone loss of most posterior implants next to cantilever was less than those of the other implants positioned anteriorly. Cantilever length (<17 mm) did not affect a marginal bone loss of most posterior implants.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

The efficacy evaluation of $PostPlant^{TM}$ Calcium in dental implant placement (임플란트 식립 환자의 $PostPlant^{TM}$ Calcium 투여 효과에 대한 임상연구)

  • Choi, Yu-Sung;Kim, Eun-Kyung;Kim, Se-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the changes in bone density and reduction of time consumed for osteogenesis by $PostPlant^{TM}$ Calcium and to find out efficacy of $PostPlant^{TM}$ Calcium by comparing the group prescribed with $PostPlant^{TM}$ Calcium with the group without $PostPlant^{TM}$ Calcium prescription. Material and methods: The experimental group of 18 patients with 25 dental implant placement and the control group of 7 patients with 9 dental implant placement were randomly selected from the patients who visited prosthetic department of Dankook University Dental Hospital since July, 2006 (IRB Number ; 20060710). The experimental group was instructed to take $PostPlant^{TM}$ Calcium for 6 months after the implant surgery while the control group was instructed not to. Both experimental and control group were assigned for measurement using $Osstell^{TM}$ Mentor and $Periotest^{(R)}$ and radiographic examination was performed using specifically manufactured Aluminum Step Wedge. The results were compared and analyzed. Results: 1. According to the $Osstell^{TM}$ Mentor measurement, both the experimental and control group showed increase in values as time elapses and the experimental group showed significantly higher rate of increase (P < .05). 2. According to the $Periotest^{(R)}$ measurement, both the experimental and control group showed decrease in values as time elapses. In addition, greater decrease can be seen in the experimental group but no statistical significance was found. 3. By examining the radiographic images, both the experimental and control group showed tendency of increase in bone density. In addition, greater increase can be seen in the experimental group but no statistical significance was found. Conclusion: Clinically, taking $PostPlant^{TM}$ Calcium medicine for a long period of time after implant placement is expected for a better prognosis.

Three-dimensional finite element analysis of stress distribution for different implant thread slope and implant angulation (임플란트 나사선 경사각과 식립 각도에 따른 3차원 유한요소 응력분석)

  • Seo, Young-Hun;Lim, Hyun-Pil;Yun, Kwi-Dug;Yoon, Suk-Ja;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: The purpose of this study was to find an inclination slope of the screw thread that is favorable in distributing the stresses to alveolar bone by using three dimensional finite element analysis. Materials and methods: Three types modelling changed implant thread with fixed pitch of 0.8 mm is the single thread implant with $3.8^{\circ}$ inclination, double thread implant with $7.7^{\circ}$ inclination and the triple thread implant with $11.5^{\circ}$ inclination. And three types implant angulation is the $0^{\circ}$, $10^{\circ}$ and $15^{\circ}$ on alveolar bone. The 9 modelling fabricated for three dimensional finite element analysis that restored prosthesis crown. The crown center applied on 200 N vertical load and $15^{\circ}$ tilting load. Results: 1. The more tilting of implant angulation, the more Von-Mises stress and Max principal stress is increasing. 2. Von-Mises stress and Max principal stress is increasing when applied $15^{\circ}$ tilting load than vertical load on the bone. 3. When the number of thread increased, the amount of Von-Mises stress, Max principal stress was reduced since the generated stress was effectively distributed. 4. Since the maximum principal stress affects on the alveolar bone can influence deeply on the longevity of the implants. When comparing the magnitude of the maximum principal stress, the triple thread implant had a least amount of stress. This shows that the triple thread implant gave a best result. Conclusion: A triple thread implant to increase in the thread slope inclination and number of thread is more effective on the distribution of stress than the single and double thread implants especially, implant angulation is more tilting than $10^{\circ}$ on alveolar bone. Thus, effective combination of thread number and thread slope inclination can help prolonging the longevity of implant.

EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS (수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가)

  • Lee, Eun-Hye;Choi, Hang-Moon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.188-197
    • /
    • 2010
  • The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts. Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany) The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of $10{\times}10$ pixel and compared in mm Al equivalent at five points. Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken. We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area. The following results were obtained. 1. Each post system showed various radiopacity. 2. There was change of discriminability between each post and simulated specimens regardless of examiner. Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.

Pulp Response of Mineral Trioxide Aggregate, Calcium Sulfate or Calcium Hydroxide (Mineral trioxide aggregate, calcium sulfate와 calcium hydroxide의 치수에 대한 반응)

  • Yun, Young-ran;Yang, In-Seok;Hwang, Yun-Chan;Hwang, In-Nam;Choi, Hong-Ran;Yoon, Suk-Ja;Kim, Sun-Hun;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • This study was performed to verify the possibility of MTA and calcium sulfate as a pulp capping agent through comparing the dental pulp response in dogs after capping with MTA, calcium sulfate, and calcium hydroxide. 24 teeth of 2 dogs, 8 month old, were used in this study. Under general anesthesia, cervical cavities were prepared and pulp was exposed with sterilized #2 round bur in a high speed handpiece. MTA calcium hydroxide, and calcium sulfate were applied on the exposed pulp. Then the coronal openin,fs were sealed with IRM and light-cured composite. Two months after treatment, the animals were sacrificed. The extracted teeth were fixed in 10% neutral-buffered formalin solution and were decalcified in formic acid-sodium citrate. They were prepared for histological examination in the usual manner. The sections were stained with haematoxylin and eosin. In MTA group, a hard tissue bridges formation and newly formed odontoblasts layer was observed. There was no sign of pulp inflammatory reaction in pulp tissue. In calcium hydroxide group, there was no odontoblast layer below the dentin bridge. In pulpal tissue, chronic inflammatory reaction with variable intensity and extension occurred in all samples. In calcium sulfate group, newly formed odontoblast layer was observed below the bridge. Mild chronic inflammation with a few neutrophil infiltrations was observed on pulp tissue. These results suggest that MTA is more biocompatible on pulp tissue than calcium hydroxide or calcium sulfate.