Computational anthropomorphic phantoms are computer models of human anatomy used in the calculation of radiation dose distribution in the human body upon exposure to a radiation source. Depending on the manner to represent human anatomy, they are categorized into two classes: stylized and tomographic phantoms. Stylized phantoms, which have mainly been developed at the Oak Ridge National Laboratory (ORNL), describe human anatomy by using simple mathematical equations of analytical geometry. Several improved stylized phantoms such as male and female adults, pediatric series, and enhanced organ models have been developed following the first hermaphrodite adult stylized phantom, Medical Internal Radiation Dose (MIRD)-5 phantom. Although stylized phantoms have significantly contributed to dosimetry calculation, they provide only approximations of the true anatomical features of the human body and the resulting organ dose distribution. An alternative class of computational phantom, the tomographic phantom, is based upon three-dimensional imaging techniques such as magnetic resonance (MR) imaging and computed tomography (CT). The tomographic phantoms represent the human anatomy with a large number of voxels that are assigned tissue type and organ identity. To date, a total of around 30 tomographic phantoms including male and female adults, pediatric phantoms, and even a pregnant female, have been developed and utilized for realistic radiation dosimetry calculation. They are based on MRI/CT images or sectional color photos from patients, volunteers or cadavers. Several investigators have compared tomographic phantoms with stylized phantoms, and demonstrated the superiority of tomographic phantoms in terms of realistic anatomy and dosimetry calculation. This paper summarizes the history and current status of both stylized and tomographic phantoms, including Korean computational phantoms. Advantages, limitations, and future prospects are also discussed.
This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.
PWR 원전 증기발생기 수실의 방사선장 특성과 그곳에서 작업하는 종사자의 유효선량을 몬테칼로 시뮬레이션으로 평가하였다. 선원항으로는 고리1호기 증기발생기 방사화물 분석결과가 사용되었으며 유효선량 평가에는 MCNP4A코드와 MIRD형 성별 수학적 인형 모의피폭체가 사용되었다. 수실 내부 방사선장은 U튜브 영역에서 내려오는 방사선이 지배적이었으며 극각에 대해 근사적으로 코사인 분포를 나타내었다 유효선량률은 표준성인과 체격이 작은 성인(이 목적으로 15세 모의피폭체가 사용되었다.)의 경우 각각 36.22$mSvh^{-1}$와 37.06$mSvh^{-1}$로서 체격의 영향은 경미했다. 한편, 모의피폭체의 머리, 가슴 및 하복부에 해당하는 위치에서 평가된 조사선량률과 에너지스펙트럼에 대해 ICRU47에서 주어진 주위선량당량 환산계수를 이용해 평가한 등가선량률은 각각 119, 71, 및 58 $mSvh^{-1}$로 나타났다. 따라서 개인선량계 판독에서 얻는 심부선량 또는 유효선량은 앞서 계산한 유효선량률의 2배 정도가 될 것으로 보인다. 이 사실은 일반적인 개인선량계의 경사입사 방사선에 대한 과대/과소 평가 특성과 함께 비정규, 고선량률 방사선장에 종사하는 작업자의 선량계측 계획 및 결과의 해석에 매우 신중해야 함을 알려준다.
몬테칼로 모사를 통해 여러 가지 진단X선 검사를 받는 성인의 유효선량을 평가하는 방법체계를 구축하였다. 피사체 인형팬텀으로서 MIRD5 남성 팬텀과 ORNL 여성팬텀이 이용되었고 사용 X선 스펙트럼은 SPEC78 코드로 생산하였다. 같은 진단절차에 대해 NRPB 평가결과와 비교함으로써 계산체계를 검증하였다. 계산체계를 이용하여 흉곽, 복부, 두부 및 척추의 진단에서 AP, PA, LLAT 및 RLAT 방향으로 입사하는 X선에 대한 장기 등가선량과 유효선량을 평가하였으며 가장 보편적인 흉곽 PA와 복부 AP의 경우 유효선량이 각각 0.029mSv와 0.44mSv로 나타났다. 흉곽 PA 1회 촬영 시 피폭하는 선량이 전통적 평가치인 0.3mSv(또는 30mrem)보다 매우 작게 나타나는 것은 진단방사선 기술의 발전뿐만 아니라 적용하는 선량개념의 차이에 기인하는 것으로서 여러 방사선 의료절차에 대한 집중적인 환자선량 평가의 필요성을 강조하는 것이다. 여기서 개발된 선량평가 체계는 CT 선량, 임부의 진단으로 인한 태아의 선량, 소아과 X선에 의한 선공 등 다른 방사선 의료절차에도 용이하게 응용될 수 있다.
Directly, it is not possible to measure the absorbed dose of radiopharmaceuticals in the organs of the human body. Therefore, simulation methods are utilized to estimate the dose in distinct organs. In this study, individual organs were separately considered as the source organ or target organ to calculate the mean absorption dose, which SAF and S factors were then calculated according to the target uptake via MIRD method. Here, 99mTc activity distribution within the target was analyzed using the definition and simulation of ideal organs by summing the fraction of cumulative activities of the heart as source organ. Thus, GATE code was utilized to simulate the Zubal humanoid phantom. To validate the outcomes in comparison to the similar results reported, the accumulation of activity in the main organs of the body was calculated at the moment of injection and cardiac rest condition after 60 min of injection. The results showed the highest dose absorbed into pancreas was about 21%, then gallbladder 18%, kidney 16%, spleen 15%, heart 8%, liver 8%, thyroid 7%, lungs 5% and brain 2%, respectively, after 1 h of injection. This distinct simulation model may also be used for different periods after injection and modifying the prescribed dose.
의료기관 내 핵의학 종사자는 방사성동위원소 취급 시 사용하는 선원의 종류, 방사능량, 차폐기구의 사용 여부에 따라 종사자 개인별로 광범위한 피폭선량을 나타낼 수 있다. 이에 본 연구에서는 몬테카를로 기법을 기반으로 한 모의실험을 통해 진단용 방사선원 취급 시 종사자의 장기별 선량평가와 L-block 차폐기구 사용에 따른 선량감소효과를 분석하였다. 그 결과, 방사선원의 취급 위치에 근접할수록 높은 장기선량 분포를 나타내었고, ICRP 조직가중치에 따라 유효선량 분포가 상이한 양상을 보였다. 또한 L-block 두께에 따른 선량감소효과는 차폐두께 증가에 따라 지수함수 분포로 감소되는 경향을 나타내었으며, 방사선원별 선량감소효과는 방출하는 감마선 에너지에 비례하여 낮은 차폐효과를 보였다.
한국 성인 남성 표준인(Korean Reference Adult Male)의 기초 자료를 이용하여 수학적 모의 피폭체(Mathematical Phantom)를 제작하였다. 또한 이를 이용하여 방사성옥소($^{131}I$)의 각 장기별 S-value를 산출 하였다. 산출된 S-value는 기존 ICRP-23표준인에 근거하여 산출한 MIRD 5, 및 ORNL-TM 8381자료와 비교해 보았다. 그 결과 S-value는 한국 성인 남성 표준인에 기초한 모의 피폭체가 높은 값을 나타냈다. 이는 몸통이라는 특수한 공간에 위치하게 되는 선원장기(source organ) 및 표적장기(target organ)가 함유하고 있는 구성물질도 중요하지만 그에 못지않게 이들이 차지하고 있는 위치 및 방사성핵종의 특성 또한 중요하게 작용한다는 것을 알 수 있었다.
Peng, Zhao;Gao, Ning;Wu, Bingzhi;Chen, Zhi;Xu, X. George
Journal of Radiation Protection and Research
/
제47권3호
/
pp.111-133
/
2022
The exciting advancement related to the "modeling of digital human" in terms of a computational phantom for radiation dose calculations has to do with the latest hype related to deep learning. The advent of deep learning or artificial intelligence (AI) technology involving convolutional neural networks has brought an unprecedented level of innovation to the field of organ segmentation. In addition, graphics processing units (GPUs) are utilized as boosters for both real-time Monte Carlo simulations and AI-based image segmentation applications. These advancements provide the feasibility of creating three-dimensional (3D) geometric details of the human anatomy from tomographic imaging and performing Monte Carlo radiation transport simulations using increasingly fast and inexpensive computers. This review first introduces the history of three types of computational human phantoms: stylized medical internal radiation dosimetry (MIRD) phantoms, voxelized tomographic phantoms, and boundary representation (BREP) deformable phantoms. Then, the development of a person-specific phantom is demonstrated by introducing AI-based organ autosegmentation technology. Next, a new development in GPU-based Monte Carlo radiation dose calculations is introduced. Examples of applying computational phantoms and a new Monte Carlo code named ARCHER (Accelerated Radiation-transport Computations in Heterogeneous EnviRonments) to problems in radiation protection, imaging, and radiotherapy are presented from research projects performed by students at the Rensselaer Polytechnic Institute (RPI) and University of Science and Technology of China (USTC). Finally, this review discusses challenges and future research opportunities. We found that, owing to the latest computer hardware and AI technology, computational human body models are moving closer to real human anatomy structures for accurate radiation dose calculations.
진단 X선 촬영에 의한 소아 및 성인의 장기 등가선량과 유효선량을 구하는 방법론을 개발하였다. 연령에 따른 체격의 차이가 방사선량 분포에 미치는 영향을 평가하기 위해, 식도를 포함한 4개 연령군의 MIRD형 수학적 모의피폭체를 제작하였다. 두 가지의 전형적인 진단 X선 절차인 흉부 PA와 복부 AP 진단 X선 촬영을 모사하여, 연령별 선량을 계산하였다. 흉부 PA 진단 X선 촬영절차에 의해서 환자들은 대략 0.03mSv의 유효선량을 피폭하는 것으로 나타났다. 복부 AP 진단 X선 촬영절차의 경우 연령에 따라서 0.4에서 1.7mSv의 유효선량을 받는 것으로 나타났다. 한정된 조사장을 갖는 방사선에 대해서 선량을 평가했기 때문에, 장기의 위치와 크기, 모양, 그리고 방사선이 입사하는 표면으로부터의 필이 등이 선량 계산에 상당한 영향을 미쳤다. 따라서 진단 X선의 조사장이나 선질의 조절 등을 통해 방호의 최적화를 위한 노력이 중요한 것으로 나타났다. 본 연구에서 개발된 선량계측 절차는 의료방사선 방호의 최적화를 위한 수단으로 활용될 수 있다.
선량 증강 현상에서 발생하는 물리적 특성과 증강 물질과의 상호 작용으로부터 발생하는 이차입자 생성을 평가하였다. Geant 4, MIRD 두부 팬텀을 이용한 몬테카를로 전산 모사를 진행하였으며, 선형가속기에서 발생되는 4, 6, 10, 15, 18, 25 MV X선을 선원으로 적용하였다. 10, 20, 30 mg/g의 금(aurum), 가돌리늄(gadolinium) 증강 물질을 팬텀 내부 종양에 모사하였으며, 물리적 상호작용의 변화와 이차입자 발생에 따른 입자플루언스와 초기 에너지로부터 방사선가중인자를 고려하여 등가선량을 평가하였다. 방사선 선량 증강 물질에 의한 상호작용은 고 원자번호에서 기인하여 광전효과에 의한 에너지 흡수를 높이는 것으로 나타났으며, 10 MV 이상의 에너지에서는 광핵반응의 증가를 나타내었다. 이로 인해, 팬텀 내부에서 양성자, 중성자와 같은 이차입자 발생의 증가를 보였으며, 중성자에 의한 등가선량이 최대 424.2배 증가하는 것으로 나타났다. 본 연구는 선량 증강 현상에서의 에너지 전달, 흡수의 물리적 과정을 모사하여, 증강 현상에서 발생하는 물리적 특성을 분석하고자 하였다. 이러한 결과는 향후 in-vivo, in-vitro 선량 증강 실험을 위한 기초 자료로 활용될 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]