COMPUTATIONAL ANTHROPOMORPHIC PHANTOMS FOR RADIATION PROTECTION DOSIMETRY: EVOLUTION AND PROSPECTS

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.239-250
    • /
    • 2006
  • Computational anthropomorphic phantoms are computer models of human anatomy used in the calculation of radiation dose distribution in the human body upon exposure to a radiation source. Depending on the manner to represent human anatomy, they are categorized into two classes: stylized and tomographic phantoms. Stylized phantoms, which have mainly been developed at the Oak Ridge National Laboratory (ORNL), describe human anatomy by using simple mathematical equations of analytical geometry. Several improved stylized phantoms such as male and female adults, pediatric series, and enhanced organ models have been developed following the first hermaphrodite adult stylized phantom, Medical Internal Radiation Dose (MIRD)-5 phantom. Although stylized phantoms have significantly contributed to dosimetry calculation, they provide only approximations of the true anatomical features of the human body and the resulting organ dose distribution. An alternative class of computational phantom, the tomographic phantom, is based upon three-dimensional imaging techniques such as magnetic resonance (MR) imaging and computed tomography (CT). The tomographic phantoms represent the human anatomy with a large number of voxels that are assigned tissue type and organ identity. To date, a total of around 30 tomographic phantoms including male and female adults, pediatric phantoms, and even a pregnant female, have been developed and utilized for realistic radiation dosimetry calculation. They are based on MRI/CT images or sectional color photos from patients, volunteers or cadavers. Several investigators have compared tomographic phantoms with stylized phantoms, and demonstrated the superiority of tomographic phantoms in terms of realistic anatomy and dosimetry calculation. This paper summarizes the history and current status of both stylized and tomographic phantoms, including Korean computational phantoms. Advantages, limitations, and future prospects are also discussed.

근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가 (Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation)

  • 이준성;김양수;김민걸;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가 (Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers)

  • 이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제24권4호
    • /
    • pp.215-223
    • /
    • 1999
  • PWR 원전 증기발생기 수실의 방사선장 특성과 그곳에서 작업하는 종사자의 유효선량을 몬테칼로 시뮬레이션으로 평가하였다. 선원항으로는 고리1호기 증기발생기 방사화물 분석결과가 사용되었으며 유효선량 평가에는 MCNP4A코드와 MIRD형 성별 수학적 인형 모의피폭체가 사용되었다. 수실 내부 방사선장은 U튜브 영역에서 내려오는 방사선이 지배적이었으며 극각에 대해 근사적으로 코사인 분포를 나타내었다 유효선량률은 표준성인과 체격이 작은 성인(이 목적으로 15세 모의피폭체가 사용되었다.)의 경우 각각 36.22$mSvh^{-1}$와 37.06$mSvh^{-1}$로서 체격의 영향은 경미했다. 한편, 모의피폭체의 머리, 가슴 및 하복부에 해당하는 위치에서 평가된 조사선량률과 에너지스펙트럼에 대해 ICRU47에서 주어진 주위선량당량 환산계수를 이용해 평가한 등가선량률은 각각 119, 71, 및 58 $mSvh^{-1}$로 나타났다. 따라서 개인선량계 판독에서 얻는 심부선량 또는 유효선량은 앞서 계산한 유효선량률의 2배 정도가 될 것으로 보인다. 이 사실은 일반적인 개인선량계의 경사입사 방사선에 대한 과대/과소 평가 특성과 함께 비정규, 고선량률 방사선장에 종사하는 작업자의 선량계측 계획 및 결과의 해석에 매우 신중해야 함을 알려준다.

  • PDF

진단X선에 의한 성인의 진단행위별 유효선량평가 (Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult)

  • 김우란;이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제27권3호
    • /
    • pp.155-164
    • /
    • 2002
  • 몬테칼로 모사를 통해 여러 가지 진단X선 검사를 받는 성인의 유효선량을 평가하는 방법체계를 구축하였다. 피사체 인형팬텀으로서 MIRD5 남성 팬텀과 ORNL 여성팬텀이 이용되었고 사용 X선 스펙트럼은 SPEC78 코드로 생산하였다. 같은 진단절차에 대해 NRPB 평가결과와 비교함으로써 계산체계를 검증하였다. 계산체계를 이용하여 흉곽, 복부, 두부 및 척추의 진단에서 AP, PA, LLAT 및 RLAT 방향으로 입사하는 X선에 대한 장기 등가선량과 유효선량을 평가하였으며 가장 보편적인 흉곽 PA와 복부 AP의 경우 유효선량이 각각 0.029mSv와 0.44mSv로 나타났다. 흉곽 PA 1회 촬영 시 피폭하는 선량이 전통적 평가치인 0.3mSv(또는 30mrem)보다 매우 작게 나타나는 것은 진단방사선 기술의 발전뿐만 아니라 적용하는 선량개념의 차이에 기인하는 것으로서 여러 방사선 의료절차에 대한 집중적인 환자선량 평가의 필요성을 강조하는 것이다. 여기서 개발된 선량평가 체계는 CT 선량, 임부의 진단으로 인한 태아의 선량, 소아과 X선에 의한 선공 등 다른 방사선 의료절차에도 용이하게 응용될 수 있다.

Simulation and assessment of 99mTc absorbed dose into internal organs from cardiac perfusion scan

  • Saghar Salari;Abdollah Khorshidi;Jamshid Soltani-Nabipour
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.248-253
    • /
    • 2023
  • Directly, it is not possible to measure the absorbed dose of radiopharmaceuticals in the organs of the human body. Therefore, simulation methods are utilized to estimate the dose in distinct organs. In this study, individual organs were separately considered as the source organ or target organ to calculate the mean absorption dose, which SAF and S factors were then calculated according to the target uptake via MIRD method. Here, 99mTc activity distribution within the target was analyzed using the definition and simulation of ideal organs by summing the fraction of cumulative activities of the heart as source organ. Thus, GATE code was utilized to simulate the Zubal humanoid phantom. To validate the outcomes in comparison to the similar results reported, the accumulation of activity in the main organs of the body was calculated at the moment of injection and cardiac rest condition after 60 min of injection. The results showed the highest dose absorbed into pancreas was about 21%, then gallbladder 18%, kidney 16%, spleen 15%, heart 8%, liver 8%, thyroid 7%, lungs 5% and brain 2%, respectively, after 1 h of injection. This distinct simulation model may also be used for different periods after injection and modifying the prescribed dose.

진단용 방사성동위원소 취급 시 L-block 차폐기구 사용에 따른 핵의학 종사자의 장기 선량평가 (Organ Dose Assessment of Nuclear Medicine Practitioners Using L-Block Shielding Device for Handling Diagnostic Radioisotopes)

  • 강세식;조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.49-55
    • /
    • 2017
  • 의료기관 내 핵의학 종사자는 방사성동위원소 취급 시 사용하는 선원의 종류, 방사능량, 차폐기구의 사용 여부에 따라 종사자 개인별로 광범위한 피폭선량을 나타낼 수 있다. 이에 본 연구에서는 몬테카를로 기법을 기반으로 한 모의실험을 통해 진단용 방사선원 취급 시 종사자의 장기별 선량평가와 L-block 차폐기구 사용에 따른 선량감소효과를 분석하였다. 그 결과, 방사선원의 취급 위치에 근접할수록 높은 장기선량 분포를 나타내었고, ICRP 조직가중치에 따라 유효선량 분포가 상이한 양상을 보였다. 또한 L-block 두께에 따른 선량감소효과는 차폐두께 증가에 따라 지수함수 분포로 감소되는 경향을 나타내었으며, 방사선원별 선량감소효과는 방출하는 감마선 에너지에 비례하여 낮은 차폐효과를 보였다.

한국 성인남성 표준인을 대상으로 한 방사성옥소($^{131}I$)의 S-value 도출 (S-value of Radioiodine($^{131}I$) in Korean Reference Adult Male)

  • 김정훈;임창선;황주호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.41-47
    • /
    • 2008
  • 한국 성인 남성 표준인(Korean Reference Adult Male)의 기초 자료를 이용하여 수학적 모의 피폭체(Mathematical Phantom)를 제작하였다. 또한 이를 이용하여 방사성옥소($^{131}I$)의 각 장기별 S-value를 산출 하였다. 산출된 S-value는 기존 ICRP-23표준인에 근거하여 산출한 MIRD 5, 및 ORNL-TM 8381자료와 비교해 보았다. 그 결과 S-value는 한국 성인 남성 표준인에 기초한 모의 피폭체가 높은 값을 나타냈다. 이는 몸통이라는 특수한 공간에 위치하게 되는 선원장기(source organ) 및 표적장기(target organ)가 함유하고 있는 구성물질도 중요하지만 그에 못지않게 이들이 차지하고 있는 위치 및 방사성핵종의 특성 또한 중요하게 작용한다는 것을 알 수 있었다.

  • PDF

A Review of Computational Phantoms for Quality Assurance in Radiology and Radiotherapy in the Deep-Learning Era

  • Peng, Zhao;Gao, Ning;Wu, Bingzhi;Chen, Zhi;Xu, X. George
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.111-133
    • /
    • 2022
  • The exciting advancement related to the "modeling of digital human" in terms of a computational phantom for radiation dose calculations has to do with the latest hype related to deep learning. The advent of deep learning or artificial intelligence (AI) technology involving convolutional neural networks has brought an unprecedented level of innovation to the field of organ segmentation. In addition, graphics processing units (GPUs) are utilized as boosters for both real-time Monte Carlo simulations and AI-based image segmentation applications. These advancements provide the feasibility of creating three-dimensional (3D) geometric details of the human anatomy from tomographic imaging and performing Monte Carlo radiation transport simulations using increasingly fast and inexpensive computers. This review first introduces the history of three types of computational human phantoms: stylized medical internal radiation dosimetry (MIRD) phantoms, voxelized tomographic phantoms, and boundary representation (BREP) deformable phantoms. Then, the development of a person-specific phantom is demonstrated by introducing AI-based organ autosegmentation technology. Next, a new development in GPU-based Monte Carlo radiation dose calculations is introduced. Examples of applying computational phantoms and a new Monte Carlo code named ARCHER (Accelerated Radiation-transport Computations in Heterogeneous EnviRonments) to problems in radiation protection, imaging, and radiotherapy are presented from research projects performed by students at the Rensselaer Polytechnic Institute (RPI) and University of Science and Technology of China (USTC). Finally, this review discusses challenges and future research opportunities. We found that, owing to the latest computer hardware and AI technology, computational human body models are moving closer to real human anatomy structures for accurate radiation dose calculations.

X선 촬영 시 연령별 장기선량 차이 연구 (Investigation of organ dose difference of age phantoms for medical X-ray examinations)

  • 박상현;이춘식;김우란;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.35-42
    • /
    • 2003
  • 진단 X선 촬영에 의한 소아 및 성인의 장기 등가선량과 유효선량을 구하는 방법론을 개발하였다. 연령에 따른 체격의 차이가 방사선량 분포에 미치는 영향을 평가하기 위해, 식도를 포함한 4개 연령군의 MIRD형 수학적 모의피폭체를 제작하였다. 두 가지의 전형적인 진단 X선 절차인 흉부 PA와 복부 AP 진단 X선 촬영을 모사하여, 연령별 선량을 계산하였다. 흉부 PA 진단 X선 촬영절차에 의해서 환자들은 대략 0.03mSv의 유효선량을 피폭하는 것으로 나타났다. 복부 AP 진단 X선 촬영절차의 경우 연령에 따라서 0.4에서 1.7mSv의 유효선량을 받는 것으로 나타났다. 한정된 조사장을 갖는 방사선에 대해서 선량을 평가했기 때문에, 장기의 위치와 크기, 모양, 그리고 방사선이 입사하는 표면으로부터의 필이 등이 선량 계산에 상당한 영향을 미쳤다. 따라서 진단 X선의 조사장이나 선질의 조절 등을 통해 방호의 최적화를 위한 노력이 중요한 것으로 나타났다. 본 연구에서 개발된 선량계측 절차는 의료방사선 방호의 최적화를 위한 수단으로 활용될 수 있다.

MV X선의 방사선 선량 증강 현상에서 물리적 특성과 이차입자의 발생 (Characterization of Physical Processes and Secondary Particle Generation in Radiation Dose Enhancement for Megavoltage X-rays)

  • 황철환;김정훈
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.791-799
    • /
    • 2019
  • 선량 증강 현상에서 발생하는 물리적 특성과 증강 물질과의 상호 작용으로부터 발생하는 이차입자 생성을 평가하였다. Geant 4, MIRD 두부 팬텀을 이용한 몬테카를로 전산 모사를 진행하였으며, 선형가속기에서 발생되는 4, 6, 10, 15, 18, 25 MV X선을 선원으로 적용하였다. 10, 20, 30 mg/g의 금(aurum), 가돌리늄(gadolinium) 증강 물질을 팬텀 내부 종양에 모사하였으며, 물리적 상호작용의 변화와 이차입자 발생에 따른 입자플루언스와 초기 에너지로부터 방사선가중인자를 고려하여 등가선량을 평가하였다. 방사선 선량 증강 물질에 의한 상호작용은 고 원자번호에서 기인하여 광전효과에 의한 에너지 흡수를 높이는 것으로 나타났으며, 10 MV 이상의 에너지에서는 광핵반응의 증가를 나타내었다. 이로 인해, 팬텀 내부에서 양성자, 중성자와 같은 이차입자 발생의 증가를 보였으며, 중성자에 의한 등가선량이 최대 424.2배 증가하는 것으로 나타났다. 본 연구는 선량 증강 현상에서의 에너지 전달, 흡수의 물리적 과정을 모사하여, 증강 현상에서 발생하는 물리적 특성을 분석하고자 하였다. 이러한 결과는 향후 in-vivo, in-vitro 선량 증강 실험을 위한 기초 자료로 활용될 수 있을 것으로 사료된다.