• Title/Summary/Keyword: Fuel-cut

Search Result 119, Processing Time 0.028 seconds

The Assessment and Reduction Plan of Radiation Exposure During Decommissioning of the Steam Generator in Kori Unit 1 (고리1호기 증기발생기 제염해체 시 작업자 피폭선량 평가 및 저감화 방안)

  • Son, Young Jik;Park, Sang June;Byon, Jihyang;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.377-387
    • /
    • 2018
  • Korea's first commercial nuclear power plant, Kori Unit 1, was permanently shut down on June 18, 2017, after 40 years of successful operation. Kori Unit 1 plans to construct a waste treatment facility in the turbine building prior to commencement of dismantling in earnest. Various radioactive wastes are decontaminated, disassembled, cut and melted in the waste treatment facility and sent to the radioactive waste repository. The proportion of metal radioactive waste in dismantled waste is about 70%, of which large metal radioactive waste is mainly generated in the primary circuit and has high radioactivity, so radiation exposure must be managed during disassembly. In this study, the steam generators are selected as large metal radioactive waste, the exposure doses of the dismantling workers are calculated using RESRAD-RECYCLE code and the methods for reducing the exposure doses are suggested.

Preparation of Refuse-Derived-Fuel from Automobile Shredder Residues (폐자동차 파쇄 잔류물을 이용한 고분연료의 제조연구)

  • Lee Hwa-Yaung;Oh Jong-Kee;Kim Sung-Gyu
    • Resources Recycling
    • /
    • v.12 no.4
    • /
    • pp.58-64
    • /
    • 2003
  • A study on the preparation of RDF with ASR materials from shredder line of end-of-life vehicles has been peformed by using hot molding method. ASR materials used in the work were plastics, fibers and sponge which were cut by less than 10 mm in size prior to hot molding and 40, 60 and 80 mm mold in diameter were employed for RDF forming. It was found that heating temperature, heating time and mixing ratio of materials played an important role in the hot molding of ASR materials. Density of RDF samples Prepared in the work was in the range of 0.5∼0.9gr/ml depending on the hot molding conditions and it was decreased with increase in the content of sponge. Breaking strength of RDF samples was observed to 0.8∼3.0MPa and it was also increased with increase in density of RDF samples. Finally, when heating temperature was elevated, density of RDF was increased due to Increase in molten part of ASR materials which resulted in the enhancement of breaking strength of RDF.

Experimental Study on Transient Response According to Variation of Rib Height at Fuel Cell Plate (연료전지용 분리판의 리브 높이 변화에 따른 응답성 변화에 관한 실험적 연구)

  • Nam, Ki Hoon;Yun, Sung Ho;Han, Sung Ho;Choi, Nam Hyeon;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1009-1014
    • /
    • 2013
  • In the present study, using a variation of rib height, the transient response and the performance are investigated. The cell voltage is acquired according to the current density change($0.8A/cm^2$ to $1.0A/cm^2$) under same stoichiometry and relative humidity. The different level of undershoots appeared at the different clamping pressure(1.5MPa and 2.0MPa) and different rib height. At 1.5MPa clamping pressure, rib manufactured cut at $100{\mu}m$ height goes to steady state faster than reference plate and has lower maximum undershoot voltage. But performance is lower than reference plate due to increasing contact resistance.

Evaluation on Radioactive Waste Disposal Amount of Kori Unit 1 Reactor Vessel Considering Cutting and Packaging Methods (고리 1호기 원자로 압력용기 절단과 포장 방법에 따른 처분 물량 산정)

  • Choi, Yujeong;Lee, Seong-Cheol;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.2
    • /
    • pp.123-134
    • /
    • 2016
  • Decommissioning of nuclear power plants has become a big issue in South Korea as some of the nuclear power plants in operation including Kori unit 1 and Wolsung unit 1 are getting old. Recently, Wolsung unit 1 received permission to continue operation while Kori unit 1 will shut down permanently in June 2017. With the consideration of segmentation method and disposal containers, this paper evaluated final disposal amount of radioactive waste generated from decommissioning of the reactor pressure vessel in Kori unit 1 which will be decommissioned as the first in South Korea. The evaluation results indicated that the final disposal amount from the top and bottom heads of the reactor pressure vessel with hemisphere shape decreased as they were cut in smaller more effectively than the cylindrical part of the reactor pressure vessel. It was also investigated that 200 L and 320 L radioactive waste disposal containers used in Kyung-Ju disposal facility had low payload efficiency because of loading weight limitation.

Studies on the Focusing Solar Agricultural Crop Dryer - II. Aluminum-laminated Acryl Film Cylindrical Focusing Solar Food Dryer - (농산물(農産物) 건조용(乾燥用) 곡면(曲面) 집광식(集光式) 태양(太陽) 열(熱) 이용(利用) 장치(裝置)에 관한 연구 - 제(第) 2 보(報) : 알루미늄-아크릴 필름 태양열(太陽熱) 이용(利用) 장치를 사용한 농산물(農産物) 건조(乾燥)에 관한 연구 -)

  • Chun, Jae-Kun;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.258-263
    • /
    • 1979
  • A cylindrical focusing solar food dryer made with aluminum-laminated acryl film was demonstrated for the dehydration of agricultural product and its perfomance was analyzed with respect to the solar energy utilization and its scale-up technology. With one square meter reflector and a 74 cm copper pipe absorber, the heat exchange efficiency between air stream and absorber was 1.39 %. The installation of circular segment-baffle increased 33 % of the efficiency. In dehydration of radish-cut with this drier, 58 % of fuel consumption was saved. The relationship between reflector area and heat energy utilization was established for the scale-up purpose.

  • PDF

Feasibility Study of Cryogenic Cutting Technology by Using a Computer Simulation and Manufacture of Main Components for Cryogenic Cutting System (컴퓨터 시뮬레이션을 이용한 극저온 절단 기술 적용성 연구 및 극저온 절단 시스템 주요 부품 제작)

  • Kim, Sung-Kyun;Lee, Dong-Gyu;Lee, Kune-Woo;Song, Oh-Seop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.115-124
    • /
    • 2009
  • Cryogenic cutting technology is one of the most suitable technologies for dismantling nuclear facilities due to the fact that a secondary waste is not generated during the cutting process. In this paper, the feasibility of cryogenic cutting technology was investigated by using a computer simulation. In the computer simulation, a hybrid method combined with the SPH (smoothed particle hydrodynamics) method and the FE (finite element) method was used. And also, a penetration depth equation, for the design of the cryogenic cutting system, was used and the design variables and operation conditions to cut a 10 mm thickness for steel were determined. Finally, the main components of the cryogenic cutting system were manufactures on the basis of the obtained design variables and operation conditions.

  • PDF

A Case Study of Spatial Allocation of Cut Blocks Using a Timber Harvest Simulator HARVEST (산림수확 시뮬레이터 HARVEST 응용에 의한 벌채지 공간배치 사례연구)

  • Song, Jungeun;Jang, Kwangmin;Han, Hee;Seol, Ara;Chung, Woodam;Chung, Joosang
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.96-103
    • /
    • 2012
  • In this study, we used HARVEST, a timber management strategy assessment tool, to evaluate alternative forest planning strategies on spatial pattern of cutting blocks. We applied the tool to the Gwangreung Experimental Forest (GEF) as a case study. The harvest schedules developed for GEF using a linear programming model was used to assess spatial patterns of cutting blocks under different management constraints. The results show that the allowable maximum harvest size largely affects the number, size, and distribution of cutting blocks. We also found that spatial dispersion methods and adjacency constraints could be used as an effective means to control spatial allocation of cutting blocks in order to meet certain forest ecosystem management goals.

A Study on the Composition of Atkinson Cycle and Thermodynamically Analysis for a Diesel Engine (디젤기관에 대한 앳킨슨사이클 구성과 사이클의 열역학적 해석에 관한 연구)

  • Kim Chul Soo;Jung Young Guan;Jang Tae lk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.2
    • /
    • pp.185-193
    • /
    • 2005
  • The present study composed a diesel-atkinson cycle of high expansion as a method of achieving high efficiency in diesel cycle engines. It also interpreted the cycle engine thermodynamically analysis to determine the possibility of the improvement of thermal efficiency and clarified the characteristics of several factors . According to the result of theoretical analysis, heat efficiency was highest when expansion-compression ratio Reど:1. In addition. diesel engines with high apparent compression ratio had higher expansion-compression ratio than otto engines and consequently their effect of high expansion was high. which in turn enhanced thermal efficiency. When the atkinson cycle was implemented in a real diesel engine by applying the miller cycle through the variation of the closing time of the intake valve, the effective compression ratio and the quantify of intake air decreased and as a result, the effect of high expansion was not observed. Accordingly. the atkinson cycle can be implemented when the quantity of intake air is compensated by supercharge and the effective compression ratio is maintained at its initial level through the reduction of the clearance volume. In this case. heat efficiency increased by $4.1\%$ at the same expansion-compression ratio when the apparent compression ratio was 20 and the fuel cut off ratio was 2. As explained above, when the atkinson cycle was used for diesel cycle. heat efficiency was improved. In order to realize high expansion through retarding the intake value closing time, the engine needs to be equipped with variable valve timing equipment, variable compression ratio equipment and supercharged Pressure equipment. Then a diesel-atkinson cycle engine is realized.

Lateral Resistance of CLT Wall Panels Composed of Square Timber Larch Core and Plywood Cross Bands

  • JANG, Sang Sik;LEE, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.547-556
    • /
    • 2019
  • Thinned, small larch logs have small diameters and no value-added final use, except as wood chips, pallets, or fuel wood, which are products with very low economic value; however, their mechanical strength is suitable for structural applications. In this study, small larch logs were sawed, dried, and cut into square timbers (with a $90mm{\times}90mm$ cross section) that were laterally glued to form core panels used to manufacture cross-laminated timber (CLT) wall panels. The surface and back of these core panels were covered with 12-mm-thick structural plywood panels, used as cross bands to obtain three-ply CLT wall panels. This attachment procedure was conducted in two different ways: gluing and pressing (CGCLT) or gluing and nailing (NGCLT). The size of the as-manufactured CLT panels was $1,220mm{\times}2,440mm$, the same as that of the plywood panels. The final wall panels were tested under lateral shear force in accordance with KS F 2154. As the lateral load resistance test required $2,440mm{\times}2,440mm$ specimens, two CLT wall panels had to be attached in parallel. In addition, the final CLT panels had tongued and grooved edges to allow parallel joints between adjacent pieces. For comparison, conventional light-frame timber shear walls and midply wall systems were also tested under the same conditions. Shear walls with edge nail spacing of 150 mm and 100 mm, the midply wall system, and the fabricated CGCLT and NGCLT wall panels exhibited maximum lateral resistances of 6.1 kN/m (100%), 9.7 kN/m (158%), 16.9 kN/m (274%), 29.6 kN/m (482%), and 35.8 kN/m (582%), respectively.

Comparison of Degradation due to Fenton Reaction between Reinforced and Non-reinforced Membranes Used in PEMFC (PEMFC에 사용되는 강화막과 비강화막의 Fenton 반응에 의한 열화 비교)

  • Oh, Sohyeong;Yoo, Donggeun;Lee, Mihwa;Park, Jisang;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.508-513
    • /
    • 2021
  • In order to improve the durability of a proton exchange membrane fuel cells (PEMFC), it is essential to improve the durability of the polymer membrane. In order to improve the durability of the membrane, an e-PTFE support and a radical scavenger are added. In this study, the chemical durability of the reinforced membrane with ePTFE support and the non-reinforced membrane was compared by Fenton reaction. In the Fenton experiment of the polymer membrane without the addition of a radical scavenger, the absorption rate of hydrogen peroxide solution and iron ions through the cross section of the specimen cut into small pieces was higher in the reinforced membrane, so that the fluorine outflow concentration was higher. According to the type and amount of radical scavenger added, the fluorine outflow concentration of the reinforced membrane has a large difference of more than 3 times, indicating that the effect of the radical scavenger was stronger than that of the support.