DOI QR코드

DOI QR Code

Chromium(III)-selective Electrode Using p-(4-Acetanilidazo)calix[4]arene as an Ionophore in PVC Matrix

  • Kumar, Pankaj (Department of Chemistry, Hindustan College of Science and Technology) ;
  • Shim, Yoon-Bo (Department of Chemistry and Center for Innovative Bio-Physio Sensor Technology, Pusan National University)
  • Published : 2008.12.20

Abstract

Keywords

References

  1. National Research Council Recommended Dietary Allowance, 10th ed.; National Academy Press: Washington DC, 1989.
  2. Kimbrough, D. E.; Cohen, Y.; Winer, A. M.; Creelman, L.; Mabuni, C. A. Crit. Rev. Environ. Sci. Technol. 1999, 29, 1. https://doi.org/10.1080/10643389991259164
  3. Sharma, R. K.; Goel, A. Anal. Chim. Acta 2005, 534, 137. https://doi.org/10.1016/j.aca.2004.11.026
  4. Gholivand, M. B.; Raheedayat, F. Electroanal. 2004, 16, 1330. https://doi.org/10.1002/elan.200302956
  5. Singh, A. K.; Panwar, A.; Singh, R.; Baniwal, S. A. Anal. Bioanal. Chem. 2002, 372, 506. https://doi.org/10.1007/s00216-001-1134-5
  6. Khalil, S.; Wassel, A. A.; Belal, F. F. Talanta 2004, 63, 303. https://doi.org/10.1016/j.talanta.2003.10.046
  7. Singh, A. K.; Panwar, A.; Kumar, S.; Baniwal, S. Analyst 1999, 124, 521. https://doi.org/10.1039/a901162e
  8. Abbaspour, A.; Izadyar, A. Talanta 2001, 53, 1009. https://doi.org/10.1016/S0039-9140(00)00593-2
  9. Gholivand, M. B.; Sharifpour, F. Talanta 2003, 60, 707. https://doi.org/10.1016/S0039-9140(03)00130-9
  10. Gupta, V. K.; Jain, A. K.; Kumar, P.; Agarwal, S.; Maheshwari, G. Sens. & Act. B: Chem. 2006, 113, 182. https://doi.org/10.1016/j.snb.2005.02.046
  11. Singh, A. K.; Gupta, V. K.; Gupta, B. Anal. Chim. Acta 2007, 585, 171. https://doi.org/10.1016/j.aca.2006.11.074
  12. Kwon, N.-H.; Lee, K.-S.; Won, M.-S.; Shim, Y.-B. Analyst 2007, 132, 906. https://doi.org/10.1039/b706905g
  13. Hyun, M. H.; Piao, M.-H.; Cho, Y. J.; Shim, Y.-B. Electroanal. 2004, 16, 1785. https://doi.org/10.1002/elan.200303027
  14. Rahman, Md. A.; Won, M. S.; Shim, Y.-B. Anal. Chem. 2003, 75, 1123. https://doi.org/10.1021/ac0262917
  15. Gutsche, C. D. Calixarenes; The Royal Society of Chemistry: Cambridge, 1991.
  16. Diamond, D.; Nolan, K. Anal. Chem. 2001, 73, 22A.
  17. Bakker, E.; Qin, Y. Anal. Chem. 2006, 78, 3965. https://doi.org/10.1021/ac060637m
  18. Talanova, G. G.; Elkarim, N. S. A.; Talanov, V. S.; Bartsch, R. A. Anal. Chem. 1999, 71, 3106. https://doi.org/10.1021/ac990205u
  19. Cadogan, F.; Kane, P.; Mckervey, M. A.; Diamond, D. Anal. Chem. 1999, 71, 5544. https://doi.org/10.1021/ac990303f
  20. Kaifer, M. G.; Reddy, P. A.; Gutsche, G. D.; Echegoyen, L. J. Am. Chem. Soc. 1997, 119, 5222. https://doi.org/10.1021/ja963601s
  21. Deligoz, H.; Ercan, N. Tetrahedron 2002, 58, 2881. https://doi.org/10.1016/S0040-4020(02)00156-4
  22. Craggs, A.; Moody, G. J.; Thomas, J. D. R. J. Chem. Educ. 1974, 51, 541. https://doi.org/10.1021/ed051p541
  23. Ammanmm, D.; Pretsch, E.; Simon, W.; Lindler, E.; Bezegh, A.; Pungor, E. Anal. Chim. Acta 1985, 171, 119. https://doi.org/10.1016/S0003-2670(00)84189-6
  24. Bakker, E.; Buhlmann, P.; Pretsch, E. Chem. Rev. 1997, 97, 3083. https://doi.org/10.1021/cr940394a
  25. Ankere, P.; Wieland, E.; Ammann, D.; Dohner, R. E.; Asper, R.; Simon, W. Anal. Chem. 1981, 53, 1970. https://doi.org/10.1021/ac00236a005
  26. Gadzekpo, V. P. Y.; Christian, G. D. Anal. Chim. Acta 1984, 164, 279. https://doi.org/10.1016/S0003-2670(00)85640-8
  27. Pettine, M.; Campanella, L.; Millero, F. J. Environ. Sci. Technol. 2002, 36, 901.

Cited by

  1. Electrochemical Analysis of Some Toxic Metals by Ion–Selective Electrodes vol.41, pp.4, 2011, https://doi.org/10.1080/10408347.2011.589773
  2. Molecule and ion recognition of nano-baskets of calixarenes since 2005 vol.64, pp.5, 2011, https://doi.org/10.1080/00958972.2011.555538
  3. Analytical applications of calixarenes from 2005 up-to-date vol.69, pp.1-2, 2011, https://doi.org/10.1007/s10847-010-9848-7
  4. Development of Chromium(III) Selective Potentiometric Sensor by Using Synthesized Triazole Derivative as an Ionophore vol.2013, pp.2090-9071, 2013, https://doi.org/10.1155/2013/142752
  5. Preparation and analytical application of new Cr3+-selective membrane electrodes based on acylhydrazone-containing benzimidazole derivatives vol.13, pp.3, 2016, https://doi.org/10.1007/s13738-015-0749-y
  6. Chromium(III) Potentiometric Sensor Based on Para-Tertiary-Butyl Calix[4]arene vol.23, pp.10, 2011, https://doi.org/10.1002/elan.201100220
  7. Cu (II), Zn (II) Complexes Containing Calix [4] Arene Modified by Salicylaldehyde Acylhydrazone - Synthesis, Properties and Application vol.455-456, pp.1662-8985, 2012, https://doi.org/10.4028/www.scientific.net/AMR.455-456.1244
  8. -pyrazol-3-yl)phenol vol.26, pp.10, 2014, https://doi.org/10.1002/elan.201400163
  9. Determination of chromium (III) ions in water samples by UV–vis spectrometry based on benzyl-functionalized benzimidazolylidene ligand pp.1607-0798, 2018, https://doi.org/10.2166/ws.2018.032
  10. Potentiometric Membrane Electrode for Cr(III) Ion Based on a New Aryl Amide Bifunctional Bridging Ligand as a Neutral Carrier vol.56, pp.4, 2008, https://doi.org/10.1002/jccs.200900101
  11. Application of Potentiometric Sensors in Real Samples vol.51, pp.3, 2021, https://doi.org/10.1080/10408347.2019.1711013