• Title/Summary/Keyword: Line harmonic

Search Result 474, Processing Time 0.029 seconds

The Performance Comparison of The Harmonic Generators using Nonlinear Transmission Lines (비선형 전송선로를 이용한 고조파 발생기 성능 비교)

  • Park, Soonwoo;Kim, Hongjoon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1212-1216
    • /
    • 2015
  • In this paper, we compared the performance of the Right Handed Nonlinear Transmission Line (RH-NLTL) and Left Handed Nonlinear Transmission Line (LH-NLTL) as a harmonic generator. For a performance comparison, we fabricated both a RH-NLTL and a LH-NLTL harmonic generator whose operational bandwidth is from 0.5 GHz to 1.5 GHz. Under the each condition for the RH-NLTL and the LH-NLTL to maximize second harmonic, the output power of the second harmonic was 9.33 dB lower than the input power for the RH-NLTL and 12.67 dB lower than the input power for the LH-NLTL. Under the each condition for the RH-NLTL and the LH-NLTL to maximize third harmonic, the output power of the third harmonic was 13.33 dB lower than the input power for the RH-NLTL and 14.83dB lower than the input power for the LH-NLTL. Also, we have observed that, generatlly, a RH-NLTL is useful in generating various multiple harmonics and a LH-NLTL is useful in generating a specific order of harmonic by adjusting a proper DC vias, input frequency and input power. These tendencies could be a good guideline to use NLTLs as a frequency multiplier.

ON F-HARMONIC MAPS AND CONVEX FUNCTIONS

  • Kang, Tae-Ho
    • East Asian mathematical journal
    • /
    • v.19 no.2
    • /
    • pp.165-171
    • /
    • 2003
  • We show that any F-harmonic map from a compact manifold M to N is necessarily constant if N possesses a strictly-convex function, and prove 'Liouville type theorems' for F-harmonic maps. Finally, when the target manifold is the real line, we get a result for F-subharmonic functions.

  • PDF

LINE SIDE HARMONIC ANALYSIS OF SINGLE-PHASE DIODE BRIDGE RECTIFIER WITH A DC FILTER CAPACITOR

  • Liu, Jinjun;Wang, Zhaoan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.603-608
    • /
    • 1998
  • Single-phase diode bridge rectifiers with dc filter capacitor usually operate in discontinuous mode and generate large amounts of harmonic currents. This paper presents a precise harmonic analysis of the line side current in the case that both the filter inductor and the filter capacitor are not infinite. The analytical expressions of the line side performance parameters associated with harmonics are derived. The curves that show the relationship of these parameters associated with harmonics are derived. The curves that show the relationship of these parameters as the functions of circuit parameters are illustrated. By simulation the results are verified to be accurate and the conclusion clearly reveals the relations between the line side performance parameters and circuit parameters.

  • PDF

EDGE VERSION OF HARMONIC INDEX AND HARMONIC POLYNOMIAL OF SOME CLASSES OF GRAPHS

  • NAZIR, RABIA;SARDAR, SHOAIB;ZAFAR, SOHAIL;ZAHID, ZOHAIB
    • Journal of applied mathematics & informatics
    • /
    • v.34 no.5_6
    • /
    • pp.479-486
    • /
    • 2016
  • In this paper we define the edge version of harmonic index and harmonic polynomial of a graph G. We computed explicit formulas for the edge version of harmonic index and harmonic polynomial of many well known classes of graphs.

Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM (6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF

Harmonic Analysis of 154KV System in Kwangyang Steel Works (제철소 154KV계통 고조파해석)

  • Kim, J.H.;Min, H.J.;Kang, Y.G.;Han, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.26-28
    • /
    • 2001
  • This paper discussed for harmonic analysis of 154kv system in Kwangyang steel works. The harmonic modelings are developed by harmonic measurement for scores of days in a 154kv substation at a same time. In this paper, the measurement values of harmonic are compared to the analysis results in incoming line. Case studies are presented to predict harmonic distortion of the future system.

  • PDF

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.

Line Current Characteristics of Multilevel H-Bridge Inverters: Part II - Harmonic Reduction with Multiple Transformer Windings (다단 H-브릿지 인버터의 입력전류특성(II) - 다중 변압기 결선에 의한 고조파 저감)

  • Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.237-245
    • /
    • 2008
  • Recently, multilevel H-bridge inverters have become popular in medium to high power ac drive applications. One of significant advantages of them is low harmonic contents in their input line currents thanks to the transformer with multiple phase-shifted secondary windings. This paper attempts to provide basic guidelines for the design of the phase shifting transformer windings and theoretical analysis of input line current harmonics of H-bridge inverters. The part II is devoted to the analysis of the harmonic characteristics of the input line current, providing mathematical background for the equidistant phase-shifting angle distribution policy for harmonic elimination.

Compact Multi-harmonic Suppression LTCC Bandpass Filter Using Parallel Short-Ended Coupled-Line Structure

  • Wang, Xu-Guang;Yun, Young;Kang, In-Ho
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.254-262
    • /
    • 2009
  • This paper presents a novel simple filter design method based on a parallel short-ended coupled-line structure with capacitive loading for size reduction and ultra-broad rejection of spurious passbands. In addition, the introduction of a cross-coupling capacitor into the miniaturized coupled-line can create a transmission zero at the second harmonic frequency for better frequency selectivity and attenuation level. The aperture compensation technique is also applied to achieve a strong coupling in the coupled-line section. The influence of using the connecting transmission line to cascade two identical one-stage filters is studied for the first time. Specifically, such a two-stage bandpass filter operating at 2.3 GHz with a fractional bandwidth of 10% was designed and realized with low-temperature co-fired ceramic technology for application in base stations that need high power handling capability. It achieved attenuation in excess of -40 dB up to $4f_0$ and low insertion loss of -1.2 dB with the size of 10 mm ${\times}$ 7 mm ${\times}$ 2.2 mm. The measured and simulated results showed good agreement.

AC harmonic elimination and reactive power compensation by voltage-type active filter (전압형 능동필터에 의한 교류고조파제거와 무효전력보상)

  • 김한성;최규하;신우석;이제필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.688-692
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter, composed of a three-phase voltage-type PWM inverter and the capacitor, compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, the several compensation characteristics. Also the experimental results are shown to verify the theory proposed in this paper.

  • PDF