발전소의 발전기 보호계전시스템 (Generator Protection Relaying System in Power Plant)

  • 안준영;박철원;이종수;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.151-152
    • /
    • 2006
  • Because power plant faults have severe effects on the power system and on mechanical maintenance of the generator, reliable protection systems are needed. In this paper, we compared and analyzed methods of the generator protection relaying system, which can defect internal faults of the generator, and surveyed the trends in generator protection using digital computing.

  • PDF

345kV 계통 모델링 데이터를 활용한 과여자 보호계전기법 (Over-Excitation Protection Relaying using the 345kV Power System Modeling Data)

  • 박철원;반우현
    • 전기학회논문지P
    • /
    • 제60권4호
    • /
    • pp.175-180
    • /
    • 2011
  • A large AC generator is an important component of the power system. It is a need for research of AC generator protection relay for the next-generation ECMS and an efficient operation of protection control system. However, most of protection and control systems used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, over-excitation protection relaying is one of the protective factors in generator protection IED was presented. The cause and protection principles were dealt and, DFT-based gain compensation algorithm was adopted for the frequency measurement. The Republic of Korea 345kV modeling data by EMTP-RV was used for performance evaluation.

수력 발전기 제어시스템의 계자상실 모델링과 시뮬레이션 (Modeling and Simulation of Loss of Excitation of Hydro Generator Control System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.74-80
    • /
    • 2014
  • Generator protection device has to detects an internal fault conditions in generator and abnormal operating conditions must be due to the hazards. Loss of excitation may cause generator itself failure as well as serious operating problem in power system, and then requires an appropriate response of generator protection device. Details modeling of generator control system and analysis of transient states in generator are important for optimal operation in power plants. In addition, the fault simulation data are also used for testing the characteristics of IED. In this paper, the hydro generator control system using PSCAD/EMTDC, visual simulation for power systems, was modeled. The generator control system which is composed of generator, turbine, exciter, governor was implemented. The parameters of generator control system model were obtained from field power plant. Loss of excitation simulations were performed while varying the fixed load. Several signals analysis were also performed so as to analyze transients phenomena.

대용량 발전기보호를 위한 발전기 모델링 (Generator System Modeling for Large Generator Protection)

  • 박철원;안준영;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.121-122
    • /
    • 2006
  • The generator system modeling for large generator protection is a significant portion for the analysis of installed apparatus and development of domestic production. In this paper, MATLAB EMTP/ATP, and PSCAD/EMTDC are used to simulate the transient phenomenon for the faults of generator.

  • PDF

발전기 과도현상에 따른 발전기 보호 계전기 동작 분석 (An Analysis of Protection Relay Operation During Transient Sate of Generator)

  • 권영진;강상희;김철훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.378-380
    • /
    • 2006
  • Loss of excitation, over excitation and motoring of generator are simulated by using synchronous generator with an exciter and a governor. This paper presents an analysis of transient state of generator and protection relay operation with loss of excitation. over excitation and motoring of generator.

  • PDF

스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발 (Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator)

  • 이종훤
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

Emergency Brushless Synchronous Generator Having Rotating Exciter Status Monitoring and Protection Functions

  • Oh, Yongseung;Oh, Wonseok;Cho, Kyumin
    • 한국정보기술학회 영문논문지
    • /
    • 제10권2호
    • /
    • pp.1-13
    • /
    • 2020
  • This paper presents an emergency brushless synchronous generator having rotating exciter status monitoring and protection functions. For monitoring the rotating exciter status, a wireless rotor status detector and a digital AVR(Automatic Voltage Regulator), which has a wireless communication capability, are proposed. The proposed rotor status detector detects temperatures of exciter armature and main field windings and input voltage and current of the main field. Therefore, it is possible to protect the generator from the over-temperature of windings and detect the exciter bridge diode fault. Furthermore, the proposed digital AVR has rotor status monitoring and protection function, and remote generator tuning, wireless group parallel operation function. So the operator can efficiently operate the generator using a smartphone from a remote area.

ATPDraw5.7p4 모델링 데이터를 이용한 전압억제 과전류계전기 동작특성에 관한 연구 (A Study of the Operating Characteristic for Voltage Restrained Overcurrent Relay using the ATPDraw5.7p4 Modeling Data)

  • 박철원;반우현
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.23-28
    • /
    • 2012
  • The market of domestic Power Plant Generator Protection and Control System (GPCS) is narrow and required the high reliability, and technology. So, it is still operated as turn-key. In recent years, digital relays has evolved into IED can perform the control and monitoring functions without central monitoring based on IEC61850 international standards communications, and attention for advancement of smart grid and ECMS has been increased in South Korea. The increasing attention on multi-function IED, DGPS(digital generator protection system), for internal fault protection of large generator results in starting a national project in South Korea, the IED prototype development for next-generation power units. The voltage restrained overcurrent relay have been used as back-up overcurrent protection for generators. In this paper, voltage restrained overcurrent relay is one of the back-up protective factors in generator protection IED was presented. For evaluation performance of the voltage restrained overcurrent relay, the data of ATPDraw5.7p4 modeling was used.

A Study on the Detection of Asynchronous State of the Synchronous Generator

  • Choi, Hyung-Joo;Lee, Heung-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.405-412
    • /
    • 2013
  • This paper includes new protection concepts and practices to avoid mechanical damage of three-phase transformer by asynchronous operation of synchronous generator. this failure is often caused just after synchronous generator was connected to the grid because of a malfunction of the controller or misconnections of the synchronous devices. The results of the studies on the analyzing the phenomenon of asynchronous operation experienced in Korea and rapidly detecting asynchronous state are descrived.

Impact of Fixed Series Capacitors and SSSC on the LOE Protection of Synchronous Generator

  • Ghorbani, Amir;Lima, Hossein Mehryari;Azadru, Allahverdi;Mozafari, Babak
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1453-1459
    • /
    • 2015
  • Loss of excitation (LOE) relay is prevalently used to protect synchronous generator. The widely used method for synchronous generator LOE protection is a negative offset mho relay with two zones. The basis of this relay is identical to mho impedance relay. In other words, this relay calculates impedance by measuring voltage and current at the generator terminal. On the other hand, the presence of series compensation, changes measured voltage and current signals during loss of excitation. This paper reveals that the presence of series compensators such as fixed series capacitors (FSCs) and static synchronous series compensator (SSSC) causes a significant delay on the performance of generator LOE relay. It is also shown that the presence of SSSC causes the LOE relay to be under-reached. Different operating modes of the power system, the SSSC and also different percentages of series capacitive compensations have been considered in the modeling. All the detailed simulations are carried out in the MATLAB/Simulink environment using the SimPowerSystems toolbox.