• Title/Summary/Keyword: Impedance meter

Search Result 61, Processing Time 0.025 seconds

A Study on the development and calibration method of a modular internal resistance meter to improve the safety of reusable batteries

  • Mi-Jin Choi;Sang-Bum Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.228-235
    • /
    • 2024
  • Battery use is increasing worldwide to achieve carbon neutrality and improve energy efficiency, but batteries are a finite resource and their application is determined by capacity and specifications. Battery performance deteriorates as the number of uses increases. A certain level of battery performance degradation has become an issue in the field of reuse and recycling, and various studies are being conducted on reuse to solve power shortages. Waste batteries from electric vehicles are suitable for building ESS based on reusable batteries, and for stable use, technical skills are needed to accurately predict battery life and determine status information. Predicting battery life and determining status information are difficult due to non-linearity due to internal structure or chemical changes. In this paper, we manufactured a modular internal resistance measuring device and compared the measured values with Hioki equipment to minimize the error rate through a correction method. As a result of testing Hioki equipment and modular measuring instruments to ensure efficiency and safety based on reusable batteries, an accuracy of over 95% was confirmed.

Preparation of Bio-Chemical Sensor Electrodes by Using Electrical Impedance Properties of Carbon Nanotube Based Bulk Materials (탄소나노튜브 기반 벌크 소재의 전기적 임피던스 특성을 이용한 생화학 센서용 전극 개발 연구)

  • So, Dae-Sup;Huh, Hoon;Kim, Hee-Jin;Lee, Hai-Won;Kang, In-Pil
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.495-499
    • /
    • 2010
  • To develop chemical and biosensors, this paper studies sensing characteristics of bulk carbon nanotube (CNT) electrodes by means of their electrical impedance properties due to their large surface area and excellence chemical absorptivity. The sensors were fabricated in the form of film and nano web style by using composite process for mass production. The bulk composite electrodes were fabricated with singlewall and multi-wall carbon nanotubes based on host polymers such as Nafion and PAN, using a solution-casting and an electrospinning technique. The resistance and the capacitance of electrodes were measured with LCR meter under the various amounts of buffer solution to study the electrical impedance change properties of them. On the experimental of sensor electrode, impedance characteristics of the composite electrode are affected by its host polymer and nanofiller and its sensing response showed saturated result after applying some amounts of buffer solution for test chemical. Especially, the capacitance values showed drastic changes while the resistance values only changed within few percent range. It is deduced that the ions in the solution penetrated and diffused into the electrodes surface changed the electrical properties of the electrodes much like a doping effect.

Characterization of the Material Properties of 0.68Pb ($Mg_{1}$3/$Nb_{2}$3/)$O_3$-0.32PbT$iO_3$ Single Crystals Grown by the Solid-State-Crystal-Growth Method (고상단결정법으로 성장시킨 0.68Pb ($Mg_{1}$3/$Nb_{2}$3/)$O_3$-0.32PbT$iO_3$ 압전단결정의 물성평가)

  • 이상한;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • In this paper, all the materials constants of the PMN-32%PT single crystals grown by the solid state crystal growth method were measured by the resonance method. PMN-PT crystals of tetragonal symmetry have six elastic constants, three piezoelectric constants and two dielectric constants for their independent material constants. These materials constants were extracted from six sets of crystal samples of each different geometry to have different vibration modes respectively. Measured results showed that the crystal has larger electromechanical coupling factor k/sub 33/ (∼86%) and piezoelectric constant d/sub 33/ (∼1200pC/N) than conventional piezoceramics. Validity of the measurement was confirmed through comparison of the results with the impedance spectrum from finite element analysis of the samples and the results measured with a commercial do meter.

Development of Inspection System for Transparent Pattern of the Electromagnetic Resonance Pen (전자펜 입력용 투명패턴 검사장치 개발)

  • Ryu, Young Kee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.640-645
    • /
    • 2020
  • To produce an input device stably using the transparent electromagnetic pattern of an electromagnetic induction method, pattern inspection is required in advance in the production process. Various methods of inspecting the capacitive pattern for hand-touch have been proposed, but it is difficult to find the related technical data for the pattern inspection method of the transparent electromagnetic induction method. In this study, to develop an inspection system for a fused electromagnetic resonance pen sensor with a copper-etched metal mesh pattern, an inspection algorithm and method for measuring the antenna impedance inside the sensor was proposed by measuring only the exposed FPCB connector. The proposed method was configured as a control board consisting of a microprocessor that forms a loop between specific channels according to the command of a computer, a computer-controlled by the Windows program, an LCR meter measuring the impedance between specific channels, and transmitting the measurement results back to the computer. An evaluation of the proposed system and measurements of nine specimens showed that it could detect the defects of the sensor used in the actual product.

Relationship of Body Fat Percent with Serum Lipid Level and Blood Pressure in Adults (Impedance Fat Meter로 측정한 체지방 비율과 혈청 지질치 및 혈압과의 관련성)

  • Lee, Seock-Whan;Hwang, Tae-Yoon;Kim, Chang-Yoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.783-794
    • /
    • 1995
  • This study was conducted to clarify the relationship of body fat percent with serum lipid level and blood pressure in adults. The study subjects were 472 men and 189 women who visited Multiphasic Health Screening Center of Yeungnam University Hospital in Taegu from May 20 to September 30, 1994. The relationship of serum lipid and blood pressure with BMI, Katsura index, atherogenic index, which calculated from the health screening data and body fat percent measured by impedance fat meter(model SIF-819) were analyzed. Three groups were classified as Group I (men : body fat Percent $\geq$ 20, women : body fat percent $\geq$ 25), Group II (men : 15 $\leq$ body fat percent< 20, women : 20 $\leq$ body fat percent< 25), Group III(men : body fat percent < 15, women body fat percent <20). In this study, Group I accounted for 3.2% in men, 3.7% in women. Weight was significantly different among three groups in both sexes(p<0.01) and height was not significantly different among three groups. In men, serum total cholesterol, triglyceride, high density lipoprotein, low density lipoprotein, atherogenic index were significantly different(p<0.01). In women, serum total cholesterol and low density lipoprotein were significantly different(p<0.05) but there was no differences in triglyceride and high density lipoprotein among three groups. BMI and Katsura index were significantly different among three groups in both sexes(p<0.01). In men, body fat percent was positively correlated with weight, BMI, Katsura index, total cholesterol, triglyceride, low density lipoprotein, atherogenic index and systolic and diastolic blood pressures, and negatively correlated with high density lipoprotein. In women, body fat percent was positively correlated with age, height, weight, BMI, Katsura index, total cholesterol, triglyceride, low density lipoprotein and atherogenic index, and negatively correlated with high density lipoprotein. But there was no significant correlation between body fat percent and blood pressure in women. In multiple regression analysis for total cholesterol, fat percent, age and BMI were significant independent variables in men$(p<0.05,\;R^2=0.1286)$, and body fat percent and age in women$(p<0.05,\;R^2=0.3399)$. In case of LDL/HDL ratio, only BMI was a significant independent variable in menu$(p<0.01,\;R^2=0.0954)$, and body fat percent, age and BMI in women$(p<0.05,\;R^2=0.3164)$. In multiple regression analysis, age, low density lipoprotein and total cholesterol were significant independent variables on systolic blood pressure in men$(p<0.05,\;R^2=0.1297)$, age and total cholesterol in women$(p<0.05,\;R^2=0.1705)$. On diastolic blood pressure, only age was a significantly independent variable in men$(p<0.01,\;R^2=0.0972)$ and women$(p<0.01,\;R^2=0.1218)$. From the result of this study, it could concluded that body fat percent was significantly associated with other obesity indices and serum lipid, but had no significant association with blood pressure. To establish the relationship of body fat percent with blood pressure, further study which consider other variables that may have an effect on blood pressure should be performed.

  • PDF

Effectiveness of a consulting program through telephone in treating obese women (전화 상담을 통한 비만 여성의 치료 효과)

  • Park, Gwi-Seon
    • Journal of the Korean Dietetic Association
    • /
    • v.2 no.2
    • /
    • pp.105-111
    • /
    • 1996
  • The trial was conducted to assess the impact of consulting through telephone on body weight reduction among 18 obese adult women. The degree of obesity, food intake pattern, and life style were examined through phone calls. Subjects visited our clinic and their body fat percentages were measured using impedance fat meter (model SIF-891), and were recommended and recorded to have a low calory diet with changes in the food habit and behavior. The study results are as follows: 1. There is a positive relationship between food habit, lifestyle, obese degree, and fat percentage. 2. 8-10kg and 5kg reductions in the body weight were observed among 14 subjects and 2 subjects, respectively. However, 2 subjects maintained their body weights. 3. The body reduction curve looked like a stairway (type) with low slope and was related with food intake amount. 4. It was possible to have the adequate protein intake only through the vegetable diet. 5. 15 out of 18 subjects were on the prescribed low calory diets for 3 days. Therefore, there is a time limitation to follow the diet treatment. 6. A body weight reduction altered dietary intake of foods which were rich in sweet taste, and the favorite foods were chocolate and candy.

  • PDF

Calibration of Frequency Response for a Sampling Oscilloscope (샘플링 오실로스코프의 주파수 응답특성 교정)

  • Cho, Chihyun;Lee, Dong-Joon;Lee, Joo-Gwang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.5
    • /
    • pp.344-352
    • /
    • 2018
  • We herein propose a calibration method for a sampling oscilloscope. The proposed method can correct the systematic errors in the oscilloscope such as time-based distortion and impedance mismatch. In addition, it can accurately estimate the residual jitter that remains after a time-based correction and the scale factor that varies in accordance with the setting of the pulse generator. The proposed method is validated thorough the comparison and verification with the power meter, and the uncertainty of the measurement method is analyzed.

A Study on the Linear Counting Ratemeter (선형 계수율계에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.6
    • /
    • pp.8-16
    • /
    • 1971
  • This paper describes the transistorized linear counting ratemeter which can be uses to indicate on the meter or record the counting rates of the nuclear radiations produced from the atomic reactor or from the radio isotopes. Tte feature of this ratemeter is the use of the transistor chopper for good stabilization. At the input stage of the a. c. amplifier a composite emitter follower buffer stage has been used to give the high input impedance. A hybrid parameter equivalent circuit was modeled for the analysis of this buffer stage. The counting rates can be linearly measured from few CPS up to 100KCPS in 4 ranges. The resolution is less than 0.5$\mu$sec and the output drift at the room temperature with 7-hour continuous operation is in the order of $\pm$0.5$\mu$A.

  • PDF

Development of UWB Sinuous Antenna with Dielectric Lens for 3~6 GHz Band Application (유전체 렌즈를 가진 3~6GHz대용 UWB 시뉴어스 안테나 개발)

  • Lee, Dong Real
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.239-244
    • /
    • 2015
  • Recently, Impulse radars using UWB technologies are widely use for measuring distance, or for transmitting uncompressed high resolution videos. However, since the UWB band spans over octave bands, it is not easy to design such a system. Wide band impedance matching is required for antennas and other RF area. In this study, we designed and fabricated sinuous antenna for 3~6 GHz octave band application. We also designed and attached a dielectric lens to improved the directional gain of the antenna. The gain of the antenna was 6~10 dBi. The dielectric lens attached sinuous antenna was used to transmit HD video data. The maximum reach distance was 90 meter with 10mW power.

NKNLTS 비납계 압전체의 도핑원소에 따른 특성평가

  • Lee, Yun-Gi;Park, Eun-Hye;Ryu, Seong-Rim;Gwon, Sun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.83-83
    • /
    • 2009
  • 우수한 압전성을 가지는 PZT는 인체에 유해한 다량의 PbO을 함유하여 심각한 환경문제를 야기함은 물론 제조 공정 중 PbO 휘발 억제 시설 구비에 따른 경제적 부담 등 문제점이 지적되었다. 따라서 환경오염 및 가격경쟁력을 갖추기 위해 현재 무연 조성 세라믹스에 대한 많은 연구가 진행되고 있다. 최근 비납계 압전 세라믹의 연구는 비스무스 레이어형과 페로브스카이트 형 비납계 세라믹스의 연구가 활발히 진행되고 있다. 특히 $(Na,K)NbO_3$ 계는 페로브스카이트 구조를 가지는 비납계 세라믹으로 현재 많은 연구가 진행되고 있다. 이 물질은 PZT계와 유사하게 상전이(morphotropic phase boundary:MPB)영역을 가지고 있 으며 이 영역에서 높은 압전 특성을 보여주고 있다. 최근 $Na_{0.5}K_{0.5}NbO_3$$LiTaO_3$를 치환하여 우수한 압전 특성을 지니는 조성이 개발되고 있지만, 보통 소성법으로 제조된 세라믹스는 PZT계 세라믹스와 비교하여 특성이 떨어진다. 본 연구에서는 압전성이 우수한 $(Na_{0.44}K_{0.52}Li_{0.44})(Nb_{0.90}Sb_{0.06}Ta_{0.04})O_3$ 조성에 도너 도핑과 억셉터 도핑을 한 다음 전기기계결합계수, 압전상수, 유전상수의 변화를 평가하고, hardener 와 softener 특성이 본조성에서 나타나는지를 관찰하였다. 실험방법은 보통 소성법을 사용하였으며, 분쇄와 혼합은 직경 3 mm zirconia ball을 사용하여 볼밀 하였다. $850^{\circ}C$ 에서 5h 하소 후 $1100{\sim}1200^{\circ}C$ 에서 소결하고, 두께 1 mm로 연마한 다음 silver paste를 $650^{\circ}C$ 에서 소부하여 전극을 형성하였다. 제작된 시편은 $90^{\circ}C$의 실리콘유에서 3~4 kV/mm의 전계를 가해 20분간 분극 처리를 수행하였다. 제작된 시편의 압전전하 상수 값은 d33-meter(APC-8000)를 이용하여 측정하였고, 유전율, 전기기계결합계수 및 기계적품질계수 등은 임피던스 분석기 (impedance/gain phase analyzer)를 이용하여 특성을 측정 하였다. 또한 전압-분극 특성의 평가에는 강유전특성 측정기(ferroelectric tester: Precision-LC, Radiant Technologies, USA)를 이용하였다.

  • PDF