• Title/Summary/Keyword: Intensity limit

Search Result 360, Processing Time 0.026 seconds

Implications of bi-directional interaction on seismic fragilities of structures

  • Pramanik, Debdulal;Banerjee, Abhik Kumar;Roy, Rana
    • Coupled systems mechanics
    • /
    • v.5 no.2
    • /
    • pp.101-126
    • /
    • 2016
  • Seismic structural fragility constitutes an important step for performance based seismic design. Lateral load-resisting structural members are often analyzed under one component base excitation, while the effect of bi-directional shaking is accounted per simplified rules. Fragility curves are constructed herein under real bi-directional excitation by a simple extension of the conventional Incremental Dynamic Analysis (IDA) under uni-directional shaking. Simple SODF systems, parametrically adjusted to different periods, are examined under a set of near-fault and far-fault excitations. Consideration of bi-directional interaction appears important for stiff systems. Further, the study indicates that the peak ground accelertaion, velocity and displacement (PGA, PGV and PGD) of accelerogram are relatively stable and efficient intensity measures for short, medium and long period systems respectively. '30%' combination rule seems to reasonably predict the fragility under bi-directional shaking at least for first mode dominated systems dealt herein up to a limit state of damage control.

Spectrofluorimetric determination of free cyanide ion with fluorescent safranine-O (형광시약 Safranine-O를 이용한 유리 시안화 이온의 분광형광법 정량)

  • Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.159-163
    • /
    • 2012
  • A spectrofluorimetric method has been developed for the determination of free $CN^-$ in real samples with fluorescent safranine-O. When safranine-O interacts electrostatistically with $CN^-$, the fluorescent intensity of safranine-O is decreased. Several experimental conditions such as pH of the sample solution and the amount of safranine-O were optimized. $Ag^+$ interfered higher than any other ions. Interference of $Ag^+$ could be disregarded because $Ag^+$ was scarcely contained or mostly complexed with $CN^-$ in selected real samples. With this proposed method, the linear range of $CN^-$ was from 5.0 to 110 ng/mL and the detection limit of $CN^-$ was 2.9 ng/mL. For validating this technique, real samples (Cu, Ag, Au electroplating wastewater, and untreated wastewater in university and in sewage treatment plant) were used. Recovery yields of 91.5%~106.0% were obtained. Based on experimental results, it is proposed that this technique can be applied to the practical determination of free $CN^-$.

Quantitation of Antigen-Antibody Reaction Condition for Development of Fluorescence Image-based CD4 Rapid Test (형광 영상 기반 CD4 신속 검사법 개발을 위한 항원-항체 반응 조건 정량화)

  • Kim, Subin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.35-42
    • /
    • 2015
  • CD4+ T-cell count determines the effectiveness for antiretroviral therapy (ART) in patients with human immunodeficiency virus (HIV). Although ART slows the progression of HIV to AIDS, rapid counting of CD4+ T lymphocytes with a drop of patient's blood sample is urgently needed to ensure timely ART treatment in rural areas. Recently point-of-care CD4 testing devices have been developed by using non-flow based imaging cytometer incorporated with a sample cartridge where CD4+ T cells are reacted with fluorescently tagged specific antibodies. Here we conducted an experimental study using a conventional fluorescence microscope-based imaging system to quantitate the interaction of CD4 antibodies with CD4+ T cells at different reaction conditions. We demonstrated that a fast and affordable point-of-care CD4 test is feasible with a far less amount of antibodies and a shorter incubation time compared with a conventional sample preparation protocol for flow cytometry. We also proposed a general method to evaluate and compare the detection limit across different CD4 counting platforms by using fluorescently labelled microbeads for intensity calibration.

Automatic Focusing Vision System for Inspection of Size and Shape of Small Hole (소형(1mm이하) hole의 형태 및 크기 측정을 위한 자동초점 비젼검사기)

  • Han, Moon-Yong;Han, Hern-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.80-86
    • /
    • 1999
  • Since the quality of the coated wires is in various applications dependant on the coating depth, accuracy of hole size of dies used for coating wires must be maintained precisely, in general within one micron. This paper proposes a new vision system which measures automatically the size and shape of small holes having diameters less than 1mm within an error limit of 1 micron. To quickly obtain the focused image, this paper proposes an estimation method of the camera position using only a couple of defocused hole images. It measures the distributions of light intensity around the image boundary and decides the direction and distance of a camera motion. The proposed system measures the size, shape distortion, inclination of the hole against the axis of the dies structure, to decides the acceptability of the dies for use. The proposed algorithm has been implemented using a cheap 640${\times}$480 image system and has shown an average size error of 1micron when measuring the dieses having 0.1mm to 1.0mm diameters. It can be applied to the inspection of the size and position of holes in PCB, too.

  • PDF

Photonic Crystal Effect of Nano-Patterned PEDOT:PSS Layer and Its Application to Absorption Enhancement of ZnPc Thin Films

  • Han, Ji-Young;Ryu, Il-Whan;Park, Da-Som;Kwon, Hye-Min;Yim, Sang-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.252-252
    • /
    • 2012
  • It is widely accepted that short exciton diffusion lengths of organic semiconductors with respect to the film thickness limit the charge (hole and electron) separation before excitons recombination in organic photovoltaic (OPV) cells. Therefore the efficient absorption of incident light within the thin active organic layer is of great importance to improve the power conversion efficiency (PCE) of the cells. In this work, we fabricated 2-dimensionally (2D) nano-patterned poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOST:PSS) layers using capillary phenomenon and nano-imprinting technology at the scale of several hundred nanometers. This 2D nano-patterned PEDOT:PSS layer exerted photonic crystal effect such as redirection of light paths and variation of light intensity at specified wavelengths. It is also expected that the consequently alternated light pass lengths and intensities change the absorption properties of zinc phthalocyanine (ZnPc) thin films grown on top of the nano-patterned PEDOT:PSS layer. The influence of conductivity and thickness of the PEDOT:PSS layer on the absorption properties of ZnPc thin films were also investigated.

  • PDF

Spectrofluorimetric Determination of n-Octanol Based on its Ternary Complex with $Eu^{3+}$ and TTA ($Eu^{3+}$, TTA, 그리고 n-Octanol의 삼성분착물에 의한 n-Octanol의 분광형광분석법에 관한 연구)

  • Cha, Ki-Won;Park, Kwang-Won
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.433-438
    • /
    • 1997
  • The enhancing effect of n-octanol on the fluorescence intensity of the $Eu^{3+}$-thenoyltrifluoroacetone(TTA) system in the presence of Triton X-100 was studied using spectrofluorometric method. This complex exhibited very intense $Eu^{3+}$ ion fluorescence at 619nm, when optically excited at 345nm. Optimum conditions for the determination of n-octanol have also been investigated. The calibration graph was linear over the range $1{\times}10^{-5}M{\sim}1{\times}10^{-7}M$ and the detection limit for n-octanol is $1{\times}10^{-9}M$. The result obtained in the analysis of the synthetic sample agreed with the known value in the error range and the relative standard deviation was ca. 3.5%.

  • PDF

Analysis of Relations between Ice Accretion Shapes and Ambient Conditions by Employing Self-Organization Maps and Analysis of Variance (자가조직도와 분산분석을 활용한 결빙 형상과 외기 조건의 관계 분석)

  • Son, Chan-Kyu;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.8
    • /
    • pp.689-701
    • /
    • 2011
  • The relations between ambient conditions and ice accretion shapes are quantitatively analyzed by employing self-organization maps and analysis of variance. Liquid water contents(LWC), mean volumetric droplet diameter(MVD), ambient temperature and free-stream velocity are chosen as ambient conditions which change ice accretion shapes. The parameters of ice accretion shape are selected as maximum thickness, icing limits, ice heading, and ice accretion area. Qualitative analysis was conducted by employing self-organization maps which show the qualitative relations between ice shapes and ambient conditions. The quantitative results of analysis of variance yield intensity of ambient conditions to the parameters of ice accretion shapes.

Review on Delayed Hydride Cracking and Stress Corrosion Cracking of Metals (합금속의 수소취성과 응력부식균열 고찰)

  • Kim, Young Suk;Cheong, Yong Moo;Im, Kyung Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.4
    • /
    • pp.266-273
    • /
    • 2004
  • The objective of this study is an understanding of stress corrosion cracking of metals that is recognized to mostly limit the lifetime of the structural materials by comparing the features of delayed hydride cracking of zirconium alloys with those of stress corrosion cracking (SCC) of Ni-based alloys and hydrogen cracking of stainless steels. To this end, we investigated a dependence of delayed hydride cracking (DHC) velocity on the applied stress intensity factor and yield strength, and correlated a temperature dependence of the striation spacing and the DHC velocity. We reviewed a similarity of the features between the DHC of zirconium alloys, the SCC of Ni-based alloys and turbine rotor steels, and the hydrogen cracking of stainless steels and discussed the SCC phenomenon in metals with our DHC mode.

A Simple Benzimidazole Based Fluorescent Sensor for Ratiometric Recognition of Zn2+ in Water

  • Zhong, Keli;Cai, Mingjun;Hou, Shuhua;Bian, Yanjiang;Tang, Lijun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.489-493
    • /
    • 2014
  • A phenylbenzimidazole derivatized sensor (L) that behaves as a ratiometric fluorescent receptor for $Zn^{2+}$ in water has been described. In HEPES buffer at pH 7.4, sensor L displays a weak fluorescence emission band at 367 nm. Upon addition of $Zn^{2+}$, the emission intensity at 367 nm is decreased, concomitantly, a new emission band centered at 426 nm is developed, thus facilitates a ratiometric $Zn^{2+}$ sensing behavior. Sensor L binds $Zn^{2+}$ through a 1:1 binding stoichiometry with high selectivity over other metal cations. Sensor L displays a linear response to $Zn^{2+}$ concentration from 0 to $6.0{\times}10^{-5}M$, sensor L also exhibits high sensitivity to $Zn^{2+}$ with a detection limit of $3.31{\times}10^{-7}M$.

Development of Bioluminescence Immunoassay Using Photoprotein, Aequorin and Site-directed Immobilization

  • Shim, Yu-Nee;Rhee, In-sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.70-74
    • /
    • 2003
  • The heterogeneous bioluminescence immunoassay for digoxin was developed using photoprotein, native aequorin as a label and the site-directed immobilization technique based on avidin/biotin interaction. Aequorin is a bioluminescence protein, originally isolated from the jellyfish Aequoria Victoria and an attractive label in analytical applications because of sensitive detection due to virtually no background bioluminescent signal. Digoxin is a cardioactive drug, and its therapeutic level in serum is at low concentration with very narrow therapeutic index. The aequorin-digoxigenin conjugates were synthesized by the N-hydroxysuccinimide ester method and characterized in terms of bioluminescent residual activity. The resulting dose-response curve shows that the detection limit is $1.0\;{\times}\;10^{-10}\;M$ and a dynamic range is three orders of magnitude, which was obtained by $1.0\;{times}\;10^{-10}\;M$ conjugate and 0.9 μg/mL anti-digoxin antibody. Three structurally similar molecules to digoxin were examined for their cross-reactivity. None of these three compounds showed any crossreactivity with digoxin antibody employed in this study. Standard amounts of digoxin corresponding to the therapeutic range were spiked into the each serum solution. Study of the serum matrix effect indicated that correlation coefficient shows good agreement between luminescence light intensity between in buffer and in serum.