• 제목/요약/키워드: Generator protection system

검색결과 160건 처리시간 0.033초

IEMI 복사에 의한 네트워크 통신 장비의 취약성 분석 (Vulnerability Analysis of Network Communication Device by Intentional Electromagnetic Interference Radiation)

  • 서창수;허창수;이성우;진인영
    • 한국전기전자재료학회논문지
    • /
    • 제31권1호
    • /
    • pp.44-49
    • /
    • 2018
  • This study analyzed the Vulnerability of Network Communication devices when IEMI is coupled with the Network System. An Ultra Wide Band Generator (180 kV, 700 MHz) was used as the IEMI source. The EUTs are the Switch Hub and Workstation, which are used to configure the network system. The network system was monitored through the LAN system configuration, to confirm a malfunction of the network device. The results of the experiment indicate that a malfunction of the network occurs as the electric field increases. The data loss rate increases proportionally with increasing radiating time. In the case of the Switch Hub, the threshold electric field value was 10 kV/m for all conditions used in this experiment. The threshold point causing malfunction was influenced only by the electric field value. The correlation between the threshold point and pulse repetition rate was not found. However, in case of the Workstation, it was found that as the pulse repetition rate increases, the equipment responds weakly and the threshold value decreases. To verify the electrical coupling of the EUT by IEMI, current sensors were used to measure the PCB line inside the EUT and network line coupling current. As a result of the measurement, it can be inferred that when the coupling current due to IEMI exceeds the threshold value, it flows through the internal equipment line, causing a malfunction and subsequent failure. The results of this study can be applied to basic data for equipment protection, and effect analysis of intentional electromagnetic interference.

기존 선박의 디젤발전기용 SCR 시스템 설치에 관한 연구 (A Study on the Installation of SCR System for Generator Diesel Engine of Existing Ship)

  • 류영현;김홍렬;조규백;김홍석;남정길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.412-417
    • /
    • 2015
  • IMO MEPC에서는 해양환경 보호를 위해서 선박으로부터 배출되는 배기가스 규제를 날로 점점 강화하고 있다. 특히, 2016년부터 건조되어 국제항해를 하는 모든 신조 선박에 대한 질소산화물(NOx) 배출량은 Tier-III 규제를 만족하게 되어 있다. 본 연구에서는 선박용으로 개발된 NOx 저감용 SCR(선택적 환원 촉매) 시스템을 기존 선박의 디젤발전기에 설치하여 NOx 저감성능을 파악하고자 하였다. 본 연구를 위하여 목포해양대학교 실습선 새누리호 디젤발전기의 배기 파이프라인을 개조 공사하여 요소 SCR 시스템을 설치하였으며, 요소 용액(40%) 분사 방법은 수동 모드와 PLC를 통한 자동 모드로 나누어 두 가지 방법으로 실험을 하였다. 수동 모드 방법을 통하여 암모니아 슬립 발생구간을 찾을 수 있었으며, 엔진부하별(25, 35 및 50%)로 최적의 요소 분사량을 조절할 수 있었다. 부하를 Down-Up(25%에서 50%로 올리면서) 시보다도 Up-Down(50%에서 25%로 내리면서) 시에 NOx 저감성능이 더 좋음을 알 수 있었으며, 본 바나듐계 촉매가 사용된 SCR 시스템을 기존 선박의 디젤발전기에 설치하여 질소산화물이 80% 이상 절감됨을 확인할 수 있었다.

발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석 (Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type)

  • 최준호;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권4호
    • /
    • pp.23-30
    • /
    • 2000
  • 열병합발전 시스템은 환경 친화적인 동시에 상대적으로 고 효율의 에너지 시스템으로서 분산 방전설비의 혁신 기술중 하나이다, 아울러 열병합발전 시스템운 열과 전기의 분산공급에 적절한 발전 시스템이다. 그러나, 열병합발전 시스템의 계통 연계는 전압 소정, 전압변동, 보호협조, 안전등의 제반 연제문제를 수반한다. 특히, 이러한 연계문제 중 열병합발전 시스템의 배전계통 연계.분리 운전은 배전계통의 전압조정 및 변동에 영향을 미칠 것이 예상된다. 최근 수용가 소유의 컴퓨터 및 민감한 전자소자의 사용 증가로 인하여 전력품질온 중요한 고려사항이 되고 있다. 따라서 열병합발전 시스템과 관련한 전압품질은 반드시 분석되어야만 한다. 왜냐하면 전압품질은 전력 품질의 중요한 요소이기 때문이다. 본 논문에서는 열병합발전 시스템의 배전계통 연계 운전에 따른 순서전압변통 에 대하여 컴퓨터 시물레이션을 롱하여 분석하였고、 또한 이의 억제 대책을 제시하였다. 아울러 순시전압변동 측면에서 본 피더 당 열병합발전시스템의 단위 도입 용량을 평가하였다. 본 논문의 결과는 열병합발전 시스템 또는 분산형 전원의 계통 연계 표준. 가이드라인에 유용한 자료가 되리라 믿는다.

  • PDF

Dedicated Cutback Control of a Wind Power Plant Based on the Ratio of Command Power to Available Power

  • Thapa, Khagendra;Yoon, Gihwan;Lee, Sang Ho;Suh, Yongsug;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.835-842
    • /
    • 2014
  • Cutback control in a grid code is one of the functions of a wind power plant (WPP) that is required to support the system protection and frequency stability. When a cutback control command signal is delivered to the WPP from the system operator, the output of a WPP should be decreased to 20% of the rated power within 5 s. In this paper, we propose a dedicated cutback control algorithm of a WPP based on the ratio of the command power to the available power. If a cutback control signal is delivered, the algorithm determines the pitch angle for the cutback control and starts the pitch angle control. The proposed algorithm keeps the rotor speed at the speed before the start of the cutback control to quickly recover the previous output prior to the cutback control. The performance of the algorithm was validated for a 100 MW aggregated WPP based on a permanent magnet synchronous generator under various wind conditions using an EMTP-RV simulator. The results clearly shows that the proposed algorithm not only successfully reduces the output to the command power within 5 s by minimizing the fluctuation of the pitch angle, but also rapidly recovers to the output level before the cutback control.

광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과 (Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water)

  • 최재혁;김다운;정규석;노은정;류경열;류재기
    • 한국식품위생안전성학회지
    • /
    • 제34권6호
    • /
    • pp.583-590
    • /
    • 2019
  • 본 연구는 기존 기초 연구를 통해 효과가 확인된 '광에너지유도 활성산소'를 이용하여 세척용수를 소독할 수 있는 신개념의 순환형 물 소독 시스템에 대해 실증하는 것이다. 다양한 형태의 감광제 이용 광유도 ROS 발생장치를 이용하여 여러 종류의 병원성 세균을 1시간안에 3 log CFU/mL 이상의 밀도를 감소시키는 조건을 탐구하였다. PS-bead이용 광유도 ROS 발생장치의 밀도 감소 효과에 미치는 주요 요인을 분석한 결과, 세균의 종류에 따라 ROS에 대한 밀도 감소효과가 서로 상이 하였다. B. cereus와 P. carotovorum subsp. carotovorum에 대한 밀도 감소효과는 높았으나 대장균 등 식중독 세균들에 대한 밀도 감소 효과는 상대적으로 낮았다. 순환형 물 소독시스템에서 유속은 유속이 빨라질 수록, 초기 세균밀도가 낮을수록 밀도 감소효과가 증가하는 경향을 보였다. bead의 양이 증가함에 따라 밀도 감소 효과는 일부 대상세균에서 지수적으로 증가함을 알 수 있었다. 싱글 유닛 두 개를 연결한 더블원통유닛3280은 B. cereus 나 P. carotovorum subsp. carotovorum에 대한 실험에서 30 분 안에 약 3 log CFU/mL 이상의 균을 완전히 살균할 수 있었다.

LFG Utilization in Hong Kong (Case study of the Shuen Wan and Urban Landfills)

  • Lloyd, Bryce;Chan, Louis;Nardelli, Ray;Sullivan, Kevin
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 2001년도 정기총회 특별강연 및 춘계학술연구발표회(2)
    • /
    • pp.85-91
    • /
    • 2001
  • This paper provides a case study of landfill gas (LFG) utilization fer direct use as process fuel, and for electrical power generation at restored landfills in the Hong Kong Special Administrative Region of China (HKSAR). The paper specifically covers the LFG utilization schemes, which are required under landfill restoration contracts at the Shuen Wan and Urban Landfills. These contracts provide for the restoration and aftercare of six landfills, and are administered by the Environmental Protection Department (EPD) of the Hong Kong Government. The LFG utilization scheme at the Shuen Wan Landfill incorporates the direct use of LFG by compressing and dehumidifying the LFG prior to conveyance through a 1.6-kilometer (1-mile) pipeline. The pipeline provides an alternate fuel source to naphtha during process heating for gas production at the Tai Po Gas Production Plant of the Hong Kong and China Gas Limited (HKCC). The LFG utilization scheme at the Jordan Valley Landfill (one of the Urban Landfills) beneficially uses the LFG as fuel for electrical power generation with reciprocating internal combustion engines. The LFG is compressed, cooled, and filtered prior to delivery to two engine/generator sets. This system provides power to operate the leachate pre-treatment plant, which processes leachate from all of the Urban Landfill sites. The case study will examine the technical and non-technical considerations, including harriers, for developing, designing and implementing the LFG utilization projects in Hong Kong. Specific regulatory considerations and external governmental agency approvals are discussed, including the requirement to register as a gas-producing utility. While the paper focuses on LFG utilization applications in Hong Kong, many of the considerations discussed are also applicable to development of LFG utilization in other regions of Asia.

  • PDF

22.9kV 지중선로용 한류기 한전 실계통 시범적용 (Application of Fault Current Limiter in 22.9kV KEPCO power distribution line)

  • 김민지;박경원;안길영;김영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

  • Na Hye Kwon;Hye Sung Park;Taehwan Kim;Sang Rok Kim;Kum Bae Kim;Jin Sung Kim;Sang Hyoun Choi;Dong Wook Kim
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.53-62
    • /
    • 2022
  • In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities using radiation generators. And we investigated the current status of shielding evaluation of domestic industrial radiation generators. According to the statistical data from the Radiation Safety Information System, as of 2022, a total of 7,679 organizations are using radiation generating devices. Among them, 6,299 facilities use these devices for industrial purposes, which accounts for a considerable portion of radiation. The organizations that use these devices evaluate whether the exposure dose for workers and frequent visitors is suitable as per the limit regulated by the Nuclear Safety Act. Moreover, during this process, the safety shields are evaluated at the facilities that use the radiation generating devices. However, the facilities that use radiating devices having energy less than or equal to 6 MV for industrial purposes are still mostly evaluated and analyzed according to the National Council on Radiation Protection and Measurements 49 (NCRP 49) report published in 1976. We have investigated the technical standards of safety management, including the maximum permissible dose and parameters assessment criteria for facilities using radiation generating devices, based on the NCRP 49 and the American National Standards Institute/Health Physics Society N.43.3 reports, which are the representative reports related to radiation shielding management cases overseas.

가압 경수로 및 가압중수로형 원자력 발전소의 중대사고 리스크 비교 평가 (A Comparison Study on Severe Accident Risks Between PWR and PHWR Plants)

  • 정종태;김태운;하재주
    • Journal of Radiation Protection and Research
    • /
    • 제29권3호
    • /
    • pp.187-196
    • /
    • 2004
  • 경수로형인 한국형 표준원전과 CANDU형 중수로형 원자력 발전소의 가상 중대사고시 대기 중으로 방출되는 방사성 물질로 인한 인체 건강영향에 미치는 리스크를 평가하고 비교하였다. 두 발전소 모두 반경 80km 까지의 인구분포와 2단계 PSA의 결과로 주어지는 방사선원 방출군별 방출 분율과 노심 재고량을 이용하였으며 평가 도구로는 MACCS2를 이용하였다. 인체에 미치는 영향은 조기 사망과 암 사망을 선정하였으며 반경 10 마일 밖으로 소개가 이루어진다고 가정하고 평가 결과는 사고 발생빈도를 고려한 리스크를 CCDF 곡선군으로 나타냈다. 평가 결과에 의하면 경수로형 원전에 비해 중수로형 원전이 리스크가 적게 나타나는데 이는 중수로형 원전이 경수로형 원전에 비해 가상 중대사고로 인해 대기 중으로 방출되는 방사성 물질의 양이 적기 때문이다. 두 발전소 모두 최대 리스크를 보이는 방사선원 방출군의 대표적인 초기사건은 증기발생기 세관파손 사고로 나타났다. 따라서, 경수로형 및 중수로형 발전소 모두 사고로 인한 주변 주민 보호를 위해서는 증기발생기 세관파손 사고의 발생빈도와 이로 인한 대기 중으로의 방사성 물질의 방출을 감소시키기 위한 방안이 강구되어야 한다.

유통중 청과물의 진동 특성 연구 (I) - 실험적 해석에 의한 배의 진동특성 - (Vibration Characteristics of the Fruit and Vegetables during Transportation (I) - Vibration Charateristics of the Pear by Experimental Analysis -)

  • 김만수;정현모;김기석;박정길
    • 농업과학연구
    • /
    • 제30권2호
    • /
    • pp.175-183
    • /
    • 2003
  • 본 연구에서는 청과물 포장설계시 중요한 자료가 되는 청과물의 공진 주파수 및 정점가속도 등의 진동특성을 분석하기 위하여 실험적 방법을 적용하였으며, 그 결과를 요약하면 다음과 같다. 1. 청과물의 진동특성을 분석할 수 있는 실험장치를 구성하였으며, 장치의 제어와 계측을 위한 컴퓨터 프로그램을 개발하였다. 2. 공시된 배의 공진 주파수는 약 64.5~72.2Hz 범위이었으며, 정점가속도는 약 1.78~2.21G-rms 범위이었다. 3. 공시된 배의 공진 주파수 및 정점 가속도는 배의 질량과 체적이 증가함에 따라 감소하는 것으로 판단되었다. 4. 배의 공진 주파수 및 정점 가속도와 기계적 특성들간에는 생물체항복변형량(BD) 및 극한변형량(RD)을 제외하고는 상관관계가 매우 낮은 것으로 분석되었다. 5. 본 실험의 목적은 과실의 공진 주파수를 구명하는 것으로 이 결과는 배의 운송 시 차량의 입력주파수와 배의 공진 주파수가 일치되어 공진으로 급격하게 가속도가 증가되는 것을 방지함으로써 충격에 의한 손상을 줄이는데 활용될 수 있을 것이다.

  • PDF