• 제목/요약/키워드: Ion-Selective Electrode

검색결과 184건 처리시간 0.021초

Alverine의 정량을 위한 Ion-Selective Electrodes (Ion-Selective Electrodes for the Determination of Alverine)

  • 이은엽;김기묘;김성진;허문희;안문규
    • 분석과학
    • /
    • 제8권1호
    • /
    • pp.79-84
    • /
    • 1995
  • Alverine에 대한 anionic counter ion으로서 acid red 97의 이용 가능성을 살펴보았다. PVC와 가소제의 비율이 같을 때 적절한 감응과 긴 수명을 나타내었으며, 검량선은 $1.0{\times}10^{-5}M$까지 직선성이었고 그 감응 기울기는 55.35mV/dec., 변동계수는 0.61이었다. Methylephedrine에 대하여는 -2.626, histidine에 대하여는 -2.216등의 선택계수를 보였고 pH 7.0~4.0에서 안정된 전위값을 얻을 수 있었다. $10^{-4}M$ 이하에서 20~30초 이내, 그 이상의 농도에서는 약 10초 이내에서 안정된 전위값을 얻을 수 있었다.

  • PDF

Comparative Study of Holmium (III) Selective Sensors Based on Thiacalixarene and Calixarene Derivatives as an Ionophore

  • Singh, Sanjay;Rani, Geeta
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2229-2237
    • /
    • 2012
  • The two chelates based on calix[4]arene and thiacalix[4]arene have been synthesized and used as neutral ionophores for preparing PVC based membrane sensor selective to $Ho^{3+}$ ion. The addition of potassium tetrakis(4-chlorophenyl)borate (KTpClPB) and various plasticizers, viz., NDPE, o-NPOE, DOP, TEP and DOS have been found to improve significantly the performance of the sensors. The best performance was obtained with the sensor no. 6 having membrane of $L_2$ with composition (w/w) ionophore (2%): KTpClPB (4%): PVC (37%): NDPE (57%). This sensor exhibits Nernatian response with slope $21.10{\pm}0.3mV/decade$ of activity in the concentration range $3.0{\times}10^{-8}-1.0{\times}10^{-2}M\;Ho^{3+}\;ion$, with a detection limit of $1.0{\times}10^{-8}M$. The proposed sensor performs satisfactorily over a wide pH range of 2.8-10, with a fast response time (5 s). The sensor was also found to work successfully in partially non-aqueous media up to 25% (v/v) content of methanol, ethanol and acetonitrile, and can be used for a period of 4 months without any significant drift in potential. The electrode was also used for the determination of $Ho^{3+}$ ions in synthetic mixtures of different ions and the determination of the arsenate ion in different water samples.

전위차법 효소 바이오센서를 이용한 식품의 구연산 정량분석 (Quantitative Analysis of Citrate in Foods Using a Potentiometric Enzyme Biosensor)

  • 권지영;김미라
    • 한국식품과학회지
    • /
    • 제38권2호
    • /
    • pp.169-175
    • /
    • 2006
  • Citrate Iyase(CL)와 oxaloacetate decarboxylase(OD)를 고정화하여 효소 반응기를 제작하고 효소반응으로 생성된 carbonate ion을 ion selective electrode를 이용한 전위차법 FIA system으로 식품에함유된 구연산의 농도를 측정하였다. 최적 센서 시스템의 조건은 CL과 OD을 같이 고정화시키는 방법으로 CL과 OD의 양이 각각 10 units, 60 units, 담체량은 0.3 g, carrier buffer 1(0.1 MTris buffer)은 pH 7.5, carrier buffer의 유속은 12 mL/hr으로 결정되었다. 최적 상태에서의 표준검량곡선은 $10^{-1}\;M-10^{-3}\;M$ 범위에서 직선적인 상관관계$(r^2=0.9986)$를 나타내었다. 당류와 유기산류에 대한 센서 시스템에 대한 방해효과를 측정한 결과 당류는 거의 저해효과를 보이지 않았으며 유기산의 경우도 저해 효과가 5% 미만으로 이들 물질에 의해 감응도가 크게 방해받지 않은 것으로 나타났다. 구연산 바이오센서와 GC를 사용하여 식품 시료에 함유된 구연산의 농도를 분석한 결과 두 방법간에 유의적인 차이가 없는 것으로 나타나 본 연구에서 구축한 구연산 바이오센서 시스템은 식품에 함유된 구연산 분석시 신뢰성 있는 결과를 주는 것으로 보여졌다.

Potentimetric Biosensor for Detection of L-Malate and D-Isocitrate Employing ${CO_{3}}^2-$ -Selective Electrode and Enzyme Immobilization in Flow Injection Analysis

  • Kwun, In-Sook;Kim, Meera
    • Preventive Nutrition and Food Science
    • /
    • 제3권1호
    • /
    • pp.36-42
    • /
    • 1998
  • Ion-selective eleltrodes(ISEs) are simple electrodechemical devices for the direct measurement of ions in the samples. A novel potentiometric biosensor for the determination of L-Malate or D-isocitrate has been developed by using CO2-3 -ISE-FIA system was composed of a pump, an injector, a malic enzyme or isocitric dehydrogenase enzyme reactor, a CO2-3 -ISE, a pH/mV meter, and an integrater. The various factors, such as buffer capacity types of plstericizer and polymer, were optimized for the CO2-3 selectivity. In this novel CO2-3 --ISE-FIA system, the potential difference due to the amount of CO2-3 produced from each enzyme reaction was proportional to the amount of L-malate or D-isocitrate.

  • PDF

Potentiometric Sensor for the Determination of Dibucaine in Pharmaceutical Preparations and Electrochemical Study of the Drug with BSA

  • Ensafi, Ali A.;Allafchian, A.R.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2722-2726
    • /
    • 2011
  • Plasticized poly(vinyl chloride), PVCs, with different membrane compositions tested for use in the construction of an ion-selective sensor for the determination dibucaine. A prepared membrane with dioctyl phthalate-PVC and ion-pair of N-(1-naphthyl)ethylenediamine dihydrochloride-tetraphenyl borate had a good potential to acts as a potentiometric sensor for the analysis of dibucaine. A linear relationship was obtained between potential and logC varying between $1.0{\times}10^{-6}$ and $1.0{\times}10^{-2}$ M dibucaine with a good repeatability and reproducibility. The sensor was applied for the determination of the drug in pharmaceuticals and biological fluids such as plasma and urine samples with satisfactory results. The drug electrode has also been used to study the interaction of bovine serum albumin (BSA) with dibucaine. The saturated quantities of dibucaine binding were 13.04, 5.30 and 9.70 mol/mol in 0.01, 0.02 and 0.1% of protein, respectively.

이온교환체로서 금속 -페난드롤린 -메페남산 3원 작물을 이용한 메페남산의 정량 (Determination of Mefenamic acid with ISEs Using Ternary Complex of Metal -phenanthroline -mefenamate as Ion-exchanger)

  • 허문회;김대병;남수자;문현숙;이미나;정문모;안문규
    • 약학회지
    • /
    • 제45권1호
    • /
    • pp.29-33
    • /
    • 2001
  • A method for the determination of anionic drug, mefenamate with ion-selective electrode using Fe(II)-1,10-phenanthroline chelate as a counter ion was developed. Benzyl nitrophenyl ether (BNPE) plasticized membrane was more selective and sensitive than the other tested membranes. This membrane electrode exhibits a linear response for 10$^{-2}$ M~5 $\times$ 10$^{-5}$ M of mefenamic acid with a slope of -61.4 mV/dec. in borate buffer solutions (pH 9.0). Potentiometric selectivity measurements revealed negligible interferences from various organic and ionorganic anions. Direct potentiometry and potentiometric titration method of mefenamic acid in capsule preparations are presented and compared.

  • PDF

액체막형 구리이온 선택성 전극의 제작과 전위차적정에의 응용 (Preparation of a Liquid Membrance Type Ion-Selective Electrode and Its Application to the Potentiometric Titration)

  • 이흥낙;양승태
    • 대한화학회지
    • /
    • 제29권2호
    • /
    • pp.137-143
    • /
    • 1985
  • 액체막형 구리이온 선택성 전극의 제작과 전위차적정에의 응용을 연구하였다. 액체 이온교환막은 수용액속의 Cu(II)을 1-(2-pyridylazo)-2-naphthol/nitrobenzene 용액 속으로 추출하여 만들었다. 액체 이온교환막 위에 HAc-NaAc 용액으로 완충된 $1.00 {\times} 10^{-3}M\;Cu(NO_3)_2$ 용액을 채우고 Ag/AgCl 내부 기준전극을 담그었다. 이 이온선택성 전극은 $1.00 {\times} 10^{-6}$ ~ $1.00 {\times} 10^{-3}$M Cu(II) 농도 범위에서 nerstian response를 보여주었다. 가장 적절한 이온교환체의 농도는 $1.00 {\times} 10^{-4}$M이었다. 여러가지 금속이온에 대한 이온선택성 전극의 선택계수를 측정하였다. EDTA를 적정제로 하여 Cu(II)에 대한 전위차적정에 응용하였다.

  • PDF