• 제목/요약/키워드: Insulation effect

검색결과 735건 처리시간 0.031초

자기재/폴리머 계면이 하이브리드 애자의 미세구조, 절연특성과 전계분포에 미치는 영향 (Effect of Porcelain/Polymer Interface on the Microstructure, Insulation Characteristics and Electrical Field Distribution of Hybrid Insulators)

  • 조준영;김우석;안호성;안희성;김태완;임윤석;배성환;박찬
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.558-565
    • /
    • 2017
  • Hybrid insulators that have the advantages of both porcelain (high mechanical strength and chemical stability) as well as polymer (light weight and high resistance to pollution) insulators, can be used in place of individual porcelain and polymer insulators that are used for both mechanical support as well as electrical insulation of overhead power transmission lines. The most significant feature of hybrid insulators is the presence of porcelain/polymer interfaces where the porcelain and polymer are physically bonded. Individual porcelain and polymer insulators do not have such porcelain/polymer interfaces. Although the interface is expected to affect the mechanical/electrical properties of the hybrid insulator, systematic studies of the adhesion properties at the porcelain/polymer interface and the effect of the interface on the insulation characteristics and electric field distribution of the hybrid insulator have not been reported. In this study, we fabricated small hybrid insulator specimens with various types of interfaces and investigated the effect of the porcelain/polymer interface on the microstructure, insulating characteristics, and electric field distribution of the hybrid insulators. It was observed that the porcelain/polymer interface of the hybrid insulator does not have a significant effect on the insulating characteristics and electric field distribution, and the hybrid insulator can exhibit electrical insulating properties that are similar or superior to those of individual porcelain and polymer insulators.

열과 관련된 문제 상황에서 초등학생들이 느끼는 친숙도, 인지에 대한 지각, 상태호기심, 상태불안의 관계 분석 (Analysis of the Relationship between Familiarity, Feeling of Knowing, State Curiosity, and State Anxiety of Elementary School Students in the Thermal Task Contexts)

  • 강지훈;김지나
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제39권3호
    • /
    • pp.433-448
    • /
    • 2020
  • In this study, the tasks of thermal equilibrium and heat insulation concept were divided into scientific and everyday contexts to analyzed the level of familiarity, feeling of knowing, state curiosity, and state anxiety that students feel in task contexts and their relationship. The subjects of this study were One hundred nine students in sixth grade of elementary schools located in metropolitan cities. The results of this study were as follows. First, there was no difference in the level of feeling of knowing, state curiosity, and state anxiety in the task of scientific and everyday contexts. In the case of familiarity, there was no consistent tendency in the concept of thermal equilibrium and heat insulation. And the group who recognized the task context familiarly had higher feeling of knowing and lower state anxiety than the group who recognized the task context unfamiliarly. Second, familiarity and feeling of knowing showed high positive correlation, state anxiety and familiarity showed negative correlation, and state anxiety and feeling of knowing had also negative correlation. In addition, familiarity had a negative effect on state anxiety, and FOK had a positive effect on state curiosity and a negative effect on state anxiety. There was no significant moderating effect of the task context. Third, in case of state curiosity, the group perceived the knowledge gap was very small had the highest state curiosity, and the group perceived the knowledge gap was very large had the lowest state curiosity. In case of state anxiety, the less the knowledge gap was perceived, the lower the anxiety was triggered. This study broadens our understanding of the learning process and provides implications for effective instruction strategies for students' cognitive and emotional states.

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

섬유보강 다공성 옥상녹화 황토콘크리트의 물리·역학적 및 온도변화 특성 평가 (Physical·Mechanical and Temperature Properties of Fiber Reinforced Porous Green Roof Hwang-toh Concrete)

  • 오리온;김춘수;김황희;전지홍;권완식;박찬기
    • 한국농공학회논문집
    • /
    • 제55권4호
    • /
    • pp.65-72
    • /
    • 2013
  • The physical, mechanical, water purification and temperature properties of fiber reinforced porous hwang-toh green roof concrete have been evaluated in this study. The effect of the depending on replacement ratio of blast furnace slag to cement was investigated such that the replacement ratio is varied to 0 % and 30 %. Also, the replacement ratios of hwang-toh were 0, 20 and 30 %. The polyvinyl alcohol fiber was used for the reinforcing fiber. A series of pH test, unit weight, void ratio, compressive strength, after purification and variation of temperature test have been performed to evaluate the performance, water purification effect and temperature properties of the fiber reinforced porous hwang-toh green roof concrete. The test results indicate that the physical and mechanical properties of fiber reinforced porous hwang-toh green roof concrete is affected by the replacement ratio of the blast furnace slag and hwang-toh contents. Results of purifying water showed that the water purification effect of porous hwang-toh green roof concrete is about 40 %. Also, the temperature properties test results indicate the green roof blocks using fiber reinforced porous hwang-toh green roof concrete have insulation and temperature reduction effect.

유리섬유복합체를 사용한 전단연결재 형상에 따른 중단열 벽체의 면내전단내력 (Effect of Glass Fiber-Reinforced Polymer (GFRP) Shear Connector's Shape on Inplane Shear Strength of Insulated Concrete Sandwich Panels)

  • 장석준;유영찬;김호룡;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.9-17
    • /
    • 2013
  • 최근, 중단열 벽체의 단열성능 향상을 위해 철과 콘크리트 코어 전단연결재를 열전도율이 낮은 유리섬유복합체 (GFRP)로 전단연결재를 대체하는 연구가 활발히 진행되고 있다. 본 연구는 단열재의 표면처리에 따른 부착력과, GFRP 전단연결재로 보강된 중단열 벽체의 전단내력을 알아보기 위하여 실시되었으며, 각 변수에 따른 영향을 분석함으로써 구조성능에 대한 검증을 실시하였다. 총 13개의 실험체에 대해 직접전단실험을 실시하였으며, 파괴양상 및 하중-상대슬립 관계에 대한 분석을 실시하였다. 실험결과, 기존의 압출법 보온판 (XPS) 단열재에 거친표면처리와 10 mm의 홈을 낸 경우 단열재와 콘크리트사이에 부착력을 향상시킬 수 있으며, 부착력의 기여는 전단연결재의 파단 상대슬립의 영향을 받는 것으로 나타났다. 파형 전단연결재의 폭이 커짐에 따라 강성이 증가하였으며, 보강단면적이 증가함에 따라 최대내력이 증가하였다. 효과적인 보강을 위해서는 파형 전단연결재의 높이와 피치의 비율을 1:2로 산정해야 할 것으로 판단되며, 안정적인 파괴를 위해서는 매립깊이에 대한 검증이 필요할 것으로 사료된다.

복숭아 주간부 동해 예방을 위한 피복재의 보온성 평가 (Evaluation of Thermal Insulation Properties of Covering Materials to Protect Peach Trunks against Freezing Injury)

  • 신현석;윤석규;최인명;김성종;윤익구;남은영;권정현
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.288-293
    • /
    • 2016
  • 본 연구는 복숭아 주간부 동해 예방을 위한 피복재의 보온성을 평가하기 위해 백색부직포, 황색일반지, 방수패드로 만들어진 피복재의 물리적 특성 및 보온성을 평가하고 실제 겨울철 복숭아 주간부 보온효과를 구명하여 피복재로서의 이용가능성을 검토하기 위해 수행하였다. 세 피복재 중 2겹방수패드 처리가 보온율과 열저항성이 가장 우수하였다. 2겹방수패드 처리의 주간단열효과는 $14.09^{\circ}C$ 만큼 온도상승을 차단하였고, 야간보온효과는 $7.23^{\circ}C$ 만큼 온도하강을 차단하여 보온효과가 가장 우수함을 확인하였다. 따라서 방수패드 재질을 보온피복재로 개발 보급할 경우 복숭아 주간부 동해 피해를 경감시키는데 도움을 줄 수 있을 것으로 생각되었다.

금속진공단열패널의 심재용 기포콘크리트의 성능에 관한 연구 (A Study on the Performance of Foamed Concrete for Cores Material of Metal Vacuum Insulation Panel)

  • 홍상훈;김봉주
    • 한국건축시공학회지
    • /
    • 제20권5호
    • /
    • pp.417-423
    • /
    • 2020
  • 건축물의 에너지 소비 중 40%인 냉·난방을 줄이기 위해 외피 단열향상이 중요시되고 있다. 이에 기존 단열재를 개선하기 위해 진공단열패널VIP(Vacuum Insulation Panel)을 건축물에 적용하기 위한 연구가 진행되고 있다. 하지만 VIP는 보수보강이 불가능해 이를 개선한 금속진공단열패널을 고려하였다. 금속진공단열패널의 심재는 진공압력을 버티고, 낮은 열전도율을 가져야 하므로 기포콘크리트를 채택하였다. 하지만 예비 실험을 통해 기포의 양이나 성질에 의해 0.001torr에 도달하는 시간이 다른 것을 확인하였다. 이러한 영향은 기포제의 종류 및 기포 슬러리 밀도 등에 의해 진공도달시간이 달라질 것이라 판단하여 최적 기포콘크리트 조건이 필요하다. 따라서 본 연구에서는 금속진공단열패널의 심재인 기포큰크리트의 기포제 종류 및 기포 슬러리 밀도에 따라 진공도달시간 및 열전도율 변화를 측정하여 심재로 적용 가능한 기초적 자료를 제시하는 것을 연구목적으로 한다.

외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과 (Improvement of sound insulation performance of windows according to the specifications of the external electric blinds)

  • 강민우;이희동;오양기
    • 한국음향학회지
    • /
    • 제41권6호
    • /
    • pp.621-628
    • /
    • 2022
  • 도로교통 소음이나 항공기 소음 등의 건물 외부소음을 저감하기 위한 가장 현실적인 방안은 각 건물의 발코니와 창호, 외벽 등 수음점에서의 차음성능을 강화하는 것이다. 그러나 아직 건물 외부의 차양장치가 광범위하게 사용되지 않고 있는 현실에 비추어 루버나 블라인드 등의 창호 외부장치를 활용하는 차음성능 개선 연구는 많지 않다. 특히 외장형 블라인드는 아침-저녁의 강한 일사의 유입을 건물 외부에서 차단하는 차광 효과 뿐 아니라 출퇴근 시간대에 발생하는 피크 소음을 차단하는 차음 효과도 동시에 목표할 수 있다. 이 연구에서는 가장 효율적인 창호 외부 차양장치의 하나인 외부 전동블라인드(External Electric Blind, EEB)를 활용하여 외부소음에 대한 차음성능을 개선하고자 하는 연구를 수행하였다. 차광 용도로 개발된 외부 전동블라인드의 구성을 변화시켜가면서 다양한 차음성능 실험을 수행하였다. 이를 통해 일반 창호의 저감 성능 대비 외부 전동블라인드를 설치함으로써 6 dB의 추가 차음성능을 얻을 수 있음을 검증하였다.

단열양생시트 종류 변화에 따른 한중콘크리트의 온도이력 (Temperature History of Concrete at Cold Weather Depending on the Kinds of Insulating Sheet)

  • 전충근;김종;신동안;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.618-621
    • /
    • 2006
  • This paper is to investigate temperature history of cold weather concrete depending on insulation curing sheet kinds. Insulating effect according to curing sheet is shown in order of 5 layer bubble sheet, combination of PE form and 3 layer bubble sheet and 3 layer bubble sheet. It maintained above $10^{\circ}C$ of minimum temperature until the completion of initial curing period when bubble curing sheet was supplied regardless of curing sheet kinds. Five layer bubble curing sheet secure higher curing temperature than any other curing sheet applied in this experiment by as much as $2{\sim}3^{\circ}C$, which performed remarkable insulation effect. Concrete applied with curing sheet secured above $65^{\circ}D{\cdot}D$ of maturity, at which concrete had 5MPa of compressive strength at 3 days.

  • PDF

간이 잔향실의 음향성능 (Acoustic Performance of a Scaled Reverberation Chamber)

  • 강현주;김봉기;김재승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.101-104
    • /
    • 2005
  • This study presents experimental results from the performance test of a scaled reverberation chamber for measurement of sound insulation of panels. Experimental investigations were conducted in various parameters such as tunneling effect source locations, and maximum sound transmission loss. It is evident that the tunneling effect which means the variation with specimen location on the test frame gives rise to more than 3 dB deviation. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF