• 제목/요약/키워드: MR contrast agent

검색결과 59건 처리시간 0.026초

Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

  • Lee, Youngjin;Choi, Min Hyeok;Goh, Hee Jin;Han, Dong-Kyoon
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.281-285
    • /
    • 2016
  • The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmol/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.

가돌리늄 조영제 주입에 따른 1H-MRS spectrum의 정량적 비교 (Quantitative Comparison of 1H-MRS Spectra Depending on the Paramagnetic Gadolinium Contrast Agent(GBCA) Injection)

  • 최관우;손순룡;유병규
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.589-595
    • /
    • 2017
  • 본 연구는 1H-MRS 검사 시 조영제 사용이 대사물질의 spectrum에 어떤 영향을 미치는지 비교 분석함으로써, 조영제 주입 후 MRS 시행의 가능성을 알아보고자 하였다. 연구방법은 2017년 1월부터 동년 5월까지 뇌 MRI 검사를 시행한 30명을 대상으로, 조영제 주입 전, 후 전두엽 백질 부분의 spectrum을 획득하여 뇌 조직의 대사물질 spectrum을 비교평가 하였다. 연구결과, 조영제를 주입할 경우 각 대사물질의 spectrum은 통계적으로 의미가 없어 조영제 사용이 대사물질의 spectrum에 영향을 미치지 않음을 알 수 있었다. 결론적으로 대조도가 떨어져 병변의 위치파악이 힘든 경우 정확한 위치의 spectrum을 얻기 위해선 조영제를 사용하여 대조도를 높인 다음 MRS를 시행하는 것이 바람직 할 것으로 사료된다.

조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가 (Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent)

  • 최관우;서성미;손순룡
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.5124-5130
    • /
    • 2014
  • 조영제의 희석률 변화에 따른 신호강도를 분석하여 조영증강 자기공명혈관조영검사 시 점도와 삼투압에 따른 부작용을 최소화하고 신호강도를 높여 영상의 질을 향상시키고자 하였다. 연구방법은 조영제가 혈관에 주입되면 혈액과 희석되어 mol 농도가 변화되고, 그에 따라 신호강도의 변화를 일으킴에 착안하여 phantom을 제작하였다. phantom 결과를 바탕으로 임상실험은 2013년 11월부터 2014년 1월까지 조영제를 희석한 군(30명)과 희석하지 않은 군(30명)으로 구분하여 뇌혈관의 신호강도를 비교하였다. 연구결과, 조영제 mol 농도 변화에 따른 phantom의 신호강도는 0.0125mmol부터 급격히 증가하다 20mmol에서 최고점을 이룬 후 200mmol부터 평형을 이루었다. 임상실험에서도 조영제를 희석하여 검사한 영상의 신호강도가 모두 높게 나타나, 1000mmol 조영제 사용에 비해 500mmol로 희석하여 사용함이 최고점인 20mmol에 근접하여 우수함을 알 수 있었다. 결론적으로 조영제를 희석하여 사용함으로써 점도와 삼투압을 저하시키고, 영상의 질을 향상시킬 수 있었으므로 임상적용의 유용성이 높다고 할 수 있다.

자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성 (Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.49-56
    • /
    • 2001
  • 목적 자기공명 담관췌장조영술(MR Cholangiopancreatography, 이하 MRCP)에서 음성 경구 조영제로 사용한 초상자성 산화철 (Superparamagnetic iron oxide, SPIO) 제제의 유용성을 영상 질의 향상 효과를 통하여 알아보고자 하였다. 대상 및 방법: 임상소견, 이학적 검사 및 초음파 검사에서 담도와 췌장질환이 의심되었던 48명의 환자와 자원자 6명을 대상으로 하였다 음성 경구 조영제로 사용한 SPIO 제재의 적정 농도의 선택을 위해 정주용 SPIO제재 0.5ml, 0.75m1, 1 ml, 1.5 ml 및 2ml을 500m1 물에 희석시켜 가상 실험을 통하여 72강조영상에서 물의 신호강도가 완전히 소실되는 최소농도를 산출하였다. MRCP영상은 1.57를 이용하여 지방억제 HASTE (half-courier acquisition single-shot turbo spin echo) 와 터보스핀에코(Turbo spin echo) 기법을 이용하여 얻었다. 조영 후 영상은 음성 경구 조영제 300m1를 경구 섭취하고 10분 후에 얻었고, 조영 전 후 영상을 최대 신호 투영법으로 재구성하였다. 영상 분석은 조영 전 영상에 비교하여 위 십이지장내의 액체의 고신호강도에 따른 총수담판 및 췌관의 묘출의 방해 정도 및 진단의 향상 정도를 두 명의 방사선과 의사가 합의하여 정성적으로 분석하였다. 결과: 가상 실험에서, 22.4 ugFe/ml 농도의 혼합액 (Feridex I ml 용액을 자유수 500m1에 희석하여 만든 농도)에서의 신호강도 소실 백분율의 증가가 가장 현저한 변화를 보였다. 영상분석에서는, 조영 후 영상이 조영 전 영상에 비해 영상의 질이 향상되었다. 또한 환자의 25% (12/48)에서 조영 전 영상에 비하여 더 정화한 진단을 가능하게 하였다. 결론. MRCP영상 획득 시 음성 경구 조명제로서 사용된 초상자성 산화철 (SPIO) 제재는 영상질의 향상시켜 담도 및 췌장질환을 평가하는데 유용할 것으로 사료된다.

  • PDF

The Determination of Take-Off Time in Iteration on Dynamic Susceptibility Contrast Agent MR Perfusion Imaging

  • 김대원;류완석;정성택
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.79-80
    • /
    • 2003
  • In existing method, the threshold has determined the points to be used in extrapolation and only pre-peak points were used to find t0. However, to reduce error in using this fitting method, in this study, finding t0is considered the correlation between fitting result and each profile in using iteration method. And the proposed method is compared with the existing method.

  • PDF

새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구 (The Synthesis and MR Properties of New Macromolecular MR Contrast Agent)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • 제6권1호
    • /
    • pp.35-40
    • /
    • 2002
  • 목적 : 새로운 개념의 macromolecular MR 조영제를 개발하여 자기이완적 특성 및 조직특이성 조영제로서의 가능성을 탐색해 보고자 하였다. 대상 및 방법 : Phthalocyanine (PC)을 상자성 원소의 배위자로 선택하였다. 2.01g (5.2 mmol)의 Phthalocyanine을 0.37 g(1.4mmo1)의 Mn chloride와 $310^{\circ}C$에서 36시간동안 반응시킨 후 혼합물을 크로마토그래피(CHC13/CH3OH 98/2 v/v, Rf, 0.76)로 정제하여 1.04 g (46%)의 MnPC (분자량 2000)를 얻었다. 0.1 mM로 희석시킨 MnPC를 1.5T(64MHz) MR 장비를 이용하여 T1/T2 자기이완율을 측정하였다. MnPC의 MR 영상 특성을 알아보기위해 1.5T MRI에서 스핀반향 기법(TR/TE= 500/14 msec)과 경사에코 기법중 FLASH 기법(TR/TE=80/4 msec, flip angle=60)을 사용하여 매 10분 간격으로 최고 4시간까지 연속적으로 토끼의 간에서 영상을 획득하였다. 농도별 차이를 알아보기위해 MnPC를 20 mM, 50 mM, 100 mM로 희석하여 사용하였다. 결과 : MnPC의 1.5 T(64 MHz)에서의 자기이완율은 Rl : 7.28 $mM^{-1}S^{-1}$, R2=55.56 $mM^{-1}S^{-1}$으로 small molecular weight 조영제인 Gd-DTPA의 Rl(=4.8 $mM^{-1}S^{-1}$), R2(=5.2 $mM^{-1}S^{-1}$) 값과 비교할 때 T1/T2 자기이완율이 매우 컸다. 스핀반향과 FlASH 기법 모두에서 조영증강은 조영제 주사후 약 10분 정도에 최고치에 달한 후 약 2시간 정도까지 유지하였다. MnPC는 small molecular weight의 간특이성 조영제들인 Gd-EOB-DTPA, Gd-BOPTA 및 MnDPDP과 비교할 때 조명증강을 유지하는 시간이 훨씬 더 긴 특성을 보였다. MnPC는 시간 경과에 따라 담도로 배출되었다. 결론 : 새로운 종류의 macromolecular MR agent인 MnPC를 자체 개발하였고 자기이완율을 측정한 결과 T1/T2 효과가 기존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다.

  • PDF

1.0Tesla 자기공명 영상장치에서의 혈관조영기법에 관한 연구 (MR Angiography at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;김종효
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.528-532
    • /
    • 1997
  • X-Ray Angiography has been gold standard or imaging of blood flow. However, patients have to take many risks such as catheterization procedure, iodine contrast agent and ionizing X-rays. MR Angiography has been suggested as a substitute for its non-hazard to patient. But the resolution and contrast was inferior to that of X-ray Angiography. Recently the resolution and the contrast have been much improved due to the development of fast imaging technique.

  • PDF

고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성 (The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography)

  • 최관우;김윤신;손순룡;이호범;나사라;민정환;유병규;이종석
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5682-5688
    • /
    • 2013
  • 본 연구는 고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 1mmol/mL 조영제를 사용함으로써 현재 대다수의 의료기관에서 사용하고 있는 0.5mmol/ml 조영제 대비 신호대잡음비와 대조도대잡음비를 높여 진단적 가치를 극대화 시키는데 목적을 두었다. 연구방법은 2012년 1월부터 2013년 6월까지 가돌리늄 함유량에 따른 대조도 차이를 알아보기 위하여 0.5mmol/mL 함유량을 가진 기존의 조영제를 사용한 20명과 1mmol/mL 함유량을 가진 새로운 조영제를 사용한 27명 등 총 47명의 환자를 연구대상으로 하였으며, 고관절의 관절공간과 인접한 근육조직인 장요근, 그리고 대퇴골두의 신호강도를 각각 측정한 후 신호대잡음비와 대조도대잡음비를 비교 평가하였다. 연구 결과, 가돌리늄 함유량이 높은 1mmol/mL 조영제 사용 시 SNR은 관절공간 27.00%(p<.01), 대퇴골두 30.01%(p<.01), 장요근 18.74%(p>.05) 높았고, 대조도대잡음비 또한 신호대잡음비와 같이 관절공간과 장요근, 관절공간과 대퇴골두 모두 28.31%(p<.01)와 26.74%(p<.01)로 높았다. 결론적으로 단위 부피당 가돌리늄 함유량이 높은 1mmol/mL 조영제를 사용하면 높은 T1 단축효과로 인해 신호강도가 커지고 대조도 차이가 큰 영상을 획득 할 수 있어, 진단적 가치가 높은 영상을 얻을 수 있다. 본 연구는 고관절의 자기공명관절조영검사에 대한 1mmol/mL 조영제의 유용성을 최초로 증명하여 진단적 가치를 높일 수 있는 방안을 제시하였다는 데에 학문적 가치가 크다고 하겠다.

Evaluation by Contrast-Enhanced MR Imaging of the Lateral Border Zone in Reperfused Myocardial Infarction in a Cat Model

  • Ae Kyung Jeong;Sang Il Choi;Dong Hun Kim;Sung Bin Park;Seoung Soo Lee;Seong Hoon Choi;Tae-Hwan Lim
    • Korean Journal of Radiology
    • /
    • 제2권1호
    • /
    • pp.21-27
    • /
    • 2001
  • Objective: To identify and evaluate the lateral border zone by comparing the size and distribution of the abnormal signal area demonstrated by MR imaging with the infarct area revealed by pathological examination in a reperfused myocardial infarction cat model. Materials and Methods: In eight cats, the left anterior descending coronary artery was occluded for 90 minutes, and this was followed by 90 minutes of reperfusion. ECG-triggered breath-hold turbo spin-echo T2-weighted MR images were initially obtained along the short axis of the heart before the administration of contrast media. After the injection of Gadomer-17 and Gadophrin-2, contrast-enhanced T1-weighted MR images were obtained for three hours. The size of the abnormal signal area seen on each image was compared with that of the infarct area after TTC staining. To assess ultrastructural changes in the myocardium at the infarct area, lateral border zone and normal myocardium, electron microscopic examination was performed. Results: The high signal area seen on T2-weighted images and the enhanced area seen on Gadomer-17-enhanced T1WI were larger than the enhanced area on Gadophrin-2-enhanced T1WI and the infarct area revealed by TTC staining; the difference was expressed as a percentage of the size of the total left ventricle mass (T2= 39.2 %; Gadomer-17 =37.25 % vs Gadophrin-2 = 29.6 %; TTC staining = 28.2 %; p < 0.05). The ultrastructural changes seen at the lateral border zone were compatible with reversible myocardial damage. Conclusion: In a reperfused myocardial infarction cat model, the presence and size of the lateral border zone can be determined by means of Gadomer-17- and Gadophrin-2-enhanced MR imaging.

  • PDF

뇌척수액 미세순환을 통한 래트 내이 외림프의 가돌리늄 조영제 증강 특성 (Enhancement Characteristics of Gadolinium Contrast Agent in the Rat Inner Ear Perilymph through CSF microcirculation)

  • 김민정;이상열;이희중;이태관;장용민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.193-198
    • /
    • 2022
  • Contrast enhanced magnetic resonance imaging using gadolinium-based contrast agent (GBCA) is a very useful in vivo technique to visualize the inner ear pathology including endolymphatic hydrops. Although systemic intravenous (IV) administration can visualize the perilymph space, the visualization was possible by indirect passage of contrast agent through blood-perilymph barrier. All animal experimental procedures were performed under anesthesia with 5% isoflurane. Lipopolysaccharide (LPS) was instilled into the left tympanic cavity through the tympanic membrane using a sterile 27gauge needle to induce hydrops model. Tucker-Davis Technologies system was used to measure Auditory Brainstem Responses (ABRs). For intracerebroven-tricular (ICV) administration, 25 µmol of GADOVIST (Bayer, Berlin, Germany) was used and diluted GADOVIST injection was 10 µl. MR imaging was acquired with a 9.4 Tesla MRI scanner. Transmit-receive volume coil with 40 mm inner diameter and 75 mm out diameter was used. ICV administration well demonstrated the strong enhancement along the cerebrospinal fluid (CSF) microcirculation pathway including CSF fluid in the subarachnoid space and CSF space of the inner ear structures. On the other hand, IV administration showed no contrast enhancement along the CSF microcirculation pathway and showed weak enhancement in the inner ear structures. In case of rat hydrops model, ICV administration showed that the reduced contrast enhancement in the perilymph space of the hydrops induced inner ear compared to the contrast enhancement in the perilymph space of the normal inner ear. New systemic ICV administration method provide contrast enhancement of GBCA in the inner ear through CSF microcirculation pathway.