• 제목/요약/키워드: Lightning Impulse

검색결과 228건 처리시간 0.028초

심매설 접지전극의 전류인가위치에 따른 과도접지임피던스 특성 (Transient impedance characteristics according to the injection position of deep-driven ground rods)

  • 이복희;이봉;이수봉;이승주;전병욱;엄주홍;조성철;이태형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.297-300
    • /
    • 2008
  • This paper presents the behaviors of transient and conventional grounding impedances of a deep-driven ground rods associated with the injection point of lightning impulse currents. The transient impedance of deep-driven ground rods under lightning impulse currents were higher than the static ground resistance. The transient grounding impedances strongly depend on the injection point and size of grounding electrodes and the rising time of impulse current. Reduction of ground system inductance is an important factor to lightning surge protection.

  • PDF

14주기 열화에 따른 22.9kV 전력케이블의 Lightning-Impulse 특성분석 (Lightning Impulse Characteristics for 22.9kV Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;허종철;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2274-2276
    • /
    • 2005
  • Cyclic aging for 14days is performed to remove the large amount of the volatiles found in freshly manufactured cable. In this paper, we examined lightning impulse characteristics of power cable before and after cyclic aging for 14days. As the result, the breakdown voltage after aging was lower than that before aging, but the breakdown voltage after aging was higher than that before aging in TR CNCV-W $60mm^2$ power cable.

  • PDF

복합차체의 낙뢰에 대한 인체 안전성 분석 (Safety Analysis for Passengers of Composite Car-body against Lightning Strikes)

  • 김성욱;최수연;박대원;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.144-150
    • /
    • 2008
  • In this paper, the safety for passengers of composite car-body against lightning strikes was analyzed by the application of an impulse generator which can produce impulse current up to 50 [kA] with 8/20 [us] waveform. Potential difference on inside surface of the car-body was measured as a safety parameter for the passengers against lightning strikes. The potential difference between 20 [cm] distant was 175 [V] at 37.67 [kA], and it corresponded to 875 [V] between 1 [m] distant. The amount of charge flowing a passenger at 100 [kA] impulse current can be estimated to 0.31 [mA s]. This is much less than the limit amount of charge for human body, 30 [mA s] which is presented by Koeppen and Osypka.

  • PDF

낙뢰로 인한 전기화재의 현장조사기법 연구 (A Study on Investigation Method of the Electric Fire Scene Caused by Lightning)

  • 송재용;사승훈;남정우;김진표;박남규
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.50-56
    • /
    • 2011
  • 최근 지구온난화에 의한 영향으로 낙뢰의 발생빈도가 증가하는 추세이고, 낙뢰에 수반되는 뇌격전류의 강도 또한 강해지고 있는 추세이다. 2008년 기준 국내의 낙뢰 발생 빈도는 56만여 건 정도가 발생하였으며, 낙뢰로 인한 인명피해 사고 및 건축구조물의 피해는 나날이 증가하고 있다. 특히, 낙뢰로 인한 전기화재는 낙뢰 발생에 따른 대지전위 상승으로 접지선과 전원선간 절연파괴 과정에서 발생되며, 현장조사 결과, 낙뢰 발생 지역에 인접한 지역에서 동시다발적으로 전기적 피해가 발생하였다. 낙뢰에 대한 피해를 방지하기 위해서는 낙뢰 보호 장치의 설치 및 등전위 접지 시행 등의 방법이 요구된다. 또한 낙뢰로 인한 화재현장 조사에 있어서는 기상청에서 제공되는 낙뢰 발생 기록 및 화재현장과 인접한 지역에서 동시다발적인 전기적 특이점 형성 여부에 대한 검토가 필요하다.

Effective Impulse Impedances of Deeply Driven Grounding Electrodes

  • Lee, Bok-Hee;Jeong, Dong-Cheol;Lee, Su-Bong;Chang, Keun-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.207-214
    • /
    • 2004
  • This paper presents the characteristics of transient and effective impulse impedances for deeply driven grounding electrodes used in soil with high resistivity or in downtown areas. The laboratory test associated with the time domain performance of grounding piles subjected to a lightning stroke current has been carried out using an actual-sized model grounding system. The ground impedances of the deeply driven ground rods and grounding pile under impulse currents showed inductive characteristics, and the effective impulse ground impedance owing to the inductive component is higher than the power frequency ground impedance. Both power frequency ground impedance and effective impulse ground impedance decrease upon increasing the length of the model grounding electrodes. Furthermore, the effective impulse ground impedances of the deeply driven grounding electrodes are significantly amplified in impulse currents with a rapid rise time. The reduction of the power frequency ground impedance is decisive to improve the impulse impedance characteristics of grounding systems.

$8/20{\mu}s$ 임펄스전류의 크기와 인가횟수가 ZnO 바리스터의 수명에 미치는 영향 (Effects of injected number and amplitude of $8/20{\mu}s$ impulse current on the life of ZnO varistor)

  • 이복희;이봉;이수봉;강성만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.275-279
    • /
    • 2005
  • This paper presents leakage current characteristics as a function of injected number and magnitude of impulse current, when$8/20{\mu}s$ lightning impulse current is injected to ZnO varistor. The life of ZnO varistor against $8/20{\mu}s$ lightning impulse current was evaluated. The injected number of the test current to breakdown was inversely proportional to the amplitude of impulse current.

  • PDF

뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화 (Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test)

  • 이복희;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

한양대학교 1600kV/70kA 충격 전압/전류 시험설비 구축 (HY 1600kV/70kA Impulse Voltage/Current Test Facility)

  • 장용무;김철호;황률;이방욱;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.229-229
    • /
    • 2009
  • This Impulse Voltage and Current Test System is designed for performing of impulse voltage tests with Lightning impulse voltage 1.2/50(LI) up to 1520kV peak value and switching impulse voltages 250/2500(SI) up to 1120kV peak valu acc. to IEC 60060-1, and furthermore for impulse current test, e.g. testing of arrester sections($U_{res}$=95kV)with current impulses 4/10 and 8/20 up to 70kA peak value.

  • PDF

임펄스전압에 대한 N2가스의 절연파괴특성 (Electrical Breakdown Characteristics of N2 Gas under Impulse Voltages)

  • 신희경;김동규;이복희
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.131-136
    • /
    • 2011
  • This paper aims to examine the possibility of using an environmentally friendly $N_2$ as an alternative gas to $SF_6$. For this purpose, we have investigated breakdown characteristics of $N_2$ under impulse voltages in a quasi-uniform electric field gap. The 1.2/50[${\mu}s$] lightning impulse voltage, switching impulse voltages and oscillatory impulse voltages were applied at the test gap. The electric field utilization factor ranges from 0.5 to 0.8. The experimental data of $SF_6$ and $N_2$ acquired in the same experimental condition are presented in parallel for comparison. As a result, the breakdown voltages in $SF_6$ and $N_2$ are linearly increased with the gas pressure, also the breakdown voltages in $N_2$ are increased with increasing the gap distance and electric field utilization factor. The positive breakdown voltages are higher than the negative breakdown voltages. The nagative basic lightning impulse withstand level of 150[kV] in $N_2$ of about 0.5[MPa] is nearly equal to that in $SF_6$ of 0.15[MPa]. It is seen from the results obtained in this work that $N_2$ can be used as an eco-friendly alternative gas to $SF_6$ in distribution power equipment.

Discharge Characteristics in Soils Subjected to Lightning Impulse Voltages

  • Kim, Seung Min;Yoo, Yang-Woo;Lee, Bok-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.446-454
    • /
    • 2016
  • In this paper, we present experimental results of the soil discharge characteristics as a function of moisture content when a 1.2/50-㎲ lightning impulse voltage is applied. For this study, laboratory experiments were carried out based on factors affecting the transient behavior in soils. The electrical breakdown voltages in soils were measured for a 0-6% range of moisture content for sand and a 0 - 4% range of moisture content for gravel. A test cell with semi-spherical electrodes buried face-to-face in the middle of a cylindrical container was used. The distance separating the electrodes is 100 mm. As a result, the time-lag to breakdown in soils decreases as the amplitude of applied voltage increases. The time-lag to initiation of ionization streamer is decreased, with an increase in the moisture content. However, the formative time-lag is rarely changed. The behavior of soil discharges depend not only on the type of soil and its moisture content but also on the amplitude of the impulse voltage. When the test voltage is applied repeatedly, electrical breakdown occurs along different discrete paths, leading radially away from the injected electrode. i.e., the fact that the ionization streamers propagate in different paths from shot to shot was observed.