• Title/Summary/Keyword: High Voltage DC Transmission

Search Result 95, Processing Time 0.034 seconds

Fabrication and test of a miniaturized superconducting DC cable system (축소형 초전도 직류 케이블 시스템의 제작 및 시험)

  • Kim, Jin-Geun;Kim, Sung-Kyu;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.794-795
    • /
    • 2011
  • The DC side voltage and current of a HVDC transmission system are directly affected by non-linear switching devices such as the thyristor valve which causes real power losses, even under the superconducting conditions of a high temperature superconducting (HTS) power cable. This paper deals with the development of miniaturized superconducting DC cable system. The authors designed and fabricated two thyristor converters for DC transmission system. One is operated as a rectifier and the other is an inverter. The HTS model cable was connected between the DC side of the rectifier and inverter. Real DC transport current and voltage were applied to the miniaturized HTS DC cable. Experimental results are discussed in detail.

  • PDF

The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line (초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발)

  • Ju, Mun-No;Yang, Kwang-Ho;Lee, Dong-Il;Shin, Koo-Yong;Lim, Jae-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

Operational characteristics analysis of a 8 mH class HTS DC reactor for an LCC type HVDC system

  • Kim, S.K.;Go, B.S.;Dinh, M.C.;Kim, J.H.;Park, M.;Yu, I.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.32-35
    • /
    • 2015
  • Many kinds of high temperature superconducting (HTS) devices are being developed due to its several advantages. In particular, the advantages of HTS devices are maximized under the DC condition. A line commutated converter (LCC) type high voltage direct current (HVDC) transmission system requires large capacity of DC reactors to protect the converters from faults. However, conventional DC reactor made of copper causes a lot of electrical losses. Thus, it is being attempted to apply the HTS DC reactor to an HVDC transmission system. The authors have developed a 8 mH class HTS DC reactor and a model-sized LCC type HVDC system. The HTS DC reactor was operated to analyze its operational characteristics in connection with the HVDC system. The voltage at both ends of the HTS DC reactor was measured to investigate the stability of the reactor. The voltages and currents at the AC and DC side of the system were measured to confirm the influence of the HTS DC reactor on the system. Two 5 mH copper DC reactors were connected to the HVDC system and investigated to compare the operational characteristics. In this paper, the operational characteristics of the HVDC system with the HTS DC reactor according to firing angle are described. The voltage and current characteristics of the system according to the types of DC reactors and harmonic characteristics are analyzed. Through the results, the applicability of an HTS DC reactor in an HVDC system is confirmed.

Rectifier Design Using Distributed Greinacher Voltage Multiplier for High Frequency Wireless Power Transmission

  • Park, Joonwoo;Kim, Youngsub;Yoon, Young Joong;So, Joonho;Shin, Jinwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • This paper discusses the design of a high frequency Greinacher voltage multiplier as rectifier; it has a greater conversion efficiency and higher output direct current (DC) voltage at high power compared to a simple halfwave rectifier. Multiple diodes in the Greinacher voltage multiplier with distributed circuits consume excited power to the rectifier equally, thereby increasing the overall power capacity of the rectifier system. The proposed rectifiers are a Greinacher voltage doubler and a Greinacher voltage quadrupler, which consist of only diodes and distributed circuits for high frequency applications. For each rectifier, the RF-to-DC conversion efficiency and output DC voltage for each input power and load resistance are analyzed for the maximum conversion efficiency. The input power with maximum conversion efficiency of the designed Greinacher voltage doubler and quadrupler is 3 and 7 dB higher, respectively;than that of the halfwave rectifier.

Optimization of DC Operating Voltage for GDT-Adopted SPD (가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

Clamping-diode Circuit for Marine Controlled-source Electromagnetic Transmitters

  • Song, Hongxi;Zhang, Yiming;Gao, Junxia;Zhang, Yu;Feng, Xinyue
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.395-406
    • /
    • 2018
  • Marine controlled-source electromagnetic transmitters (MCSETs) are important in marine electromagnetic exploration systems. They play a crucial role in the exploration of solid mineral resources, marine oil, and gas and in marine engineering evaluation. A DC-DC controlled-source circuit is typically used in traditional MCSETs, but using this circuit in MCSETs causes several problems, such as large voltage ringing of the high-frequency diode, heating of the insulated-gate bipolar transistor (IGBT) module, high temperature of the high-frequency transformer, loss of the duty cycle, and low transmission efficiency of the controlled-source circuit. This paper presents a clamping-diode circuit for MCSET (CDC-MCSET). Clamping diodes are added to the controlled-source circuit to reduce the loss of the duty ratio and the voltage peak of the high-frequency diode. The temperature of the high-frequency diode, IGBT module, and transformer is decreased, and the service life of these devices is prolonged. The power transmission efficiency of the controlled-source circuit is also improved. Saber simulation and a 20 KW MCSET are used to verify the correctness and effectiveness of the proposed CDC-MCSET.

Design and Fabrication of RF-DC Converters for 5.8 GHz Microwave Wireless Power Transmission (5.8 GHz 마이크로파 무선전력전송을 위한 RF-DC 변환기의 설계 및 구현)

  • Lee, Seong Hun;Son, Myung Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.84-87
    • /
    • 2015
  • We have designed and fabricated two different RF-DC Converters called doubler for 5.8GHz Microwave Wireless Power Transmission. The doubler as RF-DC Converter makes the rectified voltage be doubled. We measured and compared voltages of the doublers with those of the previous full-wave rectifying RF-DC Converter. The doublers show rectified double voltages. However, the full-wave rectifying converter has a high efficiency due to the suppression of reflecting harmonics. The other fabricated doublers causes so many harmonics that they can't convert the low-power RF to the full DC. In this paper, we show that the different doublers doesn't double the rectifying voltages compared with those of the full-wave rectifying converter and give a reason about that.

Device Feature and Application Status for Light Triggering Thyristor(LTT) in HVDC Transmission (HVDC 송전용 광구동 사이리스터(LTT)를 위한 소자특성 및 응용의 요구)

  • Zhang, C.L.;Kim, S.C.;Kim, E.D.;Kim, H.W.;Seo, K.S.;Bhang, W.;Cheong, K.Y.;Kim, N.K.;Luo, J.Q.;Bai, J.B.;Wang, X.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.397-400
    • /
    • 2004
  • The design concept for 8kV light triggering thyristor(LTT) with integrated BOD was discussed here in detail. The trade-off between light triggering input source againsthigh dV/dt limitation has been treated via grooved P-base for gate design. The main application point used for high voltage DC transmission(HVDC) was represented.

  • PDF

A distance Relaying Algorithm Based on Numerical Solution of a Differential Equation for Transmission Line Protection (송전선 보호용 적분근사 거리계전 알고리즘)

  • 조경래;정병태;홍준희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.5
    • /
    • pp.711-720
    • /
    • 1994
  • A distance relaying algorithm for detecting faults at power transmission line is presented in this paper. The algorithm is based on differential equation from relaton between voltage and current, which is composed of lumped resistance and inductance. During the fault transient state,the voltage and current signals are severely distorted due to the exponentially decaying DC offset and high frequency components, In spite of using small data, the presented integral method to evaluate R and L from voltage and current has high performance against these harmonics including DC offset. Therefore, the presented algorithm can be implemented with only a low order anti-aliasing analog filter and dosen't need any digital filter to remove specific components.

  • PDF

Switching Frequency Reduction Method for Modular Multi-level Converter Utilizing Redundancy Sub-module (예비 서브모듈을 활용한 모듈형 멀티레벨 컨버터의 스위칭 주파수 저감 기법)

  • Lee, Yoon-Seok;Yoo, Seung-Hwan;Choi, Jong-Yun;Park, Yong-Hee;Han, Byung-Moon;Yoon, Young-Doo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1640-1648
    • /
    • 2014
  • This paper proposes a switching frequency reduction method for MMC (Modular Multilevel Converter) utilizing redundancy operation of sub-module, which can offer reduction of voltage harmonics and switching loss. The feasibility of proposed method was verified through computer simulations with PSCAD/EMTDC software. Based on simulation analysis, a hardware scaled-model of 10kVA, DC-1000V MMC was designed and manufactured in the lab. Various experiments were conducted to verify the feasibility of proposed method in the actual hardware system. The hardware scaled-model can be effectively utilized for analyzing the performance of MMC according to the modulation scheme and redundancy operation.