• 제목/요약/키워드: Forming Technique

검색결과 574건 처리시간 0.032초

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

SUMT 법(法)을 이용(利用)한 철근(鐵筋)콘크리트 뼈대구조물(構造物)의 최적설계(最適設計)에 관한 연구(研究) (A Study on the Optimal Design of Reinforced Concrete Frames Using SUMT)

  • 정영채;이규원
    • 대한토목학회논문집
    • /
    • 제4권1호
    • /
    • pp.27-48
    • /
    • 1984
  • 본(本) 연구(硏究)는 한계상태(限界狀態) 설계(設計) 이론(理論)에 의한 철근(鐵筋)콘크리트 뼈대구조물(構造物)에 관(關)한 것이다. 한계상태이론(限界狀態理論)에 의한 철근(鐵筋)콘크리트 뼈대구조물(構造物)에 대한 최적설계(最適設計)의 문제형성(問題形成)은 철근(鐵筋)의 단면적(斷面積), 단면(斷面)의 폭(幅)과 유효고(有效高) 그리고 모멘트 감소율(減少率)을 설계변수(設計變數)로 취급(取扱)하는 비선형(非線型) 계획(計劃) 문제(問題)로 된다. 목적함수(目的凾數)는 철근(鐵筋)콘크리트 뼈대구조물(構造物)의 철근(鐵筋)과 콘크리트 및 거푸집의 비용(費用)을 고려(考慮)하는 총(總) 건설경비(建設經費)로 형성(形成)되고, 기본(基本) 제약조건식(制約條件式)들은 극한(極限) 한계상태(限界狀態)와 사용성(使用性) 한계상태(限界狀態)의 개념(槪念)을 내포하고 있다. 또한 CP110과 Hognestad et al. 이론(理論)에서 가정(假定)된 응력분포도(應力分布圖)를 극한(極限) 한계상태(限界狀態)를 위해 극한(極限) 저항단면력(抵抗斷面力)을 해석(解析)하는데 적용(適用)되었고, 사용성(使用性) 한계상태(限界狀態)를 위해서는 CP110의 규준(規準)만을 사용(使用)한다. 철근(鐵筋)콘크리트 뼈대구조물(構造物)의 최적화(最適化)를 위한 비선형(非線型) 계획(計劃) 문제(問題)를 풀기 위해서 적용(適用)된 최적화(最適化) 기법(技法)은 수정(修正) Newton-Raphson 법(法)을 이용한 SUMT 알고리즘이다. 본(本) 알고리즘을 2종(種)의 뼈대구조물(構造物)에 시행(試行)해 보았고, 본(本) 알고리즘의 수감성(收歛性), 적용가능성(適用可能性) 및 안정성(安定性)을 검토(檢討)하기 위해 문헌(文獻)(10)의 수치결과(數値結果)와도 비교분석(比較分析)하였다. 결론적(結論的)으로 수치분석(數値分析)을 통(通)하여 CP110과 Hognestad et al.의 경제성(經濟性) 비교(比較)와 본(本) 알고리즘의 적용가능성(適用可能性), 안정성(安定性), 수감성(收歛性) 및 확실성(確實性) 등에 대하여 논의(論議)되었다.

  • PDF

ATP bioluminescence Assay를 이용한 대학 급식시설의 위생상태 평가에 관한 연구 (Evaluation of Hygienic Status of University Foodservice Operation using ATP bioluminescence Assay)

  • 박영숙
    • 한국식품조리과학회지
    • /
    • 제16권2호
    • /
    • pp.195-201
    • /
    • 2000
  • 대학 급식 시설의 미생물적 위생상태를 평가하기 위해서 도마, 칼, 식판 그리고 행주에 대하여 ATP bioluminescence와 표준평판 균수를 측정 비교하여 분석, 평가한 결과는 다음과 같다. 1) 도마, 칼, 식판 그리고 행주에 대한 표준평판 균수의 허용기준으로 1 $\textrm{cm}^2$당 40을 기준으로 하고 ATP bioluminescence는 800 RLU을 허용기준으로 하여 만족 할만한 수준과 시정할 수준으로 구분하여 위생상태를 평가하였을 때 ATP bioluminescence 측정값과 표준평판 균수 측정값은 84.7%의 일치도를 보였다. 2) 사용 전 도마, 칼, 식판, 및 행주의 ATP bioluminescence 측정값과 표준평판 균수 측정값의 일치도는 91.7%, 사용 중 두 값의 일치도는 75%. 그리고 세척ㆍ소독 후의 두값의 일치도는 87.5%로 사용 전의 일치도가 가장 높았고 사용 중의 일치도가 가장 낮았다. 3) ATP bioluminescence 측정과 표준 평판 균수 측정으로 얻어진 결과에서 사용 전 도마, 칼, 식판, 및 행주의 87.5%가 허용기준 이하이고, 사용 중 도마, 칼, 식판, 및 행주의 29.2%만이 허용기준 이하이며, 세척ㆍ소독 후 도마, 칼, 식판, 및 행주의 42.7%가 허용기준 이하로 사용전의 위생상태가 가장 양호하며 사용 중인 경우 위생상태가 가장 불량하여 즉각적인 조치가 필요하다. 4) 사용 전 도마, 칼, 식판, 행주 4종류의 표준평판 균수가 허용기준 이하 검출된 대학 급식 시설은 3곳이며, 사용 중 4종류의 표준평판 균수가 허용기준 이하 검출된 곳은 없었고 세척ㆍ소독 후 4종류의 표준평판 균수가 허용기준 이하 검출된 곳도 없었다. 5) 도마, 칼, 식판, 및 행주의 용도별 분리사용은 거의 이루어지고 있지 않고 있다. 특히 칼과 도마는 교차오염의 가능성이 크므로 용도에 따라 구분하여 분리 사용이 필요하며 소독방법 및 횟수에서 행주의 소독이 가장 잘 이루어지고 있으며 도마의 소독이 가장 미흡하게 나타나고 있다. 사용 중 도마, 칼, 행주에 대한 즉각적인 조치와 분리 사용이 필요하며 칼, 도마, 행주에 대한 적절한 소독 방법이 강구되어야 한다고 사려된다. 결론적으로 ATP bioluminescence 측정값은 표준평판균수 측정값과 높은 일치도를 보여 급식 분야의 미생물 품질관리 평가에 ATP bioluminescence 측정의 이용 가능성이 높게 나타나고 있으며 실제로 HACCP system에 적용하기 위하여 보다 지속적인 연구가 필요하다고 사려된다.

  • PDF

Electrochemical Characteristics of Zn and Si Ion-doped HA Films on Ti-6Al-4V by PEO Treatment

  • Lim, Sang-Gyu;Hwang, In-Jo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.199-199
    • /
    • 2016
  • Commercially pure titanium (cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Electrochemical deposition method is an attractive technique for the deposition of hydroxyapatite (HAp). However, the adhesions of these coatings to the Ti surface needs to be improved for clinical used. Plasma electrolyte oxidation (PEO) enables control in the chemical com position, porous structure, and thickness of the $TiO_2$ layer on Ti surface. In addition, previous studies h ave concluded that the presence of $Ca^{+2}$ and ${PO_4}^{3-}$ ion coating on porous $TiO_2$ surface induced adhesion strength between HAp and Ti surface during electrochemical deposition. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study electrochemical characteristcs of Zn and Si coating on Ti-6Al-4V by PEO treatment. The coating process involves two steps: 1) formation of porous $TiO_2$ on Ti-6Al-4V at high potential. A pulsed DC power supply was employed. 2) Electrochemical tests were carried out using potentiodynamic and AC impedance methoeds. The morphology, the chemical composition, and the micro-structure an alysis of the sample were examined using FE-SEM, EDS, and XRD. The enhancements of the HAp forming ability arise from $Si/Zn-TiO_2$ surface, which has formed the reduction of the Si/Zn ions. The promising results successfully demonstrate the immense potential of $Si/Zn-TiO_2$ coatings in dental and biomaterials applications.

  • PDF

열수처리에 의해 석출된 HA 결정이 Ti-6Al-7Nb 합금의 생체활성에 미치는 영향 (Effect of HA Crystals Precipitated by Hydrothermal-Treatment on the Bioactivity of Ti-6Al-7Nb Alloy)

  • 권오성;최석규;문장원;이민호;배태성;이오연
    • 한국재료학회지
    • /
    • 제14권9호
    • /
    • pp.607-613
    • /
    • 2004
  • This study was to investigate the surface properties of electrochemically oxidized Ti-6Al-7Nb alloy by anodic spark discharge technique. Anodizing was performed at current density 30 $mA/cm^2$ up to 300 V in electrolyte solutions containing $DL-{\alpha}$-glycerophosphate disodium salt hydrate($DL-{\alpha}$-GP) and calcium acetate (CA). Hydrothermal treatment was done at $300^{\circ}C$ for 2 hrs to produce a thin outermost layer of hydroxyapatite (HA). The bioactivity was evaluated from HA formation on the surfaces in a Hanks' solution with pH 7.4 at $36.5^{\circ}C$ for 30 days. The size of micropores and the thickness of oxide film increased and complicated multilayer by increasing the spark forming voltage. Needle-like HA crystals were observed on anodic oxide film after the hydrothermal treatment at $300^{\circ}C$ for 2 hrs. When increasing $DL-{\alpha}$-GP in electrolyte composition, the precipitated HA crystals showed the shape of thick and shorter rod. However, when increasing CA, the more fine needle shape HA crystals were appeared. The bioactivity in Hanks' solution was accelerated when the oxide films composed with strong anatase peak with presence of rutile peak. The increase of amount of Ca and P was observed in groups having bioactivity in Hanks' solution. The Ca/P ratio of the precipitated HA layer was equivalent to that of HA crystal and it was closer to 1.67 as increasing the immersion time in Hanks' solution.

Measurement of Quality Parameters of Honey by Reflectance Spectra

  • Park, Chang-Hyun;Yang, Won-Jun;Sohn, Jae-Hyung;Kim, Jong-Hoon
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1530-1530
    • /
    • 2001
  • The objectives of this study were to develop models to predict quality parameters of Korean bee-honeys by visible and NIR spectroscopic technique. Two kinds of bee-honey fronl acacia and polyflower sources were tested in this study. The honeys were harvested in the spring of 2000 and stored in the storage facility at 20$^{\circ}C$ during experiments. Total of 394 samples of honey were analyzed. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G (fructose/glucose) ratio, HMF (hydroxymethyl furfural), and C12/C13 ratio of honeys were measured. The average values for the tested honeys were 19.9% of moisture contents, 0.12% of ash, 68.4% of invert sugar, 5.7% of sucrose, 1.27 of F/G(fructose/glucose) ratio, 14.4 mg/kg of HMF, and -19.1 of C12/C13 ratio. A spectrophotometer, equipped with a single-beam scanning monochromator (NIR Systems, Model 6500, USA) and a horizontal setup module, was used to collect reflectance data from honey. The reflectance spectra were measured in wavelength ranges of 400∼2,498 nm. with 2 nm of interval. Thirty-two repetitive scans were averaged, transformed to log(1/Reflectance), and then were stored in a microcomputer file, forming one spectrum per measurement. A sample cell and reflectance plate were made to hold honey samples constantly. Spectra of honey samples were divided into a calibration set and a validation set. The calibration set was used during model development, and the validation set was used to predict quality parameters from unknown spectra. The PLS(Partial Least Square) models were developed to predict the quality parameters of honeys. The first and the second derivatives of raw spectra were also used to develop the models with proper smoothing gap. The MSC (multiplicative scatter correction) and the SNV & Dtr.(standard normal variate and detranding) preprocessing were applied to all spectra to minimize sample-to-sample light scatter differences. The PLS models showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1100∼2200 nm. However, the PLS analysis was not good enough to predict HMF of honeys.

  • PDF

급식소 식품접촉표면 위생 모니터링 도구로서의 ATP Luminometer 적합성 확인 (Verification of the Suitability of the ATP Luminometer as the Monitoring Tool for Surface Hygiene in Foodservices)

  • 김양숙;문혜경;강성일;남은정
    • 한국식품영양과학회지
    • /
    • 제39권11호
    • /
    • pp.1719-1723
    • /
    • 2010
  • 창원시 소재 단체급식소 4개소에서 사용하는 칼($12\;cm^2$), 도마($100\;cm^2$), 고무장갑(손바닥과 손가락 사이)의 표면을 대상으로 ATP Luminometer와 일반세균수용 건조필름을 이용한 미생물 배양법을 함께 적용하여 ATP(RLU)와 APC (CFU)을 측정하였다. 통계분석 결과, 3가지 조리도구 모두에서 ATP(RLU)와 APC(CFU) 간에 유의적인 양의 상관성이 존재하였다. 각 도구별 상관계수는 칼 0.84(p<0.001), 도마 0.79(p<0.001), 고무장갑 0.78(p<0.001)로 나타났다. 본 실은 단체급식 현장에 적합한 ATP Luminometer 가이드라인을 설정하기에 앞서 실시간적인 표면 위생 모니터링 도구로서의 사용 적합성을 살펴 본 예비실험이며, 도출된 회귀식을 이용하여 도구별 ATP(RLU) 가이드라인을 설정하고 검증할 예정이다.

참치 기름담금 통조림의 $F_0$-값 설정에 관한 연구 (Establishment of $F_0$-value Criterion for Canned Tuna in Cottonseed Oil)

  • 한봉호;조현덕;유홍식;김상호;정윤수
    • 한국수산과학회지
    • /
    • 제27권6호
    • /
    • pp.675-681
    • /
    • 1994
  • 통조림 식품의 가열살균 공정은 에너지 소비와 제품의 미생물학적 안전성, 영양적 및 기호적 품질을 감안하여 최적화되어야 한다. 본 연구에서는 일차적으로 가열살균에 따른 에너지 소비와 제품의 미생물학적 안전성과의 관계를 최적화하고자 하였다. 참치 기름담금 통조림을 서로 다른 살균조건 즉, $F_0$-값을 달리하여 열처리하고, 마이크로 컴퓨터를 이용하여 자체 개발한 $F_0$-값 측정 씨스템을 사용하여 측정한 $F_0$-값과 미생물학적 안전성과의 관계를 조사하여 적정 $F_0$-값을 제시하였다. 참치 기름담금 통조림의 냉점은 시험대상 통조림의 기하학적 중심이 아니라 내용물의 무게 중심이었으며, 시험대상 통조림들을 레토르트에 무작위하게 넣는 경우에 레토르트 내의 통조림의 위치는 F0-값에 영향을 미치지 않았다. 또한 미생물에 의한 원료의 오염방지를 위하여서는 가열살균 이전의 공정을 가능한 한 단축시켜야 함을 확인하였다. 원료 및 자숙한 참치에서 분리된 내열성 박테리아는 S. subtilis, B. cereus 및 B. pasteurii였고 이 중 내열성이 가장 큰 것은 B. subtilis였으나, $F^0$-값 6분 이상의 제품에서는 저장 중에도 미생물이 전혀 검출되지 않았으며, 상업적 살균에 의해 생산되는 참치 기름담금 통조림의 가열살균 기준으로는 $F_0$-값 6분이 적당한 것으로 판단되었다.

  • PDF

금속류 행정박물의 손상도 및 재질 연구 (Deterioration Degree and Material Research of Metal Archival Objects)

  • 박형호;조남철;나미선
    • 보존과학회지
    • /
    • 제26권1호
    • /
    • pp.33-41
    • /
    • 2010
  • 행정박물이란 공공업무의 활동을 반영하는 유형적 증거물로서 행정적 역사적 상징적 문화적 예술적 가치를 지니는 형상기록물이며 세계 여러 나라에서 제작되어 재질과 제작기법이 다양하지만, 재질조사 및 보존관리 시스템이 확립되지 않아 효율적인 보존관리의 어려움이 많다. 그러므로 본 연구에서는 금속류 행정박물에 대한 재질조사와 상태점검을 통하여 효율적인 보존관리를 위한 기초자료를 제시하고자 한다. 금속류 행정박물 중 상태점검 및 재질 분류는 공직자 선물 가운데 변색, 산화, 결손 및 균열이 기록된 12점을 선별하여 조사하였다. 행정박물의 전반적인 상태를 점검하기 위해 국내 박물관, 미술관 및 일본민족학박물관에서 사용하는 상태점검카드를 수집 정리하여 새로운 점검카드를 작성 후 금속류 행정박물을 점검하였다. X-ray를 통해 행정박물의 제작기법과 소재간의 결합방법, 구조상 취약부분에 대하여 조사하였으며 P-XRF를 사용하여 행정박물의 재질 분석을 시도하여 각 재질별 분류를 실시하였다. 점검결과 행정박물의 외형적 특성과 손상부분에 대한 점검이 가능하고 구조적으로 취약한 부분을 관찰 할 수 있었다. 또한 P-XRF 측정을 통하여 재질이 미상으로 기록된 행정박물의 재질을 밝혀내었고 기록카드에 기재된 재질과 다른 재질을 찾아낼 수 있었다. 행정박물의 상태점검 및 손상정도, 재질별 분류 방법은 향후 보존관리를 위한 자료로써 활용이 가능하며 재질에 따른 훼손 방지 및 관리를 위한 보존관리지침 수립 등 장기보존을 위한 기초자료로서도 활용이 가능한 것으로 보인다.

KURT 지하수의 천연 유기물질과 6가 우라늄 화학종의 상호작용에 관한 연구 (Study on the Interaction of U(VI) Species With Natural Organic Matters in KURT Groundwater)

  • 정의창;백민훈;조혜륜;김희경;차완식
    • 방사성폐기물학회지
    • /
    • 제15권2호
    • /
    • pp.101-116
    • /
    • 2017
  • KURT(KAERI Underground Research Tunnel) 지하수에 존재하는 천연 유기물질과 6가 우라늄(U(VI))화학종의 상호작용을 레이저 분광학 기술을 이용하여 조사하였다. 지하수 시료에 266 nm 파장의 레이저 빛을 입사시켜 자외선 및 파란색 파장 영역에서 방출되는 천연 유기물질의 발광 스펙트럼을 관측하였다. $0.034-0.788mg{\cdot}L^{-1}$ 농도 범위의 우라늄이 함유된 지하수에서는 녹색 파장 영역에서 방출되는 U(VI) 화학종의 발광 스펙트럼을 측정하였다. 지하수에 함유된 U(VI) 화학종의 발광 특성(피크 파장 및 발광 수명)이 실험실에서 제조한 표준용액에 함유된 $Ca_2UO_2(CO_3)_3(aq)$의 발광 특성과 매우 유사하다는 것을 확인하였다. 지하수에 존재하는 U(VI) 화학종의 발광 세기는 표준용액에 함유된 같은 농도의 $Ca_2UO_2(CO_3)_3(aq)$의 발광세기에 비해 약하다. 표준용액의 $Ca_2UO_2(CO_3)_3(aq)$를 천연 유기물질이 함유된 지하수에 섞었을 때에도 $Ca_2UO_2(CO_3)_3(aq)$의 발광 세기가 감소한다. 이러한 현상의 원인을 지하수의 천연 유기물질과 Ca-U(VI)-탄산염 화학종의 상호작용으로 인해 비발광성 U(VI) 착물이 형성되기 때문인 것으로 설명하였다.