• Title/Summary/Keyword: Manual Measurement

Search Result 453, Processing Time 0.032 seconds

Reliability of measurement devices for measuring the ankle joint motion (발목 관절 가동범위 측정을 위한 측정도구의 신뢰도 연구)

  • Hong, Wan-Sung;Kim, Gi-Won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purposes of this study were to establish the concurrent validity of the universal goniometer and electronic inclinometer for ankle joint of motion, and to determine the inter-tester and the intra-tester reliability of these two instruments. Methods: Subjects were instructed 25 healthy subjects. Ankle range of motion was measured on two separate occasions 2 or 3 days by two physical therapists. Ankle dorsiflexion and plantarflexion was by using an universal goniometer and an electronic inclinometer. Results: The Pearson product-moment correlation between the two instruments was 0.78~0.80. The ICCs for inter-tester reliability ranged from 0.63 to 0.73 for universal goniometer and ranged from 0.81 to 0.88 for electric inclinometer. The ICCs for intra-tester reliability showed a wide variation(ICC=0.61 to 0.86). Conclusion: These findings indicate that the two instruments are reliable instruments for measuring ankle joint range of motion. The results also indicate that the two instruments can be used interchangeably for measuring ankle motions.

  • PDF

The study on the physical characteristics of soccer player with Yangdorak (프로 축구선수의 양도락 분석을 통한 신체특성 연구)

  • Heo, Seung-Jin;Lim, Chang-Sun;Yim, Jun-Hyok
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.1
    • /
    • pp.11-22
    • /
    • 2010
  • Object: This study was planned to show the physical characteristics of soccer player and their Yangdorak measurements. Method: We categorized 5 study group. (I-Players classified by age; II, III-Players and control group; IV-Players who had positive RF and the others; V-Players who had digestive disorder and the others) And We conducted the potentiality of skin resistance(Yangdorak) and GFS, PFT, ECG and the other, then analysis that. Result: As old aged group, Yangdorak shown lower RS, but that was not significant. Player group had higher Yangdorak score at H5, F1, F2, F5 than control group. Player group was shown better cardiopulmonary function, but H1, H2, H3 score were not significant. Players who conducted RF test shown not significant difference of H4 measurement between positive and negative group. Digestive disorder group had higher F1, F6 score, but that wasn't significant.

  • PDF

The Effect of Taping and Stretching Exercise on Muscle Strength and Endurance of Knee Flexors and Extensors (테이핑과 신장운동이 슬관절 굴곡근과 신전근의 근력 및 근지구력에 미치는 영향)

  • Lee, Ho-Jae;Hyun, Sang-Wook;Seo, Hyun-Kyu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose : to investigate change of isokinetic muscle strength and isokinetic muscle endurance of quadriceps femoris and hamstring after application of taping and static stretching. Methods : For this study, 14 male members of college soccer team participated in this research. Participants were divided into two groups: seven was assigned to a taping group(n=7) and the others were assigned to a static stretching exercise group(n=7). Main outcome was measured by using biodex. The isokinetic muscle strength test was processed at the speed of the $60^{\circ}$/sec five times, and isokinetic muscle endurance was processed at the speed of $180^{\circ}$/sec ten times. Results : From the outcomes of the measurement, the results show that there is a more significant difference in the taping group than in a static stretching exercise group. Conclusion : These results will be utilized for the preliminaries in the future.

  • PDF

Map Error Measuring Mechanism Design and Algorithm Robust to Lidar Sparsity (라이다 점군 밀도에 강인한 맵 오차 측정 기구 설계 및 알고리즘)

  • Jung, Sangwoo;Jung, Minwoo;Kim, Ayoung
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.3
    • /
    • pp.189-198
    • /
    • 2021
  • In this paper, we introduce the software/hardware system that can reliably calculate the distance from sensor to the model regardless of point cloud density. As the 3d point cloud map is widely adopted for SLAM and computer vision, the accuracy of point cloud map is of great importance. However, the 3D point cloud map obtained from Lidar may reveal different point cloud density depending on the choice of sensor, measurement distance and the object shape. Currently, when measuring map accuracy, high reflective bands are used to generate specific points in point cloud map where distances are measured manually. This manual process is time and labor consuming being highly affected by Lidar sparsity level. To overcome these problems, this paper presents a hardware design that leverage high intensity point from three planar surface. Furthermore, by calculating distance from sensor to the device, we verified that the automated method is much faster than the manual procedure and robust to sparsity by testing with RGB-D camera and Lidar. As will be shown, the system performance is not limited to indoor environment by progressing the experiment using Lidar sensor at outdoor environment.

Effects of HR-AC Techniques and Kinesio Taping on Pain Changes in Delayed Onset Muscle Soreness (지연성근육통에 적용한 HR-AC기법과 키네시오 테이핑이 통증 변화에 미치는 영향)

  • Bae, Sea-hyun;Kim, Kyung-yoon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Background: This study aimed to investigate the effect of hold-relax and antagonist contraction (HR-AC) technique and Kinesio taping on pain changes in delayed-onset muscle soreness (DOMS) of 20's adults. Methods: Based on voluntary participation, 14 participants with induced-DOMS were randomly divided into control (non-treatment, n=7) and experiment group (HR-AC technique and kinesio taping, n=7). Measurement were used visual analogue scale (VAS), heart rate variability (HRV), and brain wave (alpha). There were 5 sets of the HR-AC technique application on the 5th day from the day of DOMS induction (rest for 30s between sets). Kinesio taping was applied to the same area after HR-AC. Results: The VAS showed significant changes according to the period and in the interaction between the period and the group (p<.01). HRV and alpha wave (Fp1) showed significant changes according to the period (p<.001). The analgesic effect was more rapid and continuous in the experimental group than in the control group. Conclusion: This study showed that the HR-AC technique and Kinesio taping are effective interventions for the management of pain and stress caused by DOMS.

Effects of Hip Joint Mobilization on Pain, Balance, and Gait in Patients with Patellofemoral Pain Syndrome (고관절 가동술이 슬개대퇴통증증후군 환자의 통증, 균형 및 보행에 미치는 영향)

  • Jeong, Eui-young;Park, Si-hyun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-39
    • /
    • 2021
  • Background: Patellofemoral pain syndrome (PFPS) is common knee disorder encountered in clinical: notably, altered hip biomechanic may contribute to PFPS. In this study, We investigated the effects of hip joint mobilization on pain, balance, and gait in patients with PFPS. Methods: Patients were randomly assigned to a control group (n=18) or an experimental group (n=20). Both groups received exercise therapy thrice a week for 4 weeks. The experimental group performed additional hip joint mobilization thrice a week for 4 weeks. Measurement were obtained in each patient pre-intervention and post-intervention (after 4 weeks). Results: The assessed items included the visual analog scale (VAS), one leg standing test (OLS), timed up and go test (TUG), and the 10m walk test (10MWT). Post-intervention assessment showed significantly improved results in both groups (p<.01). A significant intergroup difference was observed only in the results of the 10MWT (p<.05). Conclusion: Our results indicate that hip joint mobilization with exercise therapy may be useful to improve PFPS.

The Correlation Among the Activity of Daily Living, the Manual Ability and the Gross Motor Function (뇌성마비 아동의 일상생활활동 수행능력과 사물조작기능, 대동작기능의 상관관계 연구)

  • Ko, Yu-Jeong
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.10 no.1
    • /
    • pp.11-20
    • /
    • 2012
  • Objective : The purpose of this study is intended to provide useful information about the disability evaluation indicators, the Modified Barthel Index (MBI) as a measurement tool for assessing the ability to perform activities of daily living through the correlation between the Modified Barthel Index (MBI) and the Manual Ability Classification System (MACS), and Gross Motor Function Classification System (GMFCS). Methods : The subject was 82 children with cerebral palsy. The validity was aexamined by calculation of correlation between the Modified Barthel Index (MBI), the Manual Ability Classification System (MACS) and Gross Motor Function Classification System (GMFCS). Results : There were a good significant correlation between the MBI and MACS (r = -.765, p <0.001), the MBI and the GMFCS (r = -.851, p < 0.001) and the MACS and the GMFCS (r = .615, p <0.001). Conclusion : The close correlation between the MBI that is used as the basis of grading cerebral palsy and high reliability and validity of the MACS, GMFCS suggest that disability evaluation indicators, the MBI could be useful for children with disabilities.

  • PDF

Total Intracranial Volume Measurement for Children by Using an Automatized Program (자동화 프로그램을 이용한 아동의 전체두개강내용적 평가)

  • Lee, Jeonghwan;Kim, Ji-Eun;Im, Sungjin;Ju, Gawon;Kim, Siekyeong;Son, Jung-Woo;Shin, Chul-Jin;Lee, Sang-Ick;Ghim, Hei-Rhee
    • Korean Journal of Biological Psychiatry
    • /
    • v.21 no.3
    • /
    • pp.81-86
    • /
    • 2014
  • Objectives Total intracranial volume (TIV) is a major nuisance of neuroimaging research for interindividual differences of brain structure and function. Authors intended to prove the reliability of the atlas scaling factor (ASF) method for TIV estimation in FreeSurfer by comparing it with the results of manual tracing as reference method. Methods The TIVs of 26 normal children and 26 children with attention-deficit hyperactivity disorder (ADHD) were obtained by using FreeSurfer reconstruction and manual tracing with T1-weighted images. Manual tracing performed in every 10th slice of MRI dataset from midline of sagittal plane by one researcher who was blinded from clinical data. Another reseacher performed manual tracing independently for randomly selected 20 dataset to verify interrater reliability. Results The interrater reliability was excellent (intraclass coefficient = 0.91, p < 7.1e-07). There were no significant differences of age and gender distribution between normal and ADHD groups. No significant differences were found between TIVs from ASF method and manual tracing. Strong correlation between TIVs from 2 different methods were shown (r = 0.90, p < 2.2e-16). Conclusions The ASF method for TIV estimation by using FreeSurfer showed good agreement with the reference method. We can use the TIV from ASF method for correction in analysis of structural and functional neuroimaging studies with not only elderly subjects but also children, even with ADHD.

Correlation of XE-2100, ADVIA-120 and Manual Differential Count and Evaluation of Morphology Flag (자동혈구분석기 XE-2100, ADVIA-120와 Manual Differential Count의 상관성 및 Morphology Flag 평가)

  • Lee, Bum Hee;Byun, Nam Sub;Gee, Myung Suk;Song, Soon Young;You, Seon Woo;Park, Hyo Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • With technological advances in automatic hematology analyzers, primary and screening differential counts of white blood cells (WBC) are done with automatic hematology analyzers. They are using different measurement and analysis principles, so differences in WBC differentials and WBC morphology flag exist. This study was carried out to analyze WBC differential counts and WBC morphology flags comparing them with the manual method. Patient EDTA samples in Vacutainer requested for WBC differentials were analyzed with XE-2100. And those samples with suspect flags messages index over 100 were selected and were analyzed with ADVIA-120. Peripheral blood smear film was subsequently made. Three investigators counted 200 cells each (600 cells) in 111 Wright-Giemsa stained blood films. Between two automatic hematology analyzers, neutrophil, lymphocyte, eosinophil, and monocyte showed good correlations, but basophil had moderate correlation. Among automatic hematology analyzers and manual count, neutrophil, lymphocyte, and eosinophil had good correlations, but monocyte had moderate correlation. XE-2100 had higher monocyte, which was due to atypical lymphocyte and myeloblast. LUC in ADVIA-120 was not due to monocyte in XE-2100. Morphology flagging rates were 146.9% in XE-2100 and was 93.2% in ADVIA-120. Positive predictive values of morphology flag were 58.2% in XE-2100 and 54.4% in ADVIA-120. Flags such as atypical lymphocyte, immature granulocyte, and left shift had higher predictive values and those such as N-RBC, platelets clump, and blast had lower ones. Between automatic hematology analyzers, WBC differentials showed good correlations. Predictive values for morphology flags can be variable with changing criteria. Reviewing criteria for WBC differentials and morphology flags should be established in each laboratory with regards to size of laboratory and patients it serves.

  • PDF

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.