• Title/Summary/Keyword: Integrated operating program

Search Result 73, Processing Time 0.031 seconds

Implement of Integration Compression Environment Using Medical Images

  • Chu, Eun-Hyoung;Park, Mu-Hun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.268-272
    • /
    • 2003
  • Large medical images in PACS are compressed for saving storage space and improving network speed. The integrated compression environment was designed and developed for uniting of various compression methods. Various compression algorithm-RLE compression, lossless JEPG, JPEG, was built into it, complying with DICOM. A image compression using DWT was also implemented in it. And a unified algorithm of lossless compression and lossy compression was designed to improve images quality and to make compression ratios high. And integrated compression environment was operating together with a database program for efficient and user-friendly management.

  • PDF

Modeling of the Liquid Rocket Engine Transients (액체로켓엔진 천이작동 예측을 위한 동특성 모델링)

  • Ko, Tae-Ho;Jeong, Yu-Shin;Yoon, Woong-Sup
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.45-54
    • /
    • 2011
  • A program aiming at predicting dynamic characteristics of a Liquid Rocket Engine(LRE) was developed and examined to trace entire LRE operation. In the startup period, transient characteristics of the propellant flows were predicted and validated with hydraulic tests data. An arrangement of each component for the pipelines was based on an operating circuit of open cycle LRE. The flow rate ratio for the gas generator and the main chamber was determined to mimic that of real open cycle LRE. Individual component modeling at its transient was completed and was integrated into the system prediction program. Essential parameters of the component dynamic characteristics were examined in an integrated fashion.

A Study on the Critical Success Factors for the Efficient Management of Defense Acquisition Program (효율적인 무기체계 획득을 위한 사업 관리 핵심성공요인 연구)

  • Jeon, Nam-Hee;Kim, Byung-Sam;Kim, Dong-Ho;Gim, Gwang-Yong
    • Journal of the military operations research society of Korea
    • /
    • v.36 no.2
    • /
    • pp.53-69
    • /
    • 2010
  • The long-term purpose of Military Acquisition Program Management (MAPM) is to fulfill requested performance, budget, and timing of military capability building. The Defense Acquisition Program Administration was established in 2006 and it adopted Integrated Control System. Moreover, there have no much studies done to examine the condition of Defense Capability Improvement Project in Korea through an empirical research although there are sixty one organizations are operating currently under Defense Capability Improvement Project. The objective of this study is to recognize Military Acquisition Program Management as a single project and to critically review relationship between Critical Success Factors (CSF) and Military Acquisition Program Management. Accordingly, three determinants to lead to successful Military Acquisition Program Management are "Communication" "User Participation" and "User Requirement." This study also demonstrates that Critical Success Factors have distinctive influences on successful Military Acquisition Program Management based on characteristic, size and phase of project. In retrospect, it is meaningful that Integrated Project Team (IPT) could classify priority of management according to characteristic, size and phase of project in the course of implementation.

Design and Implementation of Wrapper to Support POSIX Standards on UbiFOSTM Real-Time Operating System (UbiFOSTM 실시간 운영체제에서 POSIX지원을 위한 래퍼의 설계 및 구현)

  • Song, Ye-Jin;Cho, Moon-Haeng;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.8
    • /
    • pp.31-40
    • /
    • 2007
  • Recently, Embedded systems are different with the past as loading of a simple application program that executed specific functions according to the use and are evolved in the digital convergence integrated multimedia functions and then the complication of the application program is remarkably increased. This application program is combined and evolved with many application program in accordance with the demand of the age. For develope and manage this developing application is necessary standardized interface between developer and manager. POSIX was developed as the standard of the operating system in the standard interface which has the open system structure in computing system, and there is a posix.4 to standard for the system demands the loading of real-time operating system like a digital convergence devices. In this paper, we present the contents of designing and implementing the real-time operating system UbiFOSTM to wrapper for supporting the POSIX.4. Also, Experimental results show that implemented wrapper to application program standardizing POSIX.4 in linux and UbiFOSTM is slight only $3{\sim}9{\mu}s$.

Implementation of a Simulation Model for a Local Area Network Design

  • Chung, Koo-Don
    • Journal of the military operations research society of Korea
    • /
    • v.11 no.1
    • /
    • pp.55-78
    • /
    • 1985
  • This thesis provides the implementation of a simulation model for a particular Local Area Network (LAN), employs carrier sense multiple access (CSMA) bus architecture, which implements functions of the Stock Point Logistics Integrated Communication Environment (SPLICE). First, specifications of the model are identified based on the given functional specification and operating system design. Then the approach taken for modeling and programming in GPSS is discussed. Finally, the program and results of the simulation run are provided.

  • PDF

A Design on the Digital Protective Relay System for Generator Fault Diagnosis (발전기 고장진단을 위한 디지털보호계전 시스템 설계)

  • Lee, Sung-Hwan;Jang, Nak-Won;Yi, Dong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.717-718
    • /
    • 2008
  • We developed the protection program for the generator fault protection system and each module of the digital protective relay H/W for loading the protection program. The protective algorithm for the generator is 51, 51G/N, 46P/N, 47P/N, 50G/N, and 32, and we developed each fault protection program. And we must design high efficiency microprocessor, CT, and PT for realtime measuring, relaying and high accuracy of measurement, also. From now on digital protective relay must be operated with integrated management systems. For this point, we must load various industrial protocol on the digital protective relay. In this research, we developed each protective relay H/W module according to above conditions. And we designed real-time operating system in order that each protective algorithm is operated with realtime processing on the H/W system.

  • PDF

Concentration of Sodium Chloride Solutions Sensing by Using a Near-Field Microwave Microprobe (비접촉 근접장 마이크로파 현미경을 이용한 NaCl 용액의 농도 측정)

  • Kim, Song-Hui;Yoon, Young-Woon;Babajanyan, Arsen;Kim, Jong-Chul;Lee, Kie-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • We observed the NaCl concentration of solutions using a near-field microwave microprobe(NFMM). Instead of the usual technique, we take advantage of the noncontact evaluation capabilities of a NFMM. A NFMM with a high Q dielectric resonator allows observation of small variations of the permittivity due to changes in the NaCl concentration. The changes of NaCl concentration due to a change of permittivity of the NaCl solution were investigated by measuring the microwave reflection coefficient $S_{11}$ of the resonator. The NaCl sensor consisted of a dielectric resonator coupled to a probe tip at an operating frequency of about f=4 GHz. The change of the NaCl concentration is directly related to the change of the reflection coefficient due to a near field electromagnetic interaction between the probe tip and the NaCl solution. In order to determine the probe selectivity, we measured a mixture solution of NaCl and glucose.

Immobilization of Horseradish Peroxidase to Electrochemically Deposited Gold-Nanoparticles on Glassy Carbon Electrode for Determination of H2O2

  • Ryoo, Hyun-woo;Kim, You-sung;Lee, Jung-hyun;Shin, Woon-sup;Myung, No-seung;Hong, Hun-Gi
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.672-678
    • /
    • 2006
  • A new approach to fabricate an enzyme electrode was described based on the immobilization of horseradish peroxidase (HRP) on dithiobis-N-succinimidyl propionate (DTSP) self-assembled monolayer (SAM) formed on gold-nanoparticles (Au-NPs) which were electrochemically deposited onto glassy carbon electrode (GCE) surface. The overall surface area and average size of Au-NPs could be controlled by varying deposition time and were examined by Field Emission-Scanning Electron Microscope (FE-SEM). The $O_2$ reduction capability of the surface demonstrated that Au-NPs were thermodynamically stable enough to stay on GCE surface. The immobilized HRP electrode based on Au-NPs/GCE presented faster, more stable and sensitive amperometric response in the reduction of hydrogen peroxide than a HRP immobilized on DTSP/gold plate electrode not containing Au-NPs. The effects of operating potential, mediator concentration, and pH of buffer electrolyte solution on the performance of the HRP biosensor were investigated. In the optimized experimental conditions, the HRP immobilized GCE incorporating smaller-sized Au-NPs showed higher electrocatalytic activity due to the high surface area to volume ratio of Au-NPs in the biosensor. The HRP electrode showed a linear response to $H_2O_2$ in the concentration range of 1.4 $\mu$M-3.1 mM. The apparent Michaelis-Menten constant ($K _M\; ^{app}$) determined for the immobilized HRP electrodes showed a trend to be decreased by decreasing size of Au-NPs electrodeposited onto GCE.

Analysis of the Impact of the 8th Basic Plan for Long-term Electricity Supply and Demand on the District Heating Business Through Optimal Simulation of Gas CHP (가스 열병합발전 최적 시뮬레이션 분석을 통한 집단에너지 사업자에 미치는 8차 전력 수급계획의 영향 분석)

  • Kim, Young Kuk;Oh, Kwang Min;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.56 no.5
    • /
    • pp.655-662
    • /
    • 2018
  • To respond effectively to climate change following the launch of the new climate system, the government is seeking to expand the use of distributed power resources. Among them, the district heating system centered on Combined Heat and Power (CHP) is accepted as the most realistic alternative. On the other hand, the government recently announced the change of energy paradigm focusing on eco-friendly power generation from the base power generation through $8^{th}$ Basic Plan for Long-term Electricity Supply and Demand(BPE). In this study, we analyzed the quantitative effects of profit and loss on the CHP operating business by changing patterns of the heat production, caused by the change of energy paradigm. To do this, the power market long-term simulation was carried out according to the $7^{th}$ and $8^{th}$ BPE respectively, using the commercialized power market integrated analysis program. In addition, the CHP operating model is organized to calculate the power and heat production level for each CHP operation mode by utilizing the operating performance of 830MW class CHP in Seoul metropolitan area. Based on this, the operation optimization is performed for realizing the maximum operating profit and loss during the life-cycle of CHP through the commercialized integrated energy optimization program. As a result, it can be seen that the change of the energy paradigm of the government increased the level of the ordered power supply by Korean Power Exchange(KPX), decreased the cost of the heat production, and increased the operating contribution margin by 90.9 billion won for the 30 years.

Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings (주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가)

  • Kim, Deok-Sung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.