• Title/Summary/Keyword: MU simulator

Search Result 148, Processing Time 0.025 seconds

Design of 1.9GHz CMOS RF Up-conversion Mixer (1.9GHz CMOS RF Up-conversion 믹서 설계)

  • Choi, Jin-Young
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.202-211
    • /
    • 2000
  • Utilizing the circuit simulator SPICE, we designed a 1.9GHz CMOS up-conversion mixer and explained in detail the simulation procedures including device modeling for the circuit design. Since the measured characteristics of the chip fabricated using the $0.5{\mu}m$ standard CMOS process had shown a big deviation from the characteristics expected by the original simulations, we tried to figure out the proper reasons for the discrepancies. Simulations considering the discovered problems in the original simulations have shown the validity of the simulation method tried for the design. We have shown that the utilized standard CMOS process can be used for the implementation of the chip characteristics similar to those of the equivalent chip fabricated using the GaAs MESFET process.

  • PDF

Calibration Study on the DC Characteristics of GaAs-based $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ Heterostructure Metamorphic HEMTs (GaAs 기반 $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ 이종접합 구조를 갖는 MHEMT 소자의 DC 특성에 대한 calibration 연구)

  • Son, Myung-Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.63-73
    • /
    • 2011
  • Metamorphic HEMTs (MHEMTs) have emerged as excellent challenges for the design and fabrication of high-speed HEMTs for millimeter-wave applications. Some of improvements result from improved mobility and larger conduction band discontinuity in the channel, leading to more efficient modulation doping, better confinement, and better device performance compared with conventional pseudomorphic HEMTs (PHEMTs). For the optimized device design and development, we have performed the calibration on the DC characteristics of our fabricated 0.1 ${\mu}m$ ${\Gamma}$-gate MHEMT device having the modulation-doped $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}$As heterostructure on the GaAs wafer using the hydrodynamic transport model of a commercial 2D ISE-DESSIS device simulator. The well-calibrated device simulation shows very good agreement with the DC characteristic of the 0.1 ${\mu}m$ ${\Gamma}$-gate MHEMT device. We expect that our calibration result can help design over-100-GHz MHEMT devices for better device performance.

Analysis of Decoupling Capacitor for High Frequency Systems

  • Jung, Y.C.;Hong, K.K.;Kim, H.M.;Hong, S.K.;Kim, C.J.
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.437-438
    • /
    • 2007
  • In this paper a embedded decoupling capacitor design with gap structure will be discussed. A novel structure is modeling and analization by High Frequency Structure Simulator (HFSS). Proposed capacitor have $2m{\times}2m$ in rectangular shape. The film thickness of copper/dielectric film/substrate is respectively 35um/20um/35um. A dielectric layer of BaTiO3/epoxy has the relative permittivity of 25. Compare of the planar decoupling capacitor, capacitance densities of this structure in the range of $55{\mu}F$/mm2 have been obtained with 50um gap while capacitance densities of planar structure $55{\mu}F$/mm2 in the same size. The frequency dependent behavior of capacitors is numerically extracted over a wide frequency bandwidth 500MHz-7GHz. The decoupling capacitor can work at high frequency band increasing the gap size.

  • PDF

Effective Lithography Simulator for Extraction of Photoresist Exposure Parameter (감광제의 노광변수 추출을 위한 효율적인 전산모사기)

  • Kim, Sang-Kon;Byun, Sung-Hwan;Jeong, Yeon-Un;Cho, Sun-Youg;Oh, Jin-Kyung;Lee, Young-Mi;Lee, Eun-Mi;Sung, Moon-Gyu;Sohn, Young-Soo;Oh, Hye-Keun
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.569-572
    • /
    • 1998
  • The semiconductor technology for the deep submicron $regime(0.18\mu\textrm{m})$ and larger wafer $diameters(300\mu\textrm{m})$ has been increased its cost with each wafer. Hence, in order to reduce the number of characterization experiments of a new process, lithographic modeling is more important than it was. In this paper, we introduced a new method to extract Dill ABC parameters from the refractive index changes. In order to evaluate our exact method, results of experiments and calculations for several resists were compared with other methods〔1〕through the lithographic simulation.

  • PDF

A Study on Estimation of Motor Unit Location of Biceps Brachii Muscle using Surface Electromyogram (표면 근전도를 이용한 이두박근의 운동단위 위치 추정에 관한 연구)

  • Park, Jung-Ho;Lee, Ho-Yong;Jung, Chul-Ki;Lee, Jin;Kim, Sung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.28-39
    • /
    • 2010
  • In this paper, a new method to estimate MU (motor unit) location in the short head of BIC (biceps brachii) muscle using surface EMG (electromyogram) is proposed. The SMUAP (single motor unit action potential) is generated from a MU located at certain depth from the skin surface. The depth is referred as MU location. For estimating muscle force precisely, the information of the MU location is required. The reference SMUAPs are simulated based on anatomical structure of human muscle, and compared with acquired real EMG signals using 3-channel surface EMG electrode. The proposed method was compared with the results of previous researchers and verified its accuracy by computer simulation. From the simulation result in case of the MU located in 8[mm], the average estimation error of proposed method was 0.01[mm]. But the average estimation error of Roeleveld's method was 2.33[mm] and Akazawa's method was 1.70[mm]. Therefore the proposed method was more accurate than the methods of previous researchers.

The basic experiments for the fabrication of the SPUDT type Inter using the SFIT type filter (SFIT형태를 이용한 SPUDT형 필터제작에 관한 기초실험)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1916-1923
    • /
    • 2007
  • We have studied to obtain the SAW filter for the passband was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and thin we performed computer-simulated by simulator. We cm fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift of the SAW filter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are $5000\;{\AA}$ and $3.6{\mu}m$ respectively. And we have employed that the distances from the hot electrode to the reflector are $2.0{\mu}m$, $2.4{\mu}m$ and the distance from the hot electrode to the ground is $1.5{\mu}m$ respectively. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 7,8MHz. And we could obtain that return loss is less then -18dB, ripple characteristics is probably 3dB and triple transit echo is less then -25dB after when we have matched impedance.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

X77-Design and Construction of a Computer System

  • Park, Cheol-Hui;Choe, Gwang-Mu;Lee, Jeon-Yeong;Lee, Yong-Seok;Song, Sang-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.94-103
    • /
    • 1979
  • A 16-bit computer system, called X77, is designed and constructed using bit-slice micro-slice microprogrammable. A cross-assembler/simulator software has been implemented and used to debug the entire system design including actual microcodes prior to hardware realizations. Prototypes of X77 CPU, I/O processing subsystem and their interconnections have been constructed and are in the process of being debugged.

  • PDF

A Study on the PN Junction Breakdown Characteristics with Design and Process Parameters of FLR in Power Device Design (전력 반도체 소자의 설계에 있어서 FLR의 Design 및 Process Parameter에 따른 PN접합의 항복특성에 관한 고찰)

  • Song, Dae-Sik;Kang, Ey-Goo;Hwang, Sang-Joon;Sung, Man-Young;Lee, Cheol-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1146-1148
    • /
    • 1995
  • To improve the breakdown characteristics of vertical power devices, field limiting ring(FLR) is popularly used. In this paper, at vertical power device having $300{\sim}600V$ breakdown voltage, FLR thecnique is considered, by two dimensional computer simulator, with the various of parameters; number of FLR, seperation distance of first FLR from the main juncton and second FLR from the first FLR, doping concentration and thickness of epi-layer, etc.. Below $40{\mu}m$ epi thickness, and for the case of one FLR, the maximum breakdown voltage, 580V is obtained.

  • PDF