• Title/Summary/Keyword: Light fixture

Search Result 52, Processing Time 0.031 seconds

Hybrid infrared-visible multiview correlation to study damage in a woven composite complex-shaped specimen

  • Andrija Zaplatic;Zvonimir Tomicevic;Xuyang Chang;Ivica Skozrit;Stephane Roux;Francois Hild
    • Coupled systems mechanics
    • /
    • v.12 no.5
    • /
    • pp.445-459
    • /
    • 2023
  • In this study, a cyclic tensile test on a notched butterfly specimen made of woven glass fiber composite was performed on a modified Arcan fixture. During the mechanical test, the sample was monitored with a hybrid stereoscopic system comprised of two visible lights and one infrared camera. The visible light cameras were employed for kinematic measurements using a finite-element-based multiview correlation technique. A semi-hybrid correlation approach was followed, providing Lagrangian temperature fields of the Region of Interest. Due to the complex composite architecture and specimen shape, localized shearing was observed during the tensile loading. Furthermore, asymmetrical damage developed around the notches as revealed by localized strains and thermal hot spots.

A Study on the Light Weight Hand Lamp for Explosion-Proof Type (휴대형 방폭등의 경량화 연구)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • For lighting of dark and hazardous workplace such as compartment of ships under construction, workers should use hand lamps of explosion-proof type. However, the heavy weight of such lamps has prevented most impatient workers from using such types of lamps extensively. In this paper, we developed a light weight hand lamp of intrinsic safety type which reduced the weight a lot while maintaining or improving the lighting and explosion-proof function. We made a prototype which consisted of lamp fixture and high frequency power supply. Testing results show that the hand lamp meets well all the explosion-proof testing requirements of the Korea Occupational Safety and Health Agency. And more, we surveyed the explosion protection technology of a light weight hand lamp, and suggested the advantage/disadvantage to apply lighting of hand lamp about economical aspect.

Structural Stability Study of C/GFRP Composite material Traffic Light Fixture and Wind Load (인발 성형법을 이용한 C/GFRP 복합소재 신호등 부착대의 구조적 안정성에 관한 연구)

  • Na, Kyoung-Su;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.11
    • /
    • pp.9-16
    • /
    • 2021
  • As the climate changes rapidly due to warming, it is becoming very important to ensure the stability of environmental structures. It is necessary to choose a material that withstands repeated external forces (wind loads) and satisfies members and joints that have energy absorbing power. Even if the strength of the traffic light attachment is sufficient, if the rigidity is insufficient, there is a limit to the displacement during strong winds. Excessive deformation may cause damage and fall, resulting in a safety accident. The author intends to study mechanical properties and resistance to external environment as a structural material capable of withstanding wind load (50m/sec) by fabricating a C/GFRP composite traffic light attachment using the pultrusion method (Pultrusion).

Investigation of osseointegration according to the healing time after having iatrogenic mobility of implant fixtures (임플란트 고정체의 인위적 비틀림 후 시간 경과에 따른 골재유착 반응에 관한 연구)

  • Hwang, Yun-Jin;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.308-314
    • /
    • 2010
  • Purpose: The purpose of this study is to analyze the change in re-osseointegration over time and bone reaction at the interface between implant fixture and the surface of the bone, after destroying re-osseointegration by distorting the bone-implant interface artificially. Materials and methods: Experimental implant fixtures (cp titanium, ${\phi}3.75\;mm{\times}4\;mm$) which didn't have surface treatment were produced. Two or three fixtures were implanted on both tibias of twelve female rabbits (New Zealand white, more than 3.5 kg). Then after six weeks, removal torque (RT) was measured and the results were recorded as the first measurement values. The fixtures were submerged again to get reosseointegration between the bone and fixture. To identify the change in re-osseointegration of submerged fixtures over time, six groups had the healing time for four days (group I), one week (group II), two weeks (group III), three weeks (group IV), four weeks (group V) and five weeks (group VI), and then the secondary removal torque was measured for each group. To identify the bone formation under fluorescent light, tetracycline (15 mg/kg, IM) were treated on the rabbits of each group. After the second measurement, the rabbits were sacrificed, and 16 slides were made, two or three for each group. The slides were observed under the fluorescent light with light microscope. To find out the change in the secondary removal torque over the primary removal torque in progress of time, the averages of the increase rate of the primary and secondary torque removal force were calculated. Then, to find out if there were any critical differences between the primary removal torque and the secondary removal torque in each group and among the groups, the results were analyzed statistically by paired t- test, one-way ANOVA, and Duncan's Multiple Range Test. Results: In group I and II, secondary removal torque decreased, especially in group I. In group III, IV, V, and VI, secondary removal torque increased critically. Comparing the differences among the groups, the critical difference was shown between group I, II and group III, IV, V, VI. Mineralization at the interface between the bone and implant fixture was identified from the first week, and bone formation was shown more clearly from the second week. Conclusion: If the implant fixture remains unforced for a certain period of time after the fixture has had iatrogenic mobility, re-osseointegration occurs at the surface of the fixture, and for tibias of rabbits, higher re-osseointegration was obtained within two weeks.

Development and Performance Property Investigation of Lighting System using Plastic Optical Fiber (플라스틱 광섬유를 이용한 조명시스템 개발과 특성 분석)

  • Shin, Sang-Uk;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.25-32
    • /
    • 2010
  • Compared to general lighting method, the lighting system that uses optic fiber can provide only the visible light of good quality to subject by eliminating ultraviolet ray and infrared ray. Thanks to this merit, it is possible to prevent the hard phenomenon of subject caused by ultraviolet ray and infrared ray and to provide the agreeable light environment. This study developed indoors illumination system of high color rendering on the basis of plastic optic fiber with excellent optical property and processing to substitute halogen lamp which has been used for excellent color rendering in spite of low efficiency and short life. Producing pilot product of the designed illumination system and evaluating the property of electric and optical property, ultraviolet ray radiation quantity and temperature property, this study verified the excellence of suggested lighting system of plastic optic fiber.

A Study on Interior Design of Kwacheon House (과천주택 실내공간 디자인)

  • Kim, Sung-Hye;Choi, Young-Mi
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2007.11a
    • /
    • pp.214-215
    • /
    • 2007
  • This project was designed to create a warmth space for Kwacheon House. To create warmth space, four factors - Natural Habitat, Timeless Comfort, Exotic Exuberance, Luxe Living - were hired to design concepts. At first, the walls were remained to support structure and to keep privacy and others were removed to draw in light to the inner space. Light is the main element to have variation and natural space. Ornaments that were motived by nature, were accepted in moulding, furniture and fixture to enhance the comfort. At last, classical lightings added up to harmonize between day and night.

  • PDF

Trend of the National and International Standards for LED Lightings (차세대 LED 조명의 국내외 표준화 동향)

  • Cho, M.R.;Jeon, S.K.;Yang, S.Y.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.141-144
    • /
    • 2009
  • LED Lightings market remains highly fragmented, encompassing many niche applications. Architectural lighting is the largest and many applications are for colored (R, G, B) light. Hundreds of companies worldwide are participating at the luminaire or fixture level. Standard setting is on a fast track. The larger LED lightings market scale, the more important standardization of performance evaluation techniques to clearly prescribe the product specification.

  • PDF

FINITE ELEMENT EVALUATION OF THE EFFECT OF DIFFERENCES IN THE ABUTMENT AND THE FIXTURE DIAMETERS ON THE CERVICAL BONE STRESSES ($XiVE^{(R)}$ 임플랜트 시스템에서 고정체보다 작은 직경의 지대주 장착이 경부 피질골 응력에 미치는 효과에 대한 유한요소해석적 연구)

  • Yu Won-Jae;Lee Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.95-104
    • /
    • 2005
  • Statement of problem. Higher stresses at the cervical bone around dental implants have been seen as a primary cause of the bone resorption at the site. Purpose : To determine the possibility of stress reduction by assembly of different abutment and implant in diameters. Material and methods. Abutments of several different diameters assembled on the top of XiVE$^{(R)}$ implants were axisymmetrically modeled for a series of finite element analyses. Abutments of 3.4, 3.8, 4.5, and 5.5 mm diameters were assumed to be sit on implants of the same or bigger diameters. All the abutments with an exception of 3.4mm dia, are technically possible to be assembled on bigger implants. Main consideration was given to the stresses at the cervical cortical bone induced by loads of parallel to the implant axis. Results and conclusions. 1. Higher stresses were observed at the cervical area of all the models of the same diameters of abutment and future. The peak stresses, which were shown to be a function of the fixture diameter, were from 1-1.85MPa. 2. Difference in the diameters of the abutments and the implants actually reduced the cervical bone stresses. 3. Downsizing of the abutment by one step resulted in 0.1MPa (5%) reduction of the stresses. In light of the relatively lower bone stress, however, this amount of stress reduction was decided to be biomechanically insignificant.

All goods Inspection Convergence System for the Development of LCD Molybdenum Pin (LCD 몰리브덴 핀 개발을 위한 전수검사 융합시스템)

  • Lee, Jeongl-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.183-187
    • /
    • 2020
  • The molybdenum cup and molybdenum pin, which are the main materials of the molybdenum electrode used for the LCD BLU CCFL electrode, have not been developed in Japan and all of them are imported and used from Japan, is giving a competitive burden. In this research, to develop the manufacturing technology of molybdenum pin used for CCFL electrode of LCD BLU, development of linear processing technology, development of molybdenum wire surface treatment technology, development of wire cutting technology, production of molybdenum pin, design and fabrication of JIG and Fixture for inspection, molybdenum pin prototyping and analysis, and development of 100% molybdenum pin inspection technology. In this paper, especially, In this paper, especially, research on the convergency design for total inspection machine is treated. is treated.

A Mobile Object Tracking Scheme by Wired/wireless Integrated Street Lights with RFID

  • Cha, Mang Kyu;Kim, Jung Ok;Lee, Won Hee;Yu, Ki Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.25-35
    • /
    • 2016
  • Since a sophisticated location determination technology (LDT) is necessary for accurate positioning in urban area environments, numerous studies related to the LDT using the RFID (Radio Frequency IDentification) technology have been implemented for real-time positioning and data transferring. However, there are still lots of unsolved questions especially regarding what to use as base stations and what are corresponding results under the intrinsic complexity of alignment and configuration of components used for the RFID positioning. This study proposes the street light fixtures as base stations where the RFID receivers will be embedded for the mobile tracking scheme. As street light fixtures are usually installed at a certain distance interval, they can be used as base stations for the RFID receiver installation. Using the principle of the single row triangle network, the RFID receiver organization is determined based on the experiments such as recognition distance measurement and tag position accuracy estimation at inside and outside of the single row triangle network. The results verify that the mobile tracking scheme which uses RFID-embedded street light fixtures, suggested and configured in this study, is effective for the real-time outdoor positioning.