• 제목/요약/키워드: Internal fluids

검색결과 243건 처리시간 0.022초

Diagnostic Tools of Pleural Effusion

  • Na, Moon Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제76권5호
    • /
    • pp.199-210
    • /
    • 2014
  • Pleural effusion is not a rare disease in Korea. The diagnosis of pleural effusion is very difficult, even though the patients often complain of typical symptoms indicating of pleural diseases. Pleural effusion is characterized by the pleural cavity filled with transudative or exudative pleural fluids, and it is developed by various etiologies. The presence of pleural effusion can be confirmed by radiological studies including simple chest radiography, ultrasonography, or computed tomography. Identifying the causes of pleural effusions by pleural fluid analysis is essential for proper treatments. This review article provides information on the diagnostic approaches of pleural effusions and further suggested ways to confirm their various etiologies, by using the most recent journals for references.

다단계 부분 구조법에 의한 비 압축성 유동 계산 (An Incompressible Flow Computation using a Multi-level Substructuring Method)

  • 김진환
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.83-90
    • /
    • 2004
  • Substructuring methods are usually used in finite element structural analyses. In this study a multi-level substructuring algorithm is developed and proposed as a possible candidate for incompressible fluid solves. Finite element formulation for incompressible flow has been stabilized by a modified residual procedure proposed by Ilinca et.al.[5]. The present algorithm consists of four stages such as a gathering stage, a condensing stage, a solving stage and a scattering stage. At each level, a predetermined number of elements are gathered and condensed to form an element of higher level. At highest level, each subdomain consists of only one super-element. Thus, the inversion process of a stiffness matrix associated with internal degrees of freedom of each subdomain has been replaced by a sequential static condensation. The global algebraic system arising feom the assembly of each subdomains is solved using Conjugate Gradient Squared(CGS) method. In this case, pre-conditioning techniques usually accompanied by iterative solvers are not needed.

  • PDF

S-duct 내부유동의 출구경계조건 및 난류모텔의 영향검토 (Effects of Outflow Boundary Conditons and Turbulent Models on an S-duct Flow)

  • 홍승규;이광섭
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.120-126
    • /
    • 2000
  • An S-duct flow is subjected to an entrance flow of Mach 0.6. The duct turns $30^{\circ}$ and reverses its turn by $30^{\circ}$ followed by a straight section. Such an internal flow induces a secondary flow due to curvature effect. Goal of this paper is to show the sensitivity of outflow boundary conditions on the quality of numerical solutions as well as to show curvature effect on the flow field. The often-used Baldwin-Lomax turbulence model is shown to be less functional on the concave region when the secondary flow has its strong Influence.

  • PDF

로터-스테이터 상호작용을 고려한 3차원 유동 해석 (3-D Incompressible Viscous Flow Analysis Around A Rotor-Stator with Rotor-Stator Interaction)

  • 김경한;정영래;박원규;이상욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.78-83
    • /
    • 2000
  • An iterative time marching procedure for solving incompressible internal flow has been applied to the flow around a rotor-stator. This procedure solves three-dimensional incompressible Reynolds-averaged Navier-Stokes equation on a moving, time-deforming, non-orthogonal body-fitted grid using second-order accurate schemes for the time derivatives and third/second-order accurate schemes for the spatial derivatives. To handle rotationg geometry, the multiblock technique is applied and the overall flow domain is subdivided into two blocks. In each block, a grid is generated and flowfield is solved independently of the other blocks. The boundary data for each block is provided by the neighboring blocks using bilinear interpolation technique.

  • PDF

LES를 이용한 열린 공동 유동과 공동 내 물질 확산의 수치적 모사 (LARGE EDDY SIMULATION OF FLOW AND MASS EXCHANGE PROCESSES BETWEEN A CHANNEL AND AN OPEN CAVITY)

  • 장경식;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.239-243
    • /
    • 2005
  • Fully three-dimensional Large Eddy Simulation calculations of the flow past 2D cavity are conducted to study the purging of neutrally buoyant or dense miscible contaminants introduced instantaneously inside the cavity. The length to depth ratio(L/D) is 2 and Reynolds number based on the depth is 3,360. Fully developed turbulent inflow are fed at the inlet from precursor simulation of channel flow. Mean flow pattern and unsteady features are investigated based on the experimental data of Pereira and Sousa. From the study of mass exchange processes, it is found that the mechanism of removal of the contaminant is very different between the non-buoyant and buoyant cases. In the buoyant case, internal wave motion which interacts with a strong cavity vortex is dominant in the ejection mechanism of the contaminants.

  • PDF

Cavity 형상비에 따른 혼합 중대 효과의 수치적 연구 (NUMERICAL STUDY OF MIXING ENHANCEMENT EFFECT DUE TO THE CONFIGURATION RATIO OF CAVITY)

  • 오주영;배영우;김기수;변영환;이재우
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.245-248
    • /
    • 2005
  • SCRamjet is the key technology for hypersonic flight over mach number 6. It is characterized by very short residence time in combustor because its internal flow is supersonic. In this short time, the whole process of combustion must be done. Especially numerical study of combustor is important because air-fuel mixing rate influences the performance of combustor. Various methods of air-fuel mixing enhancement are proposed. Among these, cavity injection method is selected to study in this paper. The numerical study is conducted with the variation of the cavity length at the fixed height of unit and jet injection on the downstream of cavity.

  • PDF

화염배출 출구면적 변화에 대한 수직발사관 내부 초음속 충돌유동의 수치적 해석 (NUMERICAL INVESTIGATIONS OF SUPERSONIC JET IMPINGEMENT ON A FLAT WALL IN A CONFINED PLENUM)

  • 이광섭;홍승규;안창수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.281-285
    • /
    • 2005
  • Viscous solutions of supersonic jet impinging on a flat wall in a confined plenum are simulated using three-dimensional Navier-Stokes solver. A confined plenum was designed for simulating the missile launch and analyzing the behavior of the exhaust plume, which were accompanied by complex flow interactions with shock and boundary layer. Concerns of this paper are to show accurate simulation of internal flow in confined plenum and to demonstrate the jet flow structure when the jet interacts with a small opening on the side. Objectives of this numerical simulation are to understand the effect of changing the plume exit area of the plenum. Pressure and temperature rise at certain position in the plenum are traced and compared with test data.

  • PDF

대장암에서 장세척물의 세포학적 소견 (Cytologic Findings of Colon Lavage Fluid in Colon Cancer)

  • 이혜경;주명진;이광민;정동규;최용우
    • 대한세포병리학회지
    • /
    • 제7권1호
    • /
    • pp.103-106
    • /
    • 1996
  • Although exfoliative colonic cytology for the diagnosis of colorectal cancer has been largely abandoned due to the widespread use of colonoscopy, some authors still insiston the usefulness of colon lavage fluid. We tried evaluating the diagnostic feasibility of colon lavage fluid cytology using an orally administered balanced electrolyte solution. We collected colon lavage fluids in 106 patients prior to colonoscopy and reviewed the slides. Cytologic examination revealed neoplastic cells in 7 of 16(44%) cases of endoscopically proven adenocarcinoma patients. Therefore, we thin cytologic study of colon lavage fluid may be considered as one of the noninvasive diagnostic tools in colorectal cancer.

  • PDF

Paradoxical Transtentorial Herniation Caused by Lumbar Puncture after Decompressive Craniectomy

  • Jung, Heyun-Jin;Kim, Dong-Min;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권2호
    • /
    • pp.102-104
    • /
    • 2012
  • Although decompressive craniectomy is an effective treatment for various situations of increased intracranial pressure, it may be accompanied by several complications. Paradoxical herniation is known as a rare complication of lumbar puncture in patients with decompressive craniectomy. A 38-year-old man underwent decompressive craniectomy for severe brain swelling. He remained neurologically stable for five weeks, but then showed mental deterioration right after a lumbar puncture which was performed to rule out meningitis. A brain computed tomographic scan revealed a marked midline shift. The patient responded to the Trendelenburg position and intravenous fluids, and he achieved full neurologic recovery after successive cranioplasty. The authors discuss the possible mechanism of this rare case with a review of the literature.

희박기체영역에서의 직접모사법에 의한 축대칭 형상 주위의 유동장 해석에 관한 연구 (Studies on Flowfields Around Axisymmetric Bodies in the Rarefied Gas Regime Using the Direct Simulation Monte Carlo Method)

  • 이동대;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 추계 학술대회논문집
    • /
    • pp.71-77
    • /
    • 1998
  • In this study we calculated the flowfields around the axisymmetric bodies in the rarefied gas regime by using the DSMC. A flat-ended cylinder was selected as a representative axisymmetric body and the gas used for all calculations was nitrogen. With zero angle of attack, an increasingly rapid rise in density and the effect of shock waves near the flat-ended face were examined. And on the cylinder surface velocity slips and boundary layers could be observed in the results. Larsen-Borgnakke model was used for the energy redistribution in inelastic collisions. And by considering all internal energy modes, the distributions of translational, rotational and vibrational temperatures were plotted. The calculations were peformed for various Knudsen numbers, Especially the rotational temperatures calculated for a case were compared with the experimental results. And the simulation results show good agreements with the experimental ones.

  • PDF