• 제목/요약/키워드: Limiting circuit

검색결과 252건 처리시간 0.027초

모의송전계통에 차단기의 전류비율을 고려한 초전도 한류기 설치위치 분석 (Analysis on Installation Location of SFCL considering Current Rate of Circuit Breaker in a Power Transmission System)

  • 박한민;김진석;임성훈;김재철
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.357-364
    • /
    • 2015
  • The power system configuration is changed to solve increasing power demand. This changes in power system configuration with mesh-, network grid generate the problem of fault current increase. Superconducting fault current limiter (SFCL) has been expected the one of the solutions to solve this problem. And there has already been reported much to the application and research of SFCL in the power distribution system. However, the application and research of SFCL are insufficient in a transmission power system. Also, the fault current limiting effect by the SFCL varies with installation location of SFCL. Therefore, this paper constructed the power transmission system through experiment and analyzed installation location method of SFCL using the current rate of each circuit breaker (CB) according to fault location.

단상 AC Line 호환형 대용량 전원 장치 구현 방안 (Universal Single-Phase Line Compatible High Power AC/DC Converter)

  • 김병석;강경수;노정욱
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.297-304
    • /
    • 2015
  • A conventional single-phase high-power system typically generates a large AC line input current at universal 90 VAC condition. Sometimes, this phenomenon can block the Earth Leakage Circuit Breaker (ELCB), which causes problems. Replacing power facilities is essential to ensure smooth operations. Thus, this paper proposes a method that can drive higher power than the limit of conventional power facilities. The proposed method can reduce the large AC line input current by limiting the input power of Power Factor Correction (PFC). An additional battery circuit can supplement the power deficiency. Specifically, a bidirectional converter with charging and discharging functions was adopted for the battery circuit. Finally, the validity of the proposed system could be confirmed by modal analysis and simulation, and an experiment in 2 KW condition was implemented with a prototype sample as well.

코일의 직.병렬결합을 이용한 초전도 사고전류제한기의 동작전류 증가 (Increase of Operational Current in a SFCL using Series or Parallel Coupling of Coils)

  • 임성훈
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.46-51
    • /
    • 2007
  • 본 논문에서는 두 코일의 직 병렬결합을 이용한 초전도 사고전류제한기의 사고전류제한 특성을 분석하였다. 구조는 병렬 또는 직렬로 연결된 두 코일과 두 코일 중 하나와 직렬 또는 병렬로 연결되는 초전도 소자로 구성된다. 동작원리는 사고전에는 초전도 소자는 초전도 상태에 있어 병렬 또는 직렬로 연결된 두 코일에 의해 발생되는 자속은 서로 상쇄되어 두 코일에 유기되는 전압이 제로를 유지하게 되지만 사고가 발생할 경우 초전도 소자의 저항이 발생되어 두 코일에서 발생되는 자속은 더 이상 상쇄되지 않게 된다. 따라서 두 코일에 전압이 유기되고 이에 따라 사고전류를 제한하게 된다. 단락실험을 통해 두 코일의 직 병렬결합에 따른 사고전류제한 특성을 분석하였으며 분석을 동해 사고전류제한기의 동작전류를 증가시킬 수 있음을 확인하였다.

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

마이크로솔더링을 이용한 정전류다이오드 회로 자외선 LED 광원모듈 제작 (Fabrication Of Ultraviolet LED Light Source Module Of Current Limiting Diode Circuit By Using Flip Chip Micro Soldering)

  • 박종민;유순재;카완 안일
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.237-240
    • /
    • 2016
  • The improvement of irradiation intensity and irradiation uniformity is essential for large area and high power UVA light source application. In this study, large number of chips bonded by micro soldering technique were driven by low current, and current limiting diodes were configured to supply constant current to parallel circuits consisting of large number of series strings. The dimension of light source module circuit board was $350{\times}90mm^2$ and 16,650 numbers of 385 nm flip chip LEDs were used with a configuration of 90 parallel and 185 series strings. The space between LEDs in parallel and series strings were maintained at 1.9 mm and 1.0 mm distance, respectively. The size of the flip chip was $750{\times}750{\mu}m^2$ were used with contact pads of $260{\times}669{\mu}m^2$ size, and SAC (96.5 Sn/3.0 Ag/0.5 Cu) solder was used for flip chip bonding. The fabricated light source module with 7.5 m A supply current showed temperature rise of $66^{\circ}C$, whereas irradiation was measured to be $300mW/cm^2$. Inaddition, 0.23% variation of the constant current in each series string was demonstrated.

2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성 (Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit)

  • 조용선;박형민;남긍현;이나영;한태희;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF

자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석 (Analysis of fault Current Limiting Characteristics due to Ratio of Inductances between Coil 1 and coil 2 in a Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.856-862
    • /
    • 2005
  • A flux-lock type SFCL consists of two coils, which are wound in parallel each other through an iron core, and a HTSC thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance generated of the HTSC thin film, and thereby the fault current can be limited by the impedance of the flux-lock type SFCL. The amplitude of fault current can be set by the impedance of the flux-lock type SFCL. In this paper, we investigated the variance of the limiting current due to the ratio of inductances between coil 1 and coil 2 in the flux-lock type SFCL through the computer simulations and short circuit tests. In addition, both the simulation results and experimental ones were compared each other. From the comparison of both the results, the simulation results agreed well with the experimental ones.

Design of HTS power cable with fault current limiting function

  • Kim, Dongmin;Kim, Sungkyu;Cho, Jeonwook;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.7-11
    • /
    • 2020
  • As demand for electricity in urban areas increases, it is necessary to improve electric power stability by interconnecting neighboring substations and high temperature superconductor (HTS) power cables are considered as a promising option due to its large power capacity. However, the interconnection of substations reduces grid impedance and expected fault current is over 45 kA, which exceeds the capacity of a circuit breaker in Korean grid. To reduce the fault current below 45 kA, a HTS power cable having a fault current limiting (FCL) function is considered by as a feasible solution for the interconnection of substations. In this study, a FCL HTS power cable of 600 MVA/154 kV, transmission level class, is considered to reduce the fault current from 63 kA to less than 45 kA by generating an impedance over 1 Ωwhen the fault current is induced. For the thermal design of FCL HTS power cable, a parametric study is conducted to meet a required temperature limit and impedance by modifying the cable core from usual HTS power cables which are designed to bypass the fault current through cable former. The analysis results give a minimum cable length and an area of stainless steel former to suppress the temperature of cable below a design limit.

Operational Characteristics of a Flux-Lock Type SFCL Integrated with Voltage-Controlled Voltage Source Inverter

  • Lee, Su-Won;Lim, Sung-Hun;Ko, Sung-Hun;Lee, Seong-Ryong
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.546-551
    • /
    • 2008
  • In this paper, a flux-lock type superconducting fault current limiter(SFCL) integrated with a voltage-controlled voltage source inverter(VC-VSI) is proposed. The suggested equipment, which consists of a flux-lock type SFCL and a VCVSI, can perform the fault current limiting operation from the occurrence of a short-circuit. In addition, it can compensate the reactive power that the non-linear load requires and also perform the uninterruptible power supply(UPS) as well as the load voltage stabilization by controlling the amplitude and the phase of the inverter's output voltage. The specification for a test model was determined and its various functions such as the fault current limiting and the power conditioning operations were presented and analyzed via computer simulation. Through the analytical results based on the computer simulation, the validity of the analysis was confirmed and its multi-operation was discussed.

3상 일체화된 자속구속형 고온초전도 전류제한기의 동작특성 시뮬레이션 (Simulation of Operational Characteristics in Integrated Three-Phase Flux-Lock Type SFCL)

  • 임성훈;박충렬;한병성;박형민;조용선;최효상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.167-168
    • /
    • 2005
  • The operational characteristics of the integrated three-phase flux-lock type superconducting fault current limiter (SFCL) were analyzed. The suggested three-phase SFCL consisted of a three-phase flux-lock reactor and three high-Tc superconducting (HTSC) elements. The former has three windings wound on an iron core, each of which has the same turn's ratio between coil 1 and coil 2. The latter are connected in series with coil 2 of each phase. The integrated three-phase flux-lock type SFCL showed the operational characteristics that the fault phase could affect the sound phase, which resulted in quenching the HTSC element in the sound phase. Through the computer simulation applying numerical analysis for its three-phase equivalent circuit, the fault current limiting characteristics of the integrated three-phase flux-lock type SFCL according to the ground fault types were compared.

  • PDF