• 제목/요약/키워드: High-Performance mortar

검색결과 189건 처리시간 0.034초

고인성 복합섬유 모르타르를 이용한 플랫 플레이트 구조 슬래브-기둥 접합부의 전단성능 개선 (Improvement of Shear Performance for High Ductile Fiber-Reinforced Mortar Slab-Column Connection in Flat Plate Structural System)

  • 하기주;김윤용;신종학;양승혁;홍건호;김정수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.145-148
    • /
    • 2005
  • Recently the construction of high-rise reinforced concrete building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new structural system is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is with the economy and flexibility, flat plate slab system in high-rise reinforced concrete building. In this research, it was focused in the improvement of shear performance in the flat plate system using high ductile fiber reinforced mortar. It was evaluated the shear performance in the critical region of slab-column connection. The flat plate system, designed by the high performance and safety, was developed as a new technique in the application of high-rise R/C building.

  • PDF

간이 내화시험에 의한 석고계 모르타르의 내화성능 (Fireproof Performance of Mortar using Gypsum in Simplified Heating Test)

  • 강석표
    • 한국건축시공학회지
    • /
    • 제11권2호
    • /
    • pp.181-188
    • /
    • 2011
  • 고강도콘크리트 부재 표면에 내화모르타르를 피복하여 화재시 콘크리트 표층부의 온도상승을 저감시킴으로서 내부 철근온도 상승을 억제한다. 본 논문은 간이내화시험을 통하여 시멘트 및 석고계 내화모르타르 피복 고강도콘크리트의 내부철근 온도상승을 검토하기 위한 것이다. 그 결과 석고계 내화모르타르가 시멘트계 내화모르타르보다 고강도콘크리트의 내부철근 온도상승을 저감시키는데 효과적인 것으로 나타났으며 내화모르타르 피복두께가 작을수록 시멘트계 내화모르타르와의 내부 철근 온도차이가 증가하였다. 또한 ${\alpha}$형 반수석고와 ${\beta}$형 반수석고 종류에 따른 내화모르타르의 온도상승 저감효과의 차이는 없는 것으로 나타났지만, ${\alpha}$형 반수석고 내화모르타르의 압축강도가 ${\beta}$형 반수석고 내화모르타르보다 높게 나타났다.

내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 저항성 평가 (Evaluation of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance)

  • 원종필;최석원;박찬기;박해균
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.559-568
    • /
    • 2006
  • 본 연구의 목적은 화재에 의하여 붕괴 위험성이 있는 터널콘크리트 구조물을 보호하기 위해서 사용하는 습식 고강도 폴리머 스프레이 모르타르의 역학적 특성과 화재저항성을 평가하는 것이다. 본 연구의 주요 목적은 낮은 강도를 가지고 있어 내화재료로서 충분하지 않은 현재 사용되고 있는 재료의 단점을 극복하기 위하여 강도와 화재저항성을 동시에 증가시키는 것이다. 또한 습식 고강도 폴리머 스프레이 모르타르의 피복두께에 따른 내부온도분포를 평가하였으며 화재가 발생하였을 경우 터널콘크리트 구조물을 보호할 수 있는 습식 고강도 폴리머 스프레이 모르타르의 최적두께를 결정하였다. 본 연구의 결과 습식 고강도 폴리머 스프레이 모르타르는 현재 상용화되어 있는 내화용 재료와 비교하여 강도가 높았으며, 우수한 내화성능을 확보하였다. 무엇보다도 화재로부터 기존 구조물을 보호하기 위한 고강도 폴리머 모르타르의 최적 피복두께는 4cm이상 이었다.

폐유리 잔골재가 고강도 모르타르의 역학적 특성 및 알칼리-실리카 반응(ASR), ASR 후, 잔류 역학적 특성에 미치는 영향 (Effect of Waste Glass Fine Aggregate on Mechanical Properites and Alkali-Silica Reaction(ASR), After ASR Residual Mechanical Properties of High Strength Mortar)

  • 유하민;김규용;손민재;사수이;이예찬;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.31-32
    • /
    • 2020
  • This study measured the mechanical performance and residual strength of high strength/normal strength mortar mixed with waste glass fine aggregate after alkali-silica reaction and alkali-silica reaction. As a result, the effect of improving the slip phenomenon of the waste glass fine aggregate in the high-strength mortar was not significant, but rather the amount of ASR was increased.

  • PDF

고인성 모르타르의 내구특성에 관한 실험적 연구 (An Experimental Study on the Durability of High-Ductile Mortar)

  • 노형남;김주상;황남순;김재환;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.71-74
    • /
    • 2007
  • With the changes of times the building materials tend to extend the demand for application under the special environment. Since high-ductile mortar is developed, the building materials show excellent performance like toughness, compression, tensile, and bending, etc. in the general concrete from the existing brittle point. And, recently they are widely used as repairing and reinforcing materials both at home and abroad because they are recognized as excellence like durability and fire-resistance. However, it is in a situation of creating problems in durability because it frequently happened deterioration of buildings that have already repaired and reinforced at a time when it requires reconstruction of recently deteriorated construction structure recently. Therefore, in this study improved with a more repair Material development and reinforcement of the second high-ductile mortar products for a variety of basic materials were presented want, research plans used include traditional repair materials and the newly developed PCM (polymer cement mortar) structural reinforcement type indicated that comparison. PCM analysis in order to present a rate depending on the types fiber 0, 1.2 and 2.0(%) at three levels and mixture water according to ratios of weight to Plain in the 2.0 and 1.85(kg) at two levels is set, the results were as follows. 1) This study has shown that PCM had excellent strain hardening behavior at the same time that the bending stress increased according to the fiber contents. 2) This study has shown that it had the durability performance due to the high substance transmission according to the fiber contents.

  • PDF

혼화재 다량치환 상태에서 FA 및 BS의 혼합비율에 따른 모르타르의 품질특성 (Performance Characteristics of Mortar with High Volume SCM Depending on Combinations of FA and BS)

  • 김민상;송원루;박성배;한동엽;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.126-127
    • /
    • 2016
  • In this research, the optimum combination of fly ash (FA) and blast furnace slag (BS) was deduced by analyzing the performance of high volume supplementary cementitious materials (SCMs) cement mortar depending on various combinations of cement, FA, and BS. As a result, increased workability was shown with increased the portion of FA, while air content, setting time, and compressive strength were decreased.

  • PDF

전기로 산화 슬래그 잔골재 치환율 변화가 석회암 기반 초고강도 모르타르의 기초적 특성에 미치는 영향 (Influence of Various Replacement Ratio of Electric Arc Furnace Fine Aggregate on Fundamental Properties of Limestone Based High Strength Mortar)

  • 문병룡;송원루;이제현;김민상;한인덕;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2016
  • As the demand for super tall buildings is currently increased in domestic and foreign countries, some kinds of ultra-high strength concretes are being developed actively. Since the cross section of concrete becomes smaller thanks to such kinds of ultra-high strength concretes, the concrete structures can be much bigger, more gigantic and much ultra-high. And as another benefit which is generated thanks to the enhancement of the durability performance, the maintenance expenses are also saved. However, since low W/B ultra-high concrete has a high possibility that many cracks can occur in the initial period due to the self-shrinkage caused by the self-desiccation as one of the blending characteristics, the problem becomes bigger by influencing the safety of a structure. Therefore, in this study, it is intended to analyze the effects of substituting some limestone-based ultra-high strength mortar with electric arc furnace oxidizing slag fine aggregates on the self-shrinkage of mortar.

  • PDF

Flexural Behavior of Polymer Mortar Permanent Forms Using Methyl Methacrylate Solution of Waste Expanded Polystyrene

  • Bhutta, M. Aamer Rafique;Tsuruta, Ken;Ohama, Yoshihiko
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권1호
    • /
    • pp.35-39
    • /
    • 2008
  • This experimental study examines the applicability of polymer mortar permanent forms using a methyl methacrylate (MMA) solution of waste expanded polystyrene (EPS) to develop effective recycling processes for the EPS, referring to the flexural behavior of a polymer-impregnated mortar permanent form with almost the same performance as commercial products. An MMA solution of EPS is prepared by dissolving EPS in MMA, and unreinforced and steel fiber-reinforced polymer mortars are mixed using the EPS-MMA-based solution as a liquid resin or binder. Polymer mortar permanent forms (PMPFs) using the EPS-MMA-based polymer mortars without and with steel fiber and crimped wire cloth reinforcements and steel fiber-reinforced polymer-impregnated mortar permanent form (PIMPF) are prepared on trial, and tested for flexural behavior under four-point (third-point) loading. The EPS-MMAbased PMPFs are more ductile than the PIMPF, and have a high load-bearing capacity. Consequently, they can replace PIMPF in practical applications.

팽창재 및 수축저감제가 초고성능 시멘트 모르타르의 수축특성에 미치는 영향 (Effect of Expanding Admixture and Shrinkage Reducing Agent on the Shrinkage Reducing Properties of Ultra High Performance Cement Mortar)

  • 한동엽;유명열;이현수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.61-64
    • /
    • 2006
  • Comparing with traditional high performance concrete, ultra high performance concrete (UHPC) has the property of high-tenacity. However, drying shrinkage and autogenous shrinkage can be arisen as the major defect to UHPC. In this study, therefore, it was tested to reduce drying shrinkage and autogeneous shrinkage by adding expanding admixture (EA) and shrinkage reducing agent (SRA). As a result, for a case drying shrinkage, the shrinkage was decreased by 94% when EA was exchanged, and it was decreased by 64% when SRA was added. For the case of autogenous shrinkage, the mortar was expanded at early age and the shrinkage was decreased by 87% when EA was exchanged, and the shrinkage was decreased by 70% when SRA was added.

  • PDF

고온시에서의 폴리머 시멘트 모르타르의 연소특성에 관한 연구 (Burn-up Characteristics of Polymer-Modified Cement Mortar Used for Building Repair)

  • 김형준;노구치 타카후미
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.295-298
    • /
    • 2012
  • Repair and strengthening is necessary to extend the service life of existing buildings. Polymer-modified cement mortar (PCM) has been extensively used as a high performance material particularly for finishing and repairing works in concrete building because of itsexcellent adhesion, waterproofing, resistance to chemical attack, and workability. As PCM contains organic polymer, it is necessary to clarify its properties at high temperature under fire, on which sufficient data are not available. This paper evaluated the burn-up characteristics of polymer-modified cement mortar with cone calorimeter test, non-combustibility test and flammability test with experimental parameters such as the types of polymer, unit-polymer content, polymer-cement ratio and thickness of the specimen.

  • PDF