• 제목/요약/키워드: Indoor/Outdoor concentration

검색결과 187건 처리시간 0.021초

건축물 실내 CO2 농도 분포에 따른 콘크리트 탄산화 깊이 산정에 관한 연구 (Analytic Expectation of Carbonation Depth of Indoor Concrete According to CO2 Concentration)

  • 박동천;박근석;안재철;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.231-233
    • /
    • 2011
  • Carbon dioxide in atmosphere causes concrete carbonation which is the phenomenon, that is, the pH of concrete changes from 12-13 to 8.85-10. Even though the carbon dioxide concentration of indoor is higher than that of outdoor, the micro measurement has not carried out. The concentration of carbon dioxide was measured in three places. The data was used as boundary condition to FEM analysis for expectation of concrete carbonation depth. The affect of building finish materials to concrete carbonation was discussed.

  • PDF

변위환기를 이용한 대형 용접작업장의 공기환경 개선에 관한 연구 (Improvement of Indoor Air Environment in a Large Welding Factory by Displacement Ventilation)

  • 조동환;강석윤;최충현;임윤철;이재헌;문정환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.69-74
    • /
    • 2005
  • In this paper, the indoor air environment in a large welding factory applied to displacement ventilation was investigated with experiment and numerical analysis for previous and new ventilation system. Concentration of fumes was analyzed for three cases with wind direction of outdoor. For experimental results, the dust concentration with new ventilation system decreased about 42-60% and the visibility increased about 11-18%. For numerical analysis, the exhaust efficiency of fumes was low when the wind and exhaust flow direction was inverse. It was found that the fumes in the factory decreased about 77% in case of the northern wind.

  • PDF

시뮬레이션을 통한 노인 요양 시설의 지열 히트펌프 시스템 적용 가능성 평가 (Evaluating the Feasibility of a Ground Source Heat pump System for an Elderly Care Center through Simulation Approach)

  • 손병후;김영선;이승언
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.39-52
    • /
    • 2023
  • This study analyzes the energy performance of a elderly care center building and the applicability of a ground source heat pump (GSHP) system through simulation approach. For this purpose, a building information modeling (BIM) program and an energy performance calculation program were used. The impact of the mechanical ventilation system on the energy requirements of the heating and cooling system and the indoor environment was also analyzed, focusing on the change in indoor carbon dioxide (CO2) concentration, which is a representative indicator of the indoor environment (air quality). The simulation results showed that the target building exceeds Level 7 in terms of simulated primary energy consumption or actual energy consumption. In addition, it was analyzed that the target building could not maintain the indoor CO2 concentration below the standard concentration by natural ventilation through window opening alone. Combining the GSHP system with the mechanical ventilation system (Case B and Case C) can further reduce the overall energy consumption by reducing the amount of outdoor air introduced by opening windows. The cost savings compared to the baseline case are estimated to be 67.3% for Case A, 63.7% for Case B, 65.5% for Case C, and 42.5% for Case D. It is necessary to analyze the impact of various renewable energy technologies and passive ones on the energy performance and indoor environment of elderly care centers.

실내공기중의 휘발성유기화합물 농도변화에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in the Apartment House)

  • 이윤규
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.129-136
    • /
    • 2004
  • Recently, indoor air pollution has been seriously apprehended, and became a striking issue, due to the airtightness of buildings or the misuse of building materials. Especially, SHS(Sick House Syndrome) and MCS(Multi Chemical Sensitivity) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. The emission rates of VOCs is sensitively affected by the indoor/outdoor condition, construction materials, construction method, and character of ventilation facilities. Therefore, in this study, by measuring the indoor air pollution substance of the existing apartment house, the problem over this tends to be grasped and it is going to secure an improvement methods.

실내 공기 중 일부 알데하이드류에 대한 위해도 평가 - 일부 주택 및 아토피 환자 주택을 대상으로 (Risk Assessment of Aldehydes in Some Residential Indoor Air Included Atopy Patient's Homes)

  • 문경환;변상훈;최달웅;이은일;오은하;김영환
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.19-26
    • /
    • 2006
  • This study was undertaken to determine the concentrations of 15 aldehydes in air samples collected from 21 households including 9 atopy patient's homes and to assess the extent of exposure and risk for an individual due to inhalation. Of all the aldehydes identified in both indoor and outdoor environment, formaldehyde and acetaldehyde were the most abundant aldehydes, which were occupied $60\%\;and\;17\%$ of total amount, respectively. The geometric mean concentration of formaldehyde and acetaldehyde in indoor air were $170.5\pm1.9\;{\mu}g/m^3\;and\;47.3\pm1.5\;{\mu}g/m^3$, respectively. There existed a strong correlation between formaldehyde, acetaldehyde and other aldehydes. And the ratio of indoor and outdoor concentrations (I/O) exceeded 1.0 for almost every measured aldehydes except m-tolualdehyde... No associations were found between the level of aldehydes and either housing characteristics or living habits in most of the samples with only a few exception. And the concentrations of all aldehydes indoor air between atopy patient's homes and control homes were not significant(p>0.05). Formaldehyde and acetaldehyde exposures and risks were estimated by using the inhalation unit risk, mean concentrations and the 95th percentiles, and which were $2.6\times10^{-3}\;and\;1.1\times10^{-4}$, respectively. The mean and the 95th percentile risk estimates were 25 times higher for formaldehyde than for acetaldehyde in homes.

Exposure Assessments for Children in Homes and in Daycare Centers to NO2, PMs and Black Carbon

  • Lee, Jae Young;Kim, Changhyeok;Kim, Jongbum;Ryu, Sung Hee;Bae, Gwi-Nam
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권3호
    • /
    • pp.204-214
    • /
    • 2018
  • Indoor air quality was investigated in homes and daycares located in areas with heavy traffic in Seoul, South Korea from November 2013 to January 2014. Indoor and outdoor air quality measurements were collected for 48 hours in four children's homes and daycare centers. The I/O ratio (Indoor to outdoor ratio) for each major air pollutant ($NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$) was calculated, and $NO_2$ and $PM_{10}$ concentration profiles were analyzed based on indoor activity diaries recorded during the 48 hours. Most I/O ratios for $NO_2$, black carbon, $PM_{10}$, and $PM_{2.5}$ at daycare centers were less than one. At homes, I/O ratios for black carbon, $PM_{10}$, and $PM_{2.5}$ were less than one; however, most I/O ratios for $NO_2$ were greater than one due to the usage of gas stoves. The children's exposure to indoor air pollutants was calculated using a time-weighted average exposure method, and the daily intake level for each pollutant was determined.

실내조명용 화이버 광학 집광기의 성능에 관한 실험적 평가 (Experimental Evaluation of a Fiber Optic Concentrator for Daylighting)

  • 한현주;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.27-34
    • /
    • 2008
  • A series of outdoor tests were conducted on a fiber optic solar concentrator system for its performance on daylighting. The system is comprised of four main components - a parabolic dish reflector, a convex mirror, a homogenizer tube and an optical fiber cable. Results show that the system could be successfully applied for indoor lighting if some improvements are made for light transmiting (optical) cables. A maximum concentration ratio of 90 was observed delivering the illuminance of 4,800 lux at a distance of 1.2m from the diffuser for the outdoor illuminance of 102,100 lux.

서울시의 대중교통수단내 실내공기질에 대한 연구 (An Investigation of Indoor Air Quality of Public Transportation System in Seoul City)

  • 김윤신;홍승철;전준민
    • 한국환경보건학회지
    • /
    • 제20권1호
    • /
    • pp.28-38
    • /
    • 1994
  • The objective of this study were to measure concentrations of indoor pollutants in public transportation systems to provide importance of indoor air quality in transportation systems to policy makers. Indoor air quality of the pollutants (CO, CO$_2$, PM-10) and environmental sources (temperature, humidity) were measured at subway, seat-type bus, and city-type bus in the Seoul area from April to September 1992. The same pollutants and environmental sources were also measured at selected bus stops and subway stations during October 1991-September 1992. The mean concentrations of indoor pollutants in the public transportation systems were showed 115.5 $\mu$g/m$^3$ in PM-10, 6.8 ppm in CO, and 2167.9 ppm in CO$_2$, respectively. The mean values of PM-10 and CO showed below the U.S. 24 hour standard value of PM-10 and the Korea ambient CO standard, while the mean concentrations of CO$_2$ exceeded the Korea CO$_2$ standard. The highest levels of indoor concentration at public transportation systems were PM-10 of 134.6 $\mu$g/m$^3$ in the subway, CO of 8.9 ppm in the city-type bus, CO$_2$ of 2,511.1ppm in seat-type bus, respectively. The results showed that indoor air quality in bus and subway seemed likely to be affected by number of passengers and outdoor air infiltrated from exhausted gases of automobiles.

  • PDF

실시간 교통량을 이용한 고속도로 요금소 대기요염도 예측 (Air Pollution prediction at Highway Tollgate by Using Real Time Traffic Volume)

  • 박성규;김신도;이정주
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.134-140
    • /
    • 2000
  • The increase in traffic is a worldwide phenomenon. In Korea, it has been increased by 20% per annual in recent 1990’s and approximately 10 millions cars had been registered until 1997. This traffic could easily affect and contribute the local outdoor air quality(QAQ) concerned. The QAQ in highway in one of the examples and the subject in this study. The seoul tollgate located at the north-end of Keypngbu Highway was selected for the study. In case of highway tollgate, the local air pollution could be directly affected by the traffic to approach, wait and start the tollgate. Nitrogen dioxide (NO$_2$) concentration exceeded the EAQS(Environmental Air Quality Standards), but overall indoor air quality was a little better than the outdoor air quality. The measured TSP concentration was much higher than that of the EAQS. To apply a management to a air quality problem of Seoul tollgate, it was predicted air quality with traffic volume and weather condition. It was calculated NO$_2$ emission with traffic volume and predicted in and out of booth by CALINE3 at the Seoul tollgate. To make a comparison between measured and predicted concentration, the prediction was good. It was shown that NO$_2$ concentration was high in the morning at the from Seoul direction and in the evening at the to Seoul direction. it was thought that NO$_2$ concentration variation was reflected according to the traffic volume.

  • PDF

가정 내 부유 진균의 농도와 관련 요인 (Airborne Fungi Concentrations and Related Factors in the Home)

  • 조용민;류승훈;최민석;서성철;정지태;최재욱
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.438-446
    • /
    • 2013
  • Objectives: This study was performed in order to determine airborne fungi levels in homes and find related factors that may affect airborne fungi concentration. Methods: Fifty homes were study subjects for measuring airborne fungi. For sampling airborne fungi, the impaction method on agar plates was used and samples were counted as colony forming units per cubic meter of air ($CFU/m^3$). In addition, information regarding housing characteristics and atopic disease in each home were collected via questionnaire. Results: The geometric means (GM) of airborne fungi concentrations in fifty living rooms and bedrooms were 68.03 and 62.93 $CFU/m^3$, respectively. The GM of airborne fungi concentration in atopy homes was 78.42 $CFU/m^3$. This was higher than non-atopy homes' 54.34 $CFU/m^3$ (p-value=0.051). In the results of the multiple regression analysis, outdoor airborne fungal concentration proved a strong effective factor on indoor airborne fungal concentration. Also, construction year, floor area of house, indoor smoking and frequency of ventilation were factors that showed a significant association with indoor airborne fungi concentration. Conclusions: The results of this study show that some housing and living characteristics may affect the development and increase of airborne fungi. In addition, exposure to airborne fungi may be a risk factor for the prevalence of childhood atopic diseases.