• Title/Summary/Keyword: Materials data

Search Result 10,948, Processing Time 0.047 seconds

Measuring Attitudes and Satisfaction Level towards Military Foodservices (군 급식소의 이용실태 및 만족도 조사)

  • Kang, Bo-Kyoung;Lee, Young-Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.7
    • /
    • pp.1032-1042
    • /
    • 2011
  • The purpose of this study was to examine the attitudes and satisfaction level towards military foodservices as well as suggest effective ways to increase foodservice quality. A questionnaire survey was administered to 413 subjects, which included 400 soldiers and 13 foodservice managers. The survey period was from August 6 to August 25, 2008. The collected data were statistically treated using SPSS V12.0. Most of the investigated soldiers were 20~25 years old. The foodservice managers were male general officials and the majority of them had no prior food service training. None of the foodservice managers had a dietician certificate. Menu was planned through a local foodservice conference, and most food materials were delivered in the form of center-type and military unit-type. Deficiency and deterioration of food service facilities (28.6%) as well as deficiency in the number of cooking personnel (14.3%) increased the difficulty of operational management. Soldiers expressed a desire for increases in Western (25.7%) and Korean traditional foods (21.5%), which meant menu diversity. To increase the quality of military foodservices, taste of food (40.6%), increased portion size (30.4%), and improvement in hygienic conditions (13.6%) were demanded by the soldiers. Food taste (30.8%), improvement in hygienic conditions (23.1%), and better job management were all demanded by the foodservice managers. After factor analysis, quality attributes were rearranged into five dimensions, including facilities, food, menu, service, and sanitation most attributes were over 4 points out of 5 total in importance, but only 3 points in performance. The importance score was higher than the performance score. Soldiers' overall satisfaction level was on average 3.43 points out of 5 points.

A Study on Family Planning Rumors & Practice in Rural Communities (일 농촌지역 가족계획 풍문과 실천에 관한 연구)

  • 추수경
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.2
    • /
    • pp.63-77
    • /
    • 1978
  • Studies pertaining to influential factors on adoption and practice of family planning are very much needed to lower fertility, for family planning has regarded as only one social acceptable means to curb the accelerated population growth. One of the influential factors is known as rumors on family planning methods that hinder the actual practice of family planning. This study generally aimed at disclosing rumors on family planning methods prevalent in rural communities so that one could gain some in sights to cope with the ill effects of rumors to promote family planning Practice in rural communities in Korea. In order to accomplish the general aims this study formulated following four specific objectives; 1. Find out types and frequencies of rumors exposed of contraceptive methods. 2. Find out the relationship between the rumors exposed and socio-economic and demographic characteristics of new village leaders and health workers. 3. Examine the relationship between family planing rumors and family planning practices. The materials for this study were drawn from the two different sets of data gathered in July and Octorber 1977 respectivily by Center for Population & family Planning, Yon sei University. One is current family planning practice among eligible women reaiding in 4 Myuns in Kwang Wha country and the other is Survey on Rumor on family planning method heard by new village leaders and health workers in the four myuns. The four Myuns were divided into 60 small areas. Current family planning practice rate in each small area and as a whole were calculated. The unit of analysis in this study was not the indviduel person but the 55 small areas. Percentage, average, F-Test t-test and a coefficient of correlation were used for statistical analysis. Results of this study could be summarized as follows: 1. Rumors by different method of contraception: Medical complications, gastro-intestinal disorders, and difficulty in usage one most prevalent rumors about oral pills. Around 49% -77% of the 55 areas were often heard and the most frequent rumor was related medical complications of oral pills. Rumors on medical complications and incomplete effect of intrauterines as contraceptive were heard 51-66% of the 55 small areas. Rumors that vasectomy resulted in family problems, for instance infiedelity of spouse were often heard to 44% of the 55 small areas. 2. Rumors by socio-economic and demographic characteristic of new village leader and health workers: Among the demographic characteristics such as sex, age and sex composition of children, sex and age differentials in frequency of rumors heard more observed, Female new village health workers have heard more frequently than male new village leader. (t = 7.137, p> 0.01, d.f. = 53, a coefficient of correlation 0.27, p>0.05) The Younger age group less than 40 years of age have heard rumors of than the group over 40 years old. (t = 7.18, p>0.01, d.f. = 53, a coefficient of correlation 0.27, p>0.05) However, it was not observable that a consistent sex and age differentials in frequency of rumors heard of each contraceptive mettled, But, more female new village health works heard of rumors about intrauterine device than male new village leaders. (t = 0.497, p> 0.01, d.f. = 53, a coefficient of correlatin 0.32, p>0.01) 3. It was found that there was no statistically significant relationship between the frequency of rumors heard and current family planning practices on the whole, However, frequency of rumors heard about vasectomy appeared to have a positive relationship with current practice of vasectomy. A rather consistent pattern of relationship between“requency of rumors heard”and current family practice rate was demonstrated of 10 graphes which showed the relation between the two variagles. The current family planning practice rate in the“never heard”group and “frequently heard”group was equally lower than that in“often heard”group. The relatively consistent ∩ pattern of relationship needs to be farther investigated, for this pattern is different from the relationship that has been assumed to exist between these two variables.

  • PDF

An Analysis of the High School 'Common Science' Contents and Textbooks (고등학교 ‘공통과학’의 교과내용 및 교과서 분석)

  • Lee, Gwang-Ho;Choi, Jong-Bum;Park, Moon-Kook;Cho, Kyu-Seong
    • Journal of the Korean earth science society
    • /
    • v.18 no.6
    • /
    • pp.453-463
    • /
    • 1997
  • The contents of high school 'Common science' textbooks was analyzed qualitatively and quantitatively. Seven common science textbooks were selected and its contents, structure, inquiry, activities, appendix and its characteristics were investigated, and analyzed using the Goal Clusters of Project Synthesis and Romey's indices of text evaluation were calculated. The contents of each unit are not much different among textbooks because they are written according to the curriculum ordinance and textbook guidelines of the Ministry of Education. The textbooks was consist of $471{\sim}519$ pages. It was distribute similarly among the chapter of 'materials', 'forces', lives' and 'earth'. The chapter of 'energy' and 'environment' was treat significantly. The contents and structure of common science is a mere physical consolidation. I make an alternative plan that a topic form. Inquiry activities used in the textbooks are 11 type, however most of that is interpretation of data, experiment, survey and discussion. Ninety six percents of the experiment, belong to the 1st level, four percents of that belong to the 2nd level of the Schwab's inquiry level and there are no activities of the 3rd level. Little attention is given to Goal Cluster I, II, IV in the common science textbooks currently employed. Its content should be broadened to include all Goal Clusters of Project Synthesis. Homey's indices representing the degrees of student involvement. are $0.57{\sim}1.14$ for sentence analysis, $0.60{\sim}1.67$ for figure and diagram analysis, $0.67{\sim}1.50$ for analysis of questions at chapter ends, respectively, student activity per page investigated being $0.6{\sim}0.9$. But chapter summaries cease to repeats the conclusions of the chapter also it be rather formally and inattentively written.

  • PDF

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

The study of awareness and practice of infection control on dental practitioners during the prosthodontic treatment (치과 보철물 제작 과정에서 감염 관리에 관한 치과 종사자의 인지도 및 실천도에 대한 연구)

  • Jeon, Han-Sol;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.189-197
    • /
    • 2015
  • Purpose: The aim of this study was to assess the degree of awareness and actual practice of dental practitioners regarding infection control during prosthodontic treatment. Materials and methods: Study participants were composed of dentists, dental hygienists, dental technicians working at dental university hospital, general hospital, dental hospital and dental clinics in Daejeon, Korea (n=126). The questionnaires included the data on general characteristics, education, awareness and practice of infection control procedures during prosthodontic treatment through personal self-administration survey. Awareness and practice were measured by Likert scale ranging from 1 to 5. Statistical analysis was done by one-way ANOVA. Influence of awareness on practice was estimated by regression analysis. Results: 27.7% of the respondents answered that the infection control education regarding prosthodontic treatment is insufficient. The mean value of awareness and practice of infection control during the prosthodontic treatment were $2.72{\pm}0.80$, $1.58{\pm}0.88$, respectively. The mean value of practice who answered that had education curriculum at college was $1.62{\pm}0.9$, and $1.31{\pm}0.49$ who did not. The mean value of awareness who equipped guideline was $3.01{\pm}0.9$, and $2.56{\pm}0.70$ who did not. Conclusion: 1. The respondents who received the infection control education by college curriculum showed higher degree of practice than the respondents who did not. 2. The respondents who have appropriate infection control guidebook in their workplace showed higher degree of awareness than the respondents who did not. 3. There was a correlation between the awareness and practice of infection control during prosthodontic treatment; the degree of awareness becomes higher, so does the degree of practice. 4. During the prosthodontic treatment, the degree of practice was lower than the degree of awareness on infection control.

The effect of repeated firings on the color of zirconia-based all-ceramic system (반복 소성이 지르코니아 전부도재관의 색조에 미치는 영향)

  • Jang, Jung-Eun;Kim, Mu-Hyon;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of repeated firings on the color of zirconia restoration with different shading method. Materials and methods: Three different types of zirconia frameworks (adding metallic pigments to the initial zirconia powder before sintering (Group NM), dipping the milled frameworks in dissolved coloring agents (Group KI), or application of liner material to the sintered white frameworks (Group KW) were used to support A3 shade dentin porcelain. Repeated firings (3, 5, or 7) were performed, color differences among ceramic specimens were measured using a colorimeter. Repeated measurements analysis of variance (ANOVA) was used to analyze the data for significant difference. The Tukey Honestly Significant Different (HSD) test was used to perform multiple comparisons (${\alpha}$ = .05). Results: 1. $L^*a^*b^*$ values of the ceramic systems were affected by the number of firings (1, 3, 5 or 7 firings) (P < .001) and shading methods (P < .001). 2. As the number of firings increased, the $L^*$ (for all groups) and $a^*$ value (for KW and NM groups) decreased and the $b^*$ value(for all groups) increased. 3. The mean color differences caused by repeated firings were perceptible (${\Delta}E$ > 1) for group KW and KI fired after 3 times, except for group NM fired after 7 times. 4. In order of decreasing ${\Delta}E$ value fired after 7 times, the values were group KI(${\Delta}E$ = 2.26) > group KW (${\Delta}E$ = 1.47) > group NM (${\Delta}E$ = 1.08) (P < .001). Conclusion: Repeated firings influenced the color of the zirconium-oxide all-ceramic specimens with different shading methods.

An experimental study of cutting efficiency of air-driven diamond burs on human tooth (수종 air-turbine 다이아몬드 버의 절삭 효과에 관한 실험적 연구)

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the cutting efficiency of coarse grit diamond burs with air-turbine handpiece on natural tooth. Materials and methods: Four groups of coarse grit diamond bur were selected: Komet (A), Shofu (B), Premier (C), and Mani (D). The extracted maxillary central incisors were used, and ten cuts were made on each specimen, using the rotary diamond burs. The surface of each bur was measured at the upper, middle, and bottom of the bur with confocal laser scanning microscope and imaged with SEM. The data were analyzed with one-way ANOVA and t-test at the significance level of 0.05. Results: The surface roughness was measured. At the A diamond bur, the Sa values were $52.93\;{\mu}m$, $48.32\;{\mu}m$, $46.79\;{\mu}m$, $45.06\;{\mu}m$, and $43.43\;{\mu}m$ for control, test 1, 2, 3, and 4 respectively. The Sa values were $50.68\;{\mu}m$, $45.62\;{\mu}m$, $44.41\;{\mu}m$, $44.10\;{\mu}m$, and $42.46\;{\mu}m$ for B diamond bur, $58.02\;{\mu}m$, $55.53\;{\mu}m$, $52.22\;{\mu}m$, $48.26\;{\mu}m$, and $45.36\;{\mu}m$ for C diamond bur, and $50.11\;{\mu}m$, $46.73\;{\mu}m$, $45.46\;{\mu}m$, $42.58\;{\mu}m$, and $41.80\;{\mu}m$ for D diamond bur. Surface roughness after each bur use showed significant changes, but no significant difference was found in surface roughness change between bur systems. Conclusions: Surface roughness in the same bur system showed significant differences after each tooth preparation. However no statistically significant differences were found in surface roughness between bur systems. The SEM images between control and test 4 showed the abraded particles.

Retentive bond strength of fiber-reinforced composite posts cemented with different surface treatments (Fiber reinforced composite post의 표면 처리에 따른 접착 강도)

  • Roh, Hyunsik;Noh, Kwantae;Woo, Yi-Hyung;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.113-120
    • /
    • 2014
  • This study will evaluate the effectiveness of various pretreatments when fiber-reinforced composite (FRC) post is bonded to endodontically treated tooth with resin cement. Materials and methods: Canal shaping of FRC post (DT Light post, Size 3, Bisco Inc., Schaumburg, IL, USA) was performed on endodontically treated premolars at 1.5 cm from CEJ. Samples were divided into 6 groups of surface treatment after conventional washing and drying to the canal. Total of 24 FRC posts were randomly divided into 6 groups of surface treatment as follows: Group C: control - no surface treatment, Group A: airborne-particle abrasion (Cojet sand, 3M ESPE), Group S: silanization (Bis-silane, Bisco Inc.), Group M: universal primer (Monobond-plus primer, Ivoclar Vivadent Inc.), Group AS: silanization after airborne-particle abrasion, Group AM: universal primer treatment after airborne-particle abrasion. Pretreated fiber posts were cemented with resin-based luting material and photo-polymerized and cut to the thickness of 1 mm. Push-out test using a universal testing machine was performed. Bonding failure strength of post dislodgement was measured and the type of bonding failure was classified. Data were analyzed with Kruskal-Wallis test and multiple comparison groups were performed using Tukey HSD value of rank test (${\alpha}=0.05$). Results: Group AS showed significantly highest bonding strength. Group S, group AM, group A, and group M showed lower bonding strength in order. The control group showed the lowest bonding strength. Conclusion: Surface treatment with silane showed to be the most effective of the surface pretreatment methods for cementation of FRC post. Surface treatment with universal primer showed no significant difference compared with no surface treatment group as for bonding strength.

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.

Osseointegration of zirconia implant in the tibia of pigs (돼지의 경골에 식립된 지르코니아 임플란트의 골유착에 관한 연구)

  • Kim, Lee-Kyoung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.190-198
    • /
    • 2013
  • Purpose: The purposes of this study were to investigate osseointegration around zirconia implants which had machined or alumina sandblasted surface, and to compare the results with titanium implants. Materials and methods: The study was performed on the tibia of 6 pigs. Three types of implants were investigated: group T-titanium implant, group Z-machined zirconia implant, group ZS-alumina sandblasting treated zirconia implant. Zirconia implants were manufactured from yttria-stabilized tetragonal zirconia polycrystalline (Acucera Inc., Pocheon, Korea). A total of 36 implants were installed in pigs' tibias. After 1, 4 and 12 weeks of healing period, the periotest and the histomorphometric analysis were performed. The data were analyzed using one-way ANOVA and significance was assessed by the Scheffe test (${\alpha}=.05$). Results: In the measurement of surface roughness, highest Ra value was measured in group T with significant difference. No significant differences were found among groups regarding Periotest values. After 1 week, in comparison of bone to implant contact (BIC), group Z showed higher value with significant difference. In comparison of bone area (BA), group T and group Z showed higher value with significant difference than group ZS. After 4 weeks, in comparison of BIC, group T showed higher value with significant difference. Comparison of BA showed no significant difference among each implant. After 12 weeks, the highest mean BIC values were found in group T with significant difference. Group ZS showed higher BIC value with significant difference than group Z. In comparison of BA, group T and group ZS showed higher value with significant difference than group Z. Conclusion: Zirconia implant showed low levels of osseointegration in this experiment. Modification of surface structure should be taken into consideration in designing zirconia implants to improve the success rate.