In order to reduce cooling and heating, which is 40% of the energy consumption of buildings, it is important to improve the insulation of the skin. In order to improve the existing insulation, research is being conducted to apply a vacuum insulation panel(VIP) to buildings. However, VIP cannot be repaired, so we considered the metal vacuum insulation panel. Since the core of the metal vacuum pressure and have low thermal conductivity, foam concrete is adopted. However, preliminary experiments confirmed that the time to reach 0.001torr differs depending on the amount and nature of the bubbles. This effect is determined by the type of foaming agent and the density of the bubble slurry, the vacuum delivery time is determined to be the optimum foam concrete conditions are necessary. Therfore, this study aims to present basic data applicable to core materials by measuring vacuum delivery time and thermal conductivity change according to the foaming agent type and foam slurry density of foam large concrete which is core material of metal vacuum insulation panel. Experimental results and analysis show that compressive strength can be used regardless of the type of foam, In terms of thermal conductivity, it is stable to use vegetable foaming agents at 0.9g/㎤ or less. In terms of the vacuum delivery time, the foaming agent appeared similar regardless of the type of foaming agent, but it is considered suitable to use vegetable foaming agent based on compressive strength and thermal conductivity.

건축물의 에너지 소비 중 40%인 냉·난방을 줄이기 위해 외피 단열향상이 중요시되고 있다. 이에 기존 단열재를 개선하기 위해 진공단열패널VIP(Vacuum Insulation Panel)을 건축물에 적용하기 위한 연구가 진행되고 있다. 하지만 VIP는 보수보강이 불가능해 이를 개선한 금속진공단열패널을 고려하였다. 금속진공단열패널의 심재는 진공압력을 버티고, 낮은 열전도율을 가져야 하므로 기포콘크리트를 채택하였다. 하지만 예비 실험을 통해 기포의 양이나 성질에 의해 0.001torr에 도달하는 시간이 다른 것을 확인하였다. 이러한 영향은 기포제의 종류 및 기포 슬러리 밀도 등에 의해 진공도달시간이 달라질 것이라 판단하여 최적 기포콘크리트 조건이 필요하다. 따라서 본 연구에서는 금속진공단열패널의 심재인 기포큰크리트의 기포제 종류 및 기포 슬러리 밀도에 따라 진공도달시간 및 열전도율 변화를 측정하여 심재로 적용 가능한 기초적 자료를 제시하는 것을 연구목적으로 한다.

Keywords

References

  1. Park SH, Lim JH, Song SY. Performance evaluation of adhesively fixed external insulation and finish system using vacuum insulation panels for apartment buildings. KIEAE Journal. 2013 Dec;13(6):45-53. https://doi.org/10.12813/kieae.2013.13.6.045
  2. Song SY, Park SH, Koo BK, Lim JH, Ryu SR. Performance evaluation of EIFS using vacuum insulation panels for passive and zero-energy apartment buildings. Journal of the Architectural Institute of Korea Plannig and Design. 2013 Sep;29(9):219-28. https://doi.org/10.5659/JAIK_PD.2013.29.9.219
  3. Koo BK, Park SH, Lim JH, Song SY, Ryu SR. Energy performance analysis eifs using vacuum insulation panel. Proceeding of Annual Conference of the Architectural Insititute of Korea; 2012 October 25; Gwangju, Korea. Seoul (Korea): Architectural Institute of Korea; 2012. p. 333-4.
  4. Min DH, Kim SM, Kim JH, Kim JT. A Study on the insulation performance analysis of the exterior insulation system with vacuum insulation panels. Proceedings of the Korean Korea Institute of Ecological Architecture and Environment 2018 Nov 23; Seoul, Korea. Seoul (Korea): Korea Institute of Ecological Architecture and Environment; 2018. p. 132-3.
  5. Lee KW, Cho SW, Kim JM, Kim SW, Song TH. Modeling and shape optimization of vacuum insulator support. Proceedings of the Korean Society for Precision Engineering; 2011 Jun 01-03; Jeju, Korea. Seoul (Korea): Korean Society for Precision Engineering; 2011. p. 1113-4.
  6. Yoon YH, So BS, Cho JH, Eom YC. Numerical study on the Evaluation of thermal Bridges in structure of VIPs. Proceedings of the Korean society of manufacturing Process Engineers Conference; 2016 Oct13-14; Busan, Korea. Daegu (Korea): Korean society of manufacturing Process Engineers; 2016. p. 40