• Title/Summary/Keyword: Leakage Measurement

Search Result 501, Processing Time 0.022 seconds

Linearity Enhancement of RF Power Amplifier Using Digital Predistortion with Tanh as a Nonlinear Indexing Function (비선형 인덱싱 함수 Tanh로 구현한 디지털 전치 왜곡을 이용한 RF 전력증폭기의 선형성 향상)

  • Seong, Yeon-Jung;Cho, Choon-Sik;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.430-439
    • /
    • 2011
  • In this paper, we design a digital predistortion(DPD) for linearity enhancement of RF power amplifier operating in 900 MHz band. We verify improvement of linearity by comparing the proposed DPD using tanh as a nonlinear indexing function and the DPD using linear indexing function based on signal amplitude. The digital predistortion is realized by look-up table(LUT) method, and the Saleh model is employed for power amplifier modeling, then a commercial power amplifier module is used for measurement. The LUT has 256 tables, and the NLMS(Normalized Least Mean Square) algorithm was utilized for an adaptive algorithm for estimation. As a result, we improve the ACLR(Adjacent Channel Leakage Ratio) by around 15 dB.

DESIGN OPTIMIZATION OF RADIATION SHIELDING STRUCTURE FOR LEAD SLOWING-DOWN SPECTROMETER SYSTEM

  • KIM, JEONG DONG;AHN, SANGJOON;LEE, YONG DEOK;PARK, CHANG JE
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.380-387
    • /
    • 2015
  • A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as $^{235}U$, $^{239}Pu$, $^{241}Pu$, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux ($>10^{12}n/cm^2{\cdot}s$) neutron source comprised of a high-energy (30 MeV)/high-current (~2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (< $0.06{\mu}Sv/h$), a few shielding materials [high-density polyethylene (HDPE)eBorax, $B_4C$, and $Li_2CO_3$] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HDPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HDPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near future.

The Degradation Analysis of Characteristic Parameters by NBTI stress in p-MOS Transistor for High Speed (고속용 p-MOS 트랜지스터에서 NBTI 스트레스에 의한 특성 인자의 열화 분석)

  • Lee, Yong-Jae;Lee, Jong-Hyung;Han, Dae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1A
    • /
    • pp.80-86
    • /
    • 2010
  • This work has been measured and analyzed the device degradation of NBTI (Negative Bias Temperature Instability) stress induced the increase of gate-induced-drain-leakage(GIDL) current for p-MOS transistors of gate channel length 0.13 [${\mu}m$]. From the relation between the variation of threshold voltage and subthreshold slop by NBTI stress, it has been found that the dominant mechanism for device degradation is the interface state generation. From the GIDL measurement results, we confined that the EHP generation in interface state due to NBTI stress led to the increase of GIDL current. As a results, one should take care of the increased GIDL current after NBTI stress in the ultra-thin gate oxide device. Also, the simultaneous consideration of reliability characteristics and dc device performance is highly necessary in the stress parameters of nanoscale CMOS communication circuit design.

System and method for detecting gas using smart-phone (스마트폰을 이용한 가스검출시스템 및 검출 방법연구)

  • Bang, Yong-Ki;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.129-137
    • /
    • 2015
  • This study is in regard to the gas detection system and gas detection method utilizing smart phone. This study includes; 1) the sensor module attached to the smart phone to detect and measure flammable gas or toxic gas; and 2) gas detection APP which is installed inside the smart phone and recognizes the user information and location information automatically by reading RFID tag indicating the user or the location to detect gas through the contact area where RFID and blue tooth reader is installed inside of the above mentioned smart phone, and then measures the combustible gas or toxic gas by operating above mentioned sensor module and obtains the data thus measured, and above mentioned smart phone is characterized by its transmission of the above mentioned user information, location information and measured data which are obtained by above mentioned gas detecting APP to operation server via communication network. With this, reliability for the location detecting gas by the user, the result of the measurement, etc. can be secured. Furthermore, this provides the effect of preventing artificial manipulation at the time of input which is associated with the identification of the user to be measured by utilizing removable sensor module and application or the mistake resulted from wrong input by the user. In addition, by transmitting the measured data from the sensor module carrying out gas detection to operation server, this provides the effect of making it possible to process the data thus collected to a specialized data for combustible gas or toxic gas.

Reviews and Proposals of Low-Voltage DRAM Circuit Design (저전압 DRAM 회로 설계 검토 및 제안)

  • Kim, Yeong-Hui;Kim, Gwang-Hyeon;Park, Hong-Jun;Wi, Jae-Gyeong;Choe, Jin-Hyeok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.4
    • /
    • pp.251-265
    • /
    • 2001
  • As the device scaling proceeds, the operating voltage(VDD) of giga-bit DRAMs is expected to be reduced to 1.5V or down, fir improving the device reliability and reducing the power dissipation. Therefore the low-voltage circuit design techniques are required to implement giga-bit DRAMs. In this work, state-of-art low-voltage DRAM circuit techniques are reviewed, and four kinds of low-voltage circuit design techniques are newly proposed for giga-bit DRAMs. Measurement results of test chips and SPICE simulation results are presented for the newly proposed circuit design techniques, which include a hierarchical negative-voltage word-line driver with reduced subthreshold leakage current, a two-phase VBB(Back-Bias Voltage) generator, a two-phase VPP(Boosted Voltage) generator and a bandgap reference voltage generator.

  • PDF

Measurement and Analysis of Temperature Dependence for Current-Voltage Characteristics of Homogeneous Emitter and Selective Emitter Crystalline Silicon Solar Cells (Homogeneous 에미터와 Selective 에미터 결정질 실리콘 태양전지의 온도에 따른 전류-전압 특성 변화 측정 및 분석)

  • Nam, Yoon Chung;Park, Hyomin;Lee, Ji Eun;Kim, Soo Min;Kim, Young Do;Park, Sungeun;Kang, Yoonmook;Lee, Hae-Seok;Kim, Donghwan
    • Korean Journal of Materials Research
    • /
    • v.24 no.7
    • /
    • pp.375-380
    • /
    • 2014
  • Solar cells exhibit different power outputs in different climates. In this study, the temperature dependence of open-circuit voltage(V-oc), short-circuit current(I-sc), fill factor(FF) and the efficiency of screen-printed single-crystal silicon solar cells were studied. One group was fabricated with homogeneously-doped emitters and another group was fabricated with selectively-doped emitters. While varying the temperature (25, 40, 60 and $80^{\circ}C$), the current-voltage characteristics of the cells were measured and the leakage currents extracted from the current-voltage curve. As the temperature increased, both the homogeneously-doped and selectively-doped emitters showed a slight increase in I-sc and a rapid degradation of V-oc. The FF and efficiency also decreased as temperature increased in both groups. The temperature coefficient for each factor was calculated. From the current-voltage curve, we found that the main cause of V-oc degradation was an increase in the intrinsic carrier concentration. The temperature coefficients of the two groups were compared, leading to the idea that structural effects could also affect the temperature dependence of current-voltage characteristics.

On-line Measurement and Control of Plant Growth I. Development of $\textrm{CO}_2$ Control Algorithm (작물의 생장정보 계측 및 생육제어에 관한 연구 I. 탄산가스 제어 알고리즘 개발)

  • 진제용;류관희;홍순호
    • Journal of Bio-Environment Control
    • /
    • v.2 no.1
    • /
    • pp.27-36
    • /
    • 1993
  • Carbon dioxide enrichment for greenhouse crops has generally been a standard commercial practice for many years. Vegetable crops such as tomato, cucumber, and lettuce respond positively to the $CO_2$ enrichment. But improper $CO_2$ enrichment leads to physiological damage and economical loss. This study was carried out to develop a $CO_2$ concentration control algorithm considering growth stage and efficiency. The measurand was $CO_2$ consumption rate and top fresh weight that represents growth stage. The weight of top fresh lettuce as a whole in the tray was measured through a non-destructive method. The demand in $CO_2$ concentration according to growth stage was investigated. The results are summarized as follows. 1. The $CO_2$ consumption rate could be measured within the error of $\pm$ 15.4mg$CO_2$/hr in the range of $CO_2$ concentration of 500-1500ppm. 2. The weight of top fresh lettuce could be measured within the error $\pm$ 4.3g in the range of 0-1400g. 3. The $CO_2$ control model developed could determine an economical $CO_2$ supply rate considering $CO_2$ consumption rate and leakage rate. 4. The $CO_2$ control algorithm based on the control model was composed of feedforward control for maintaining a stable $CO_2$ concentration level, and feedback control with $CO_2$ consumption rate and top fresh weight for adapting to the change in $CO_2$ demand by growth stage. 5. For the performance test with the developed control algorithm on lettuce the decrease in $CO_2$ supply rate was obtained without a significant decrease in top fresh weight.

  • PDF

A Study on Optical Current Sensor and Voltage Sensor for automation of power distribution (배전자동화 개폐기 내장형 광 전류 및 광 전압 센서에 관한 연구)

  • 양승국;오상기;박해수;김인수;김요희;홍창희
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.1
    • /
    • pp.89-98
    • /
    • 2002
  • Optical current sensor and optical voltage sensor modules were designed and fabricated to improve measurement error and insulation in automatic power distributor By using Faraday effect, optical current sensor with an $\alpha$-iron core was designed and fabricated to minimize current induction of the other phase and was optimized to maintain linearity. Optical voltage sensor was fabricated owing to the pockets effect and adopted spatial electric field type because of small room in an automatic power distributor. To connect a distributor with an external terminal for signal processing, optical multi connector was designed, fabricated and tested for coupling loss and gas leakage. The linearity of optical current sensor for applied current maintains variation of smaller than 2.5% for applied current range from 20A to 700A. The linearity of optical voltage sensor was smaller than 1% for appling voltage from 6.6kV to 19.8kV. Since the measured characteristics are good, these devices can be considered as being applicable in practice.

Effect of New Herbicides(CGA 82725 & DOWCO 453) on Membrane Permeability in Bean Leaf Tissue (새로운 제초제(除草劑)가 강남콩잎의 세포막(細胞膜) 투과성(透過性)에 미치는 영향(影響))

  • Kim, Jae-Cheol
    • Korean Journal of Weed Science
    • /
    • v.5 no.1
    • /
    • pp.85-88
    • /
    • 1985
  • Leakage of electrolytes from leaf discs of treated bean (Phaseolus velgaris L.) plant was the criterion used to investigate the effect of four herbicides on the permeability of leaf-cell membrane. CGA 82725 (2-propynyl 2-((3, 5-dichloro-2 pyridinyl) oxy) phenoxy prpanate) at $10^{-3}M$ increased significantly cell membrane permeability within 1 h after 12 h treatment. Significant increase in cell membrane permeability was also detected at $10^{-2}M$ of DOWCO 453 (Haloxy-methyl 2-(4 (3-chloro- 5-(trifuluoromethyl)-2-pyridinyl) phenoxy) propanate. The effect of dinoseb (2-(1-methylpropyl)-4, 6-dintrophenol) on cell premeability was detected at $10^{-4}M$ after 12h. The highest conductivity measurement was obtained from paraquat (1, 1'- dimethyl-4, 4'-bipyridinium ion). Increase in cell membrane permeability was not always associated with injury symptoms such as appearance of necrotic area in leaves.

  • PDF

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.