• 제목/요약/키워드: L-series

검색결과 1,443건 처리시간 0.029초

Ability of Lactobacillus GR-1 and RC-14 to Stimulate Host Defences and Reduce Gut Translocation and Infectivity of Salmonella typhimurium

  • Reid, Gregor;Charbonneau, Duane;Erb, Julie;Poehner, Russ;Gonzalez, Silvia;Gardiner, Gillian;Bruce, Andrew W.
    • Preventive Nutrition and Food Science
    • /
    • 제7권2호
    • /
    • pp.168-173
    • /
    • 2002
  • Gastrointestinal infections kill over two million people each year, and pathogen contamination of livestock causes many cases of food poisoning. Two candidate intestinal probiotic strains, L. rhamnosus GR-1 and L. fermentum RC-14 were found to inhibit the growth of Salmonella typhi, Shigella dysenteriae, E. coli O157:H7, Listeria monocytogenes, L. innocua, Enterococcus faecalis, and Bacteroides fragilis. In a series of mouse experiments, L. rhamosus GR-1 and L rhamnosus GG protected against S. typhimurium infection and translocation to the liver and spleen, reduced mortality and induced intestinal phagocytic and immunoglobulin responses. In a second series of experiments, the combination of L. rhamnosus GR-1 and L. fermentum RC-14 was superior to L. rhamnosus GG and placebo in protecting the mice from the lethal effect of salmonella. In summary, the use of combinations of probiotic lactobacilli as dietary supplements or foods could be considered for people at high risk of salmonella intestinal infection. Given the post-infection complications that can arise, such natural methods warrant further exploration especially given the increasing problem of antibiotic resistance and the lack of alternative measures available to many developing countries.

조선시대 복식에 나타난 자색계 색명의 개념적 의미 (Conceptual Meaning of Purple-series Color Names in the Clothing of Joseon Dynasty Period)

  • 김순영;남윤자;조우현
    • 한국의류학회지
    • /
    • 제28권11호
    • /
    • pp.1458-1469
    • /
    • 2004
  • In this study, color names focusing on the purple series, appearing in the clothing of the Joseon Dynasty, were classified systematically, and the conceptual meaning of each name were investigated through various methods. The results are as follows; First, the color names of purple-series were classified systematically. According to the integration scheme of morphemes, color names could be divided into two categories; single names and composite names. Color names could also be classified into universal and limited names according to the areal distribution of literatures. Secondly, the conceptual meaning of the color names of purple-series were considered. The conceptual meaning could be divided into two categories; one 'etymological and dyeing methodological meaning', the other 'color systematic meaning' By studying the dictionary definition of color names, comparing and analyzing the material composition of colors, the etymological and dyeing methodological meaning could be grasped. Furthermore, the color systematic meaning of each name could be grasped through the cluster analysis of L*, a*, b* values measured from the relics of clothing. Thirdly, the conceptual semantic structure were established on the basis of conceptual meanings of purple-series color names. The conceptual semantic structure of purple-series color names is forming discrete structure with the dyeing method and material of dyes as their semantic components.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

LH-모멘트에 의한 극치홍수량의 빈도분석을 위한 적정분포형 유도 (Derivation of Optimal Distribution for the Frequency Analysis of Extreme Flood using LH-Moments)

  • 맹승진;이순혁
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.229-232
    • /
    • 2002
  • This study was conducted to estimate the design flood by the determination of best fitting order of LH-moments of the annual maximum series at six and nine watersheds in Korea and Australia, respectively. Adequacy for flood flow data was confirmed by the tests of independence, homogeneity, and outliers. Gumbel (GUM), Generalized Extreme Value (GEV), Generalized Pareto (GPA), and Generalized Logistic (GLO) distributions were applied to get the best fitting frequency distribution for flood flow data. Theoretical bases of L, L1, L2, L3 and L4-moments were derived to estimate the parameters of 4 distributions. L, L1, L2, L3 and L4-moment ratio diagrams (LH-moments ratio diagram) were developed in this study.

  • PDF

LH-모멘트의 적정 차수 결정에 의한 설계홍수량 추정 ( I ) (Estimation of Design Flood by the Determination of Best Fitting Order of LH-Moments ( I ))

  • 맹승진;이순혁
    • 한국농공학회지
    • /
    • 제44권6호
    • /
    • pp.49-60
    • /
    • 2002
  • This study was conducted to estimate the design flood by the determination of best fitting order of LH-moments of the annual maximum series at six and nine watersheds in Korea and Australia, respectively. Adequacy for flood flow data was confirmed by the tests of independence, homogeneity, and outliers. Gumbel (GUM), Generalized Extreme Value (GEV), Generalized Pareto (GPA), and Generalized Logistic (GLO) distributions were applied to get the best fitting frequency distribution for flood flow data. Theoretical bases of L, L1, L2, L3 and L4-moments were derived to estimate the parameters of 4 distributions. L, L1, L2, L3 and L4-moment ratio diagrams (LH-moments ratio diagram) were developed in this study. GEV distribution for the flood flow data of the applied watersheds was confirmed as the best one among others by the LH-moments ratio diagram and Kolmogorov-Smirnov test. Best fitting order of LH-moments will be derived by the confidence analysis of estimated design flood in the second report of this study.

Weibull -3 및 Wakeby 분포의 L-모멘크법에 의한 설계갈수량 비교분석 (Comparative Analysis of Design Drought Flow by L-Moment in the Weibull-3 and Wakeby distributions)

  • 이순혁;박종화;맹승진;류경식;지호근
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.531-536
    • /
    • 1999
  • This study was carried out to derive optimal design drought flows by the Weibull-3 and Wakeby distributions for the annual drought flows series at seven watersheds along Han, Nagdong, Geum, Yeongsan and Seomjin river systems. L-coefficient of variation , L-skewness and L-kurtosis were calculated by the L-moment ratio respectivley. Parameters were estimated by the Methods o fL-Moments with continuous duration. Design drought flows obtained by Methods of L-Moments using Weibull plotting positions formula in the Weibull-3 and Wakeby distributions were compared by the Relative Mean Errors(RME), Relative Absolute Errors (RAE) and Root Mean Square Errors(RMSE). It has shown that design drought flows by the Wakeby distribution using method of L-moments are much closer to those of the observed data in comparison with those obtained by the Weibull-3 distribution using method of L-moments.

  • PDF

순차식 게이트 구동방식에 의한 직렬 공진형 고주파 인버터 특성 해석 (Analysis of Series Resonant High Frequency Inverter using Sequential Gate Control Strategy)

  • 배영호;서기영;권순걸;이현우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권3호
    • /
    • pp.57-66
    • /
    • 1993
  • 본 연구에서는 순차식 게이트구동방식을 사용하여 L, C 공진회로로 링크된 2조의 full-bridge 인버터회로를 병렬제어하는 기법을 제안하고 있다.MOSFET로 구성된 각 인버터는 한 개의 등가스위치 모델로 되어 직렬공진형 등가 half-bridge 인버터회로를 구성하고 있다. 게이트 제어기법으로 각 소자의 구동 주기를 분할 제어함으로서 소자의 직병렬 운전이 가능한 순차식 게이트 구동방식을 사용하고 이에 따른 인버터의 회로동작 모드를 분석하고 해석하였다.시뮬레이션을 통한 회로 해석 결과 각 인버터단과 소자의 전압 및 전류분담이 적절히 이루어지고 있음을 알 수 있었고 안정된 회로동작이 이루어지고 있음을 확인하였다.

  • PDF

직렬 복합 트랜지스터를 이용한 저전압 가변 트랜스컨덕터의 설계 (Design of Low Voltage Linear Tunable Transconductors using the Series Composite Transistor)

  • 윤창훈;유영규;최석우
    • 전자공학회논문지SC
    • /
    • 제38권5호
    • /
    • pp.52-58
    • /
    • 2001
  • 본 논문에서는 직렬 복합 트랜지스터를 이용한 저전압 선형 가변 트랜스컨덕터를 설계하였다. 직렬 복합트랜지스터는 포화 영역에서 동작하는 트랜지스터와 선형 영역에서 동작하는 트랜지스터가 직렬 연결된 구조로 낮은 공급 전압에서도 넓은 입력 전압 범위를 갖는다. 설계된 트랜스컨덕터는 $0.25{\mu}m$ CMOS n-well 공정 파라미터를 이용하여 HSPICE로 시뮬레이션한 결과 차단주파수는 309MHz 이고, 입력 신호 주파수가 10MHz일 때 1.5VP-P의 차동 입력에 대해 1.1%이하의 THD 특성을 갖는다.

  • PDF

역타공법 적용을 위한 콘크리트 경시변화 특성 연구 (A Study of Elapsed Time Change on Concrete for Top-Down Method)

  • 정근호;이종균;박선길;이영도;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.487-492
    • /
    • 1999
  • The purpose of this study to find the mixture of concrete for Top-Down method. Throughout test of elapsed time change and L-type flow, it was proposed basic performance and level of top-down method concrete. When change as to elapsed time is considered, so series of F10 added 10% S.P satisfied slump and demanded flow (60$\pm$5cm), and L-type slump, L-type flow satisfied liquidity, it can be considered basic mixture of designed actual frame later.

  • PDF