• Title/Summary/Keyword: Flow Verification

검색결과 690건 처리시간 0.025초

Study on Antecedent Moisture Condition for Seolma Stream Basin

  • Ly, Sidoeun;Shin, Hyun Seok;Kim, Duck Hwan;Kim, Beom Jun;Kim, Hung Soo
    • 한국습지학회지
    • /
    • 제15권4호
    • /
    • pp.609-618
    • /
    • 2013
  • Curve number (CN), originally developed, compiled by 'The Natural Resources Conservation Service (NRCS)', and has been widely used throughout the world. However, there is the uncertainty of CN derived from the use of antecedent moisture condition (AMC)/Antecedent Runoff Condition (ARC). As in Korea where nearly 70% covered by mountainous area, it is still not sufficient handbook precedent to guide or support the estimation of AMC/ARC. The failure to develop formal criteria of applying AMC/ ARC will be a gaping profession and results not only in uncertainty of CN estimation in particular, but also in designing appropriate structures in Korea as a whole. This paper is aiming at presenting a critical review of AMC/ARC and deriving a procedure to deal more realistically with event rainfall-runoff over wider variety of initial conditions. Proposed methods have been developed. It is based on modifying estimated runoff to observed runoff with coefficient of determination and then applying different algebraic expression with the verification of AMC by antecedent rainfall table of NEH-1964. The result shows that algebraic expression by Arnold et al. (1996) is the most appropriate for AMC/ARC and the results of AMC/ARC estimation criteria are generally very close to each other. Therefore, this algebraic expression might be applied in South Korea condition properly.

3차원 열유체 수치해석을 통한 현장 시공된 수직 밀폐형 지중열교환기의 열전달 거동 평가 (Heat transfer analysis of closed-loop vertical ground heat exchangers using 3-D fluid flow and heat transfer numerical model)

  • 박문서;이철호;민선홍;강신형;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.800-807
    • /
    • 2010
  • In this study, a series of numerical analyses has been performed in order to evaluate the performance of a full-scale closed-loop vertical ground heat exchanger constructed in Wonju. The circulation pipe HDPE, borehole and surrounding ground were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow water and the change of the surrounding ground temperature with depth were adopted in the FLUENT model. The thermal properties of materials estimated in laboratory were used in the numerical analyses to compare the thermal efficiency of the cement grout with that of the bentonite grout used in the construction. The results of the simulation provide a verification of the in situ thermal response test data. The numerical model with the ground thermal conductivity of 4W/mK yielded the simulation result closer to the in-situ thermal response test than with the ground thermal conductivity of 3W/mK. From the results of the numerical analyses, the effective thermal conductivities of the cement and bentonite grouts were obtained to be 3.32W/mK and 2.99 W/mK, respectively.

  • PDF

공간 콜래보레이션이 적용된 상업공간사례 검토 -헤이리 마을의 4사례 검토를 통하여- (The Case Study on the Commercial Space with Space Collaboration -Through 4 Case Studies in Heyri Village -)

  • 신지현;신경주
    • 한국실내디자인학회논문집
    • /
    • 제24권3호
    • /
    • pp.15-29
    • /
    • 2015
  • Social and cultural impact of postmodernism in the seek for diversity and to respect the individual's personality and character was the center of human-centered thinking. This also affects the design area, as well as architecture, interior design. It is because of interactive interior design that reflects the lives and relationships with people. Thus, in modern society, people to meet the diverse needs have created a third space. Today's commercial space in the flow to a variety of users and is trying to provide comfort. To go to stores often offer lifestyle and proceeding to the next stage of life. Space for the creative force is trying to become getting better space. Collaboration is refer to phenomenon that two or more objects meet to collaborate. Collaboration is can be classified of space, art, low/high, high concept and star collaboration. And this study has been studied mainly collaboration. Space collaboration is can be classified of experiential, the third space, brand passes and landmark. Space collaboration elements rearranged to the standards of interior design theory, analysis, and marketing of space, commercial space, with previous studies of the spatial elements were extracted. The purpose of this study in the field of interior design space analysis method for the verification of collaboration theory is that to develop. Thus, the space collaboration has been developed to fit the field of interior design, and commercial interior spaces will be helpful for applying.

직렬 링크 방식의 주변 장치 통합 인터페이스 설계 (Design of General Peripheral Interface Using Serial Link)

  • 김도석;정훈주;이용환
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권1호
    • /
    • pp.68-75
    • /
    • 2011
  • 최근 주변 장치의 성능은 사용자들이 요구하는 멀티미디어 데이터를 충족하기 위해 급속히 증가하고 있으며 고성능 장치에 실시간으로 데이터를 제공하기 위해 주변 장치의 인터페이스는 넓은 대역폭과 높은 전송속도가 필요하게 되었다. PCI Express는 고속의 직렬 전송 인터페이스로 이전의 PCI와 PCI-X와 상호 호환이 되는 인터페이스이다. 본 논문에서는 직렬 링크 방식의 주변 장치 통합 인터페이스 설계하였다. TC/VC 매핑 기법과 VC 중재 기법을 사용해 우선순위에 의한 패킷 전송이 가능하도록 하였고, 4개의 레인을 사용하여 패킷을 전송하도록 하였다. Verilog HDL을 사용하여 인터페이스를 설계하였고 이를 Modelsim으로 검증하였다. FPGA 검증은 Xilinx ISE와 SPARTAN XC3S400을 사용하였으며 합성은 Synopsys Design Compiler를 사용하여 검증하였다.

진공용 공기베어링의 성능해석 (Performance Analysis of a Vacuum-Compatible Air Bearing)

  • 김경호;박천홍;이후상;김승우
    • 한국정밀공학회지
    • /
    • 제23권10호
    • /
    • pp.103-112
    • /
    • 2006
  • This paper describes a theoretical analysis and experimental verification on the performances of a vacuum-compatible air bearing, which is designed with a cascaded exhaust scheme to minimize the air leakage in a vacuum environment. The design of the vacuum-compatible air bearing equipped with the differential exhaust system requires great care because several design parameters, such as the number of exhaust stages, diameter of exhaust tube, pumping speed of a vacuum pump, and bearing clearance greatly influence the air leakage and thus degree of vacuum. In this study, a performance analysis method was proposed to estimate the performances of the air bearing, such as load capacity, stiffness, and air leakage. Results indicate that the load capacity and stiffness of the air bearing was improved as its boundary pressure, which was determined by the $1^{st}$ exhaust method, was lowered, and the dominant factors on the chamber's degree of vacuum were the number of exhaust stages, exhaust tube diameter and bearing clearance. A vacuum chamber and air bearing stage using porous pad were fabricated to verify the theoretical analysis. The results demonstrate that chamber pressure up to an order of $10^{-3}$ Pa was achieved with the air bearing stage operating inside the chamber, and this analysis method was valid by comparing predicted values with experimental data, for the mass flow rates from the porous pad, and pressures at each exhaust port and chamber, respectively.

가압경수로용 환형 실린더 연료봉의 단면치수와 스팬길이에 따른 진동특성해석 (Vibration Characteristic Analysis of an Annular Cylindrical PWR Fuel Rod according to the Cross-sectional Dimensions and the Span Length)

  • 이강희;김재용;이영호;윤경호;김형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.197-201
    • /
    • 2007
  • Vibration characteristics of an annular cylindrical fuel rod, which was proposed as a candidate design of fuel's cross section for the ultra-high burnup nuclear fuel, according to the cross-sectional dimensions and the number of supports or the span length were analytically studied. Finite element(FE) modeling for the annular cross sectional fuel was based on the methodology, that have been proven by the test verification, for the conventional PWR nuclear fuel rod. A commercial FEA code, ABAQUS, was used for the FE modeling and analysis. A planar beam element (B21) that uses a linear interpolation was used for the fuel rod and a linear spring element for the spring and dimple of the SG. Natural frequencies and mode shape were calculated according to the preliminary design candidates for the fuel's cross sectional dimension and the number of span. From the analysis results, the design scheme of the annular fuel compatible to the present PWR nuclear reactor core was discussed in terms of the number of supports and fuel's cross section.

  • PDF

제품에 대한 사용자의 가치의식에 따른 디자인 평가의 유형에 관한 연구 (A Study on User's Value Consciousness toward Products and Patterns of Design Evaluation)

  • 송창호;최명식
    • 디자인학연구
    • /
    • 제19권5호
    • /
    • pp.255-268
    • /
    • 2006
  • 본 연구에서는 '제품에 대한 사용자의 심리적 가치의식이 디자인 평가에 어떠한 작용을 하는가'에 문제의식을 제기하여 14가지의 제품 샘플을 대상으로 평가를 실시하였다. 이에 따른 주요내용은 '제품평가의 단계별 사고', '제품에 대한 가치의식', '조형이미지 생성과 디자인 평가' 등 크게 3가지 영역을 주요 골자로 하여 분석을 실시하였다. 결론 도출을 위해 먼저 4개의 연구가설을 설정하였고, 이를 검증하기 위하여 '종결적 조사'의 일환으로 사례연구를 실시하였다. 표본은 데이터의 정확성을 높이기 위하여 제품디자인을 전공으로 하는 20대 대학생 120명을 대상으로 선정하였다. 수집된 데이터는 '단순집계'에 의하여 전체적인 흐름을 파악하였고, 이를 토대로 3개의 평가항목에 대한 구체적인 분석을 실시하였다. 분석방법은 '요인분석(factor analysis)', '클러스터분석(duster analysis)' 등 '다변량분석(multivariate analysis)'에 의한 '정량적 분석'에 중점을 두었다. 본 연구의 실증분석은 유의수준 p<.05에서 검증하였고, 통계처리는 'SPSSWIN 12.0' 프로그램을 사용하였다. 그 결과 '제품에 대한 사용자의 가치의식에 따른 디자인 평가의 유형'에 관해 4가지 결론을 얻었다.

  • PDF

Systems Engineering Approach to the Heat Transfer Analysis of PLUS 7 Fuel Rod Using ANSYS FEM Code

  • Park, Sang-Jun;Mutembei, Mutegi Peter;Namgung, Ihn
    • 시스템엔지니어링학술지
    • /
    • 제13권1호
    • /
    • pp.33-39
    • /
    • 2017
  • This paper describes the system engineering approach for the heat transfer analysis of plus7 fuel rod for APR1400 using, a commercial software, ANSYS. The fuel rod is composed of fuel pellets, fill gas, end caps, plenum spring and cladding. The heat is transferred from the pellet outward by conduction through the pellet, fill gas and cladding and further by convection from the cladding surface to the coolant in the flow channel. The goal of this paper is to demonstrate the temperature and heat flux change from the fuel centerline to the cladding surface when having maximum fuel centerline temperature at 100% power. This phenomenon is modelled using the ANSYS FEM code and analyzed for steady state temperature distribution across the fuel pellet and clad and the results were compared to the standard values given in APR1400 SSAR. Specifically the applicability of commercial software in the evaluation of nuclear fuel temperature distribution has been accounted. It is note that special codes have been used for fuel rod mechanical analysis which calculates interrelated effects of temperature, pressure, cladding elastic and plastic behavior, fission gas release, and fuel densification and swelling under the time-varying irradiation conditions. To satisfactorily meet this objective we apply system engineering methodologies to formulate the process and allow for verification and validation of the results acquired. The close proximity of the results obtained validated the accuracy of the FEM analysis of the 2D axisymmetric model and 3D model. This result demonstrated the validity of commercial software instead of proprietary in-house code that is more costly to develop and maintain.

도시유출해석을 위한 도시수문 모니터링 기법 적용 (Application of Urban Hydrologic Monitoring System for Urban Runoff Analysis)

  • 서규우
    • 한국방재학회 논문집
    • /
    • 제5권2호
    • /
    • pp.37-44
    • /
    • 2005
  • 본 연구의 대상유역인 동의대 시험유역은 공간적으로 주위가 산의 능선으로 둘러싸여 유역내의 유출은 거의 대부분 단일 유출구로만 유출이 이루어지며, 부산지방의 도시유역의 특징인 경사지형의 특성을 잘 반영하고 있다. 유역기초자료 및 기상관측장비(EMS)와 자동수위관측장비(AWS)를 통해 수집된 각종 수문자료들과 유역상세자료들을 조사하여 ILLUDAS 모형과 SWMM 모형, HEC-HMS 모형의 기본입력자료로 사용하여 시험유역 유출특성을 검토하고, HEC-HMS 모형에 대한 검정 및 검증을 통해 시험유역 저류지설계에 사용한다. HEC-HMS 모형에 소하천 설계기준인 30년 설계강우를 설정하고 불투수율의 변화양상에 따라 설계홍수량을 산정하고, 유출누가곡선상에서 저류지의 용량을 결정하였다. 시험유역의 최종 유출부 상류에 $54,000m^3$의 가상 저류지를 설계하였고, 저류지 설계 후 유출양상을 검토해본 결과 유출의 첨두량이 감소함을 확인할 수 있었다. 이는 저류지설계로 도시지역의 유출이 감소됨으로서 도시홍수방재에 있어서 적용성이 있음을 확인할 수 있었다.

Better Housing for Effective Pig Production - Review -

  • Choi, H.L.;Song, J.I.;An, H.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권8호
    • /
    • pp.1310-1315
    • /
    • 1999
  • Air quality in confinement pig houses is important to production and health. Mechanical ventilation and confinement is known to be the most practical tool for maintaining adequate air quality in pig houses through extensive researches since Millier (1950) invented the 'slotted inlet' ventilation system. A variety of mechanical ventilation systems have been applied to confined nursery pig houses in Korea without scientific verification of their ventilation effectiveness. Ventilation systems with three feasible combinations (NA, NB, and NC) of inlets and outlets in a confined nursery pig house were tested to evaluate their ventilation efficiency, of which the one with the performance was supposed to be taken as a standard ventilation system for nursery pig houses in Korea. Field data of air velocity and temperature fields, and ammonia concentration with three ventilation systems were taken and compared to determine the best system. The air velocity and temperature fields predicted by the PHOENICS computer program were also validated against the available experimental data to investigate the feasibility of computer simulation of air and temperature distribution with an acceptable accuracy in a confined house. NC system with duct-induced in-coming air, performed best among the three different ventilation systems, which created higher velocity field and evener distribution ($2.5m/s{\pm}0.3m/s$) over the space with a Reynolds number of $10^4$. The experimental data obtained also fitted well with the simulated values using the modified PHOENICS, which suggested a viable tool for the prediction of air and temperature field with given calculation geometries.