• Title/Summary/Keyword: Insulation effect

Search Result 738, Processing Time 0.034 seconds

A study on the safety of the Environment Corrosion of Suspension Insulater of a Catenary Trolley Wire Systems (카테나리 전차선로 현수애자의 환경부식에 따른 안전성 연구)

  • Lee, Jae-Bong;So, Sun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.864-874
    • /
    • 2007
  • Suspension insulator in Catenary Trolley Wire Systems must have two characteristics, electric insulation and mechanical endurance. Because suspension insulator is used in supporting and insulating position between power supply parts and earth conducted supporting parts. The insulator's electric characteristics can be influenced by surface pollution and damage from the environment such as humidity, dust, smoke, salt. etc. And, the insulating parts can be electrically short. These electrically damaged insulator can cause serious accidents that have far-reaching effect. So appropriate management basis of suspension insulator is needed. And we present appropriate cleaning and the changing period of suspension insulator on the basis of actual data.

  • PDF

Effectiveness of a Heat Transfer Characteristics of an Auxiliary Chamber for Performance of an Air Spring (보조용기의 열전달특성이 공기스프링의 성능에 미치는 영향)

  • Jang, Ji-Seong
    • Journal of Power System Engineering
    • /
    • v.17 no.2
    • /
    • pp.121-127
    • /
    • 2013
  • The air spring is used widely because of the easy change of spring constant, and, a superior vibration and shock insulation performance. Among the apparatus using the merits of that, the air spring connected an auxiliary chamber has been developed and used as a component of suspension system for an automobile and a railroad car. The purpose of this study is to suggest a design method reflecting heat transfer effect for an air spring system connected auxiliary chamber. In order to do so, this study investigates change of reaction force along with variations in heat transfer coefficient, and, analyzes an effectiveness of a heat transfer characteristics of an auxiliary chamber for external force attenuation characteristics and impedance characteristics of an air spring connected an auxiliary chamber.

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

Temperature Characteristic of Optical Current Transformer Used Porlarimetric Method (편광측정법을 이용한 광전류 센서의 온도특성)

  • Park, Sang-Man;Ahn, Byeong-Lib;Won, Woo-Sik;Woo, Hyeong-Gwan;Lee, Sung-Gap
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1430-1431
    • /
    • 2008
  • In this paper, a optical current transformer has been designed and favricated to improve temperature stability caused materials properties and insulation in measuring system, suing single crystal as faraday effect cells. We used 850[nm] Laser diode as the light source and PIN Photodiode as receiver. For the experiment, the temperature transformation device make by aluminum. The range of current was from 0[A]$\sim$1600[A] and the range of temperature was from -20[$^{\circ}C$] to 50[$^{\circ}C$]. In a same experimental condition magnitude increased input current increase follow by increasing proportion of input current. The result of this study shows that characteristics of OCT are good, and it can be reflected for practical optical sensors.

  • PDF

The Correlation Study of Factors which effect on Insulation Reliability of Inverter Motor (인버터용 전동기의 절연신뢰성에 영향을 주는 주요 변수의 상관관계 분석)

  • Han, Hoo-Sek;Song, Jhong-Hwan;Ahn, Hee-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.18-20
    • /
    • 2008
  • 산업용전동기는 신뢰성을 바탕으로 설계 및 제작되어 상용전압에 대한 기기의 신뢰성은 충분히 검증되어 있지만 스위칭 소자에 의해 주어지는 펄스상의 전압에 대하여는 신뢰성을 확보하지 못하고 있다. 본 연구에서는 인버터용 전동기의 신뢰성에 영향을 미치는 각종 변수(케이블의 길이, 단자전압, 습도, 온도, 스위칭 주파수 등)들을 검토하고 각 변수들 간의 상관관계를 실험을 통하여 분석하고 이를 통하여 전동기의 신뢰성을 예측할 수 있는 자료를 확보하여 인버터용 전동기의 신뢰성을 제고하고자 한다.

  • PDF

A study on the Relationship between Load Current and Temperature of 6.6 kV Cable Systems in Operation (운전중 6.6kV 케이블 시스템의 부하전류와 온도의 상관관계 연구)

  • Lee, Kwan-Woo;Hwang, Yung-Ha;Lee, Sang-Hun;Um, Keehong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1157-1158
    • /
    • 2015
  • This work is to study the effect of load current on 6.6 kV power cables in operation. In order to figure out the relationship between load current and temperature of the power cables, we have developed measuring equipment for insulation resistance, temperature, and current tested on 9 cables at power station, Western Power Co. Ltd. The cables used in our test were in operation for the last 18 years. Our research over a year showed that the remaining lifetime of 8 cables was more than 20 years. The remaining lifetime of one cable was about 16 to 18 years.

  • PDF

The Effect of Angular Anisotropy in XLPE Insulation on Dielectric Strength (XLPE 케이블의 비등방성이 가지는 전기.기계적 특성)

  • Cho, Dae-Hee;Lee, Sang-Jin;Kim, Young-Ho;Park, Wan-Gi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.432-435
    • /
    • 2003
  • 최근 초고압 케이블 절연체로 XLPE(가교 폴리에틸렌)이 널리 사용되어 지면서 XLPE의 여러 물리 화학적 특성에 따른 절연 성능에 관한 연구가 활발히 이루어지고 있다. 이러한 XLPE 절연층은 제조과정에서 압출과정을 거쳐 도체를 감싸게 되는데 이 과정에서 흐름 패턴으로 나타나는 비등방성(anisotropy)을 띠게된다. 본 논문에서는 초고압 XLPE 케이블에서 시계 방향으로 나타나는 비등방성(anisotropy)이 나타내는 기계-전기적 특성을 인장강도(tensile strength), 트리 개시전압 및 개시시간을 측정한 결과를 토대로 고찰해 보았으며, 이러한 비등방성이 초고압 XLPE 케이블의 절연 성능에 영향을 주는 인자로 고려되어야 함을 알 수 있었다.

  • PDF

The Change of Electrical Properties on Silicone Rubber Contained ATH under Cyclic Aging(I) (ATH를 첨가한 실리콘고무의 반복열화에 따른 전기적 특성변화(I))

  • Oh, Tae-Seung;Lee, Chung;Kim, Ki-Yup;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.258-261
    • /
    • 2001
  • In this paper, aging characteristics of silicone rubber used for outdoor insulation have been investigated with regards to salt fog condition and heat aging effect. We look over the change of properties of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, $Al_2O_3{\cdot}3H_2O$) filler contents. Surface resistivity, SEM(Scanning Electro Microscope) were measured.

  • PDF

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • Lee, Byung-Sung;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

The Application of Pre-Breakdown Partial Discharge Detection Method for Breakdown of Investigation of Long Distance XLPE Cable (장조장 XLPE 케이블 절연 파괴 원인 규명을 위한 전구차단 장치의 응용)

  • Lee, C.Y.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1827-1829
    • /
    • 2002
  • This paper describes AC test for long delivered drum length of cable using pre-breakdown partial discharge detection(PPD) method, which can be applied to observe the causes of electrical breakdown of EHV XLPE insulation. This method is to de-energize applied voltage to cable rapidly using pre-breakdown partial discharge, and is able to prevent complete breakdown. By this effect, defects such as voids, metal particles and protrusion in cable can be observed clearly. AC resonant test set was used for PPD method. Localization of partial discharge was performed by time difference detection of the traveling wave. Accuracy of localization was 1% to the length of test cable. Through several experiments with XLPE cable, successful results of PPD method were obtained.

  • PDF