• Title/Summary/Keyword: Flashover voltage

Search Result 162, Processing Time 0.023 seconds

Influence of the Combustion Flame on the Dielectric Strength of an Air Gap due to Fire Occurrence (화재발생에 따른 연소화염이 공기의 절연내력에 미치는 영항)

  • 김인식;하장호
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.30-38
    • /
    • 2002
  • Occurring fire or burning bushes beneath overhead power lines have caused system disturbances in many countries. In this study, various tests in the simulated condition of power lines were conducted so as to investigate the reduction in insulation strength caused by combustion flame. Characteristics of the ac and dc flashover voltages in the vertical needle-plane, sphere-plane and rod-plane electrode system were investigated when the combustion flames were present near the high-voltage electrode. As the results of an experimental investigation, It was found that the average reduction characteristics of flashover voltages with the sphere-plane system, in comparison with the no-flames case, were about 1/3 times when the ac voltages were applied.

Wet Flashover Characteristics and Reform Measure of a Conventional Lightning Rod against Lightning Impulse Voltages (뇌임펄스전압에 대한 돌침형 피뢰침의 주수섬락특성과 개선 방안)

  • 이복희;강석만;엄주홍;이승칠;김승지
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.93-100
    • /
    • 2002
  • In this paper, in ordor to examine the relevant technical facts which are very instructive to revise the domestic standard for lightning protection systems, standards and technical guideline for the protection of structure against lightning were reviewed, and several issues of the domestic standards were experimentally investigated. As a consequence, the insulator of relatively low implse voltage and a large percentage of lighting rods is flashovered by relatively low impulse voltage and a lage percentage of lighting current flows through supporting mast. Thus the potential gradient in the vicinity of supporter for lighting rods is extremely increased and the role of lighting propection systems is nullified. It seems obvious that the flashover of insular supporting lighting rod can range from erratic operation of microelectronic devices to minor physical ham or even death, or costly damage electrical equipment.

The analysis of leakage current characteristics of polymer insulators for estimation under Pollution conditions (고분자 절연물의 내오손 진단을 위한 누설전류 특성 해석)

  • Kim, I.S.;Han, S.W.;Cho, H.G.;Soh, J.J.;Kim, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1452-1454
    • /
    • 1997
  • Properties of flashover in polymer insulators are very important under pollution environments. It is necessary to analyse flashover characteristics whether insulators are still safe or not. A lot of precious information can be got out of polluted polymer insulators through leakage current measurement. The behavior of partial arc discharge leads to flashover directly. It is possible to measure partial arc discharge as leakage current pulses analysis. The shape of histogram reflects degree of pollution, wetting and voltage stress level. It can be expressed by Weibull distribution function.

  • PDF

The Evaluation of Surface Characteristics by Using Surface Discharge Method for Porcelain Suspension in Insulators (표면방전을 이용한 자기제 현수애자의 표면특성 평가)

  • 송일근;김찬영;한용희;윤영숭;안규선;임장섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.199-202
    • /
    • 1999
  • The paper deals with the surface discharge characteristics for porcelain suspension insulators. The micro-crystals were crystallized on the surface of glace coated on the porcelain These micro-crystals may affect the electrical Properties such as flashover voltage. However. not much research have been conducted. In this study. we correlated the surface discharge characteristics to the microstructures. It was confirmed that the micro-crystals on the glaze initiated the flashover when the surface was wetted and/or contaminated.

  • PDF

A Study on the Flashover Properties of Insulators with Artifitial Pollution (오손조건에 따른 애자의 섬락 특성에 관한 연구)

  • 송치훈;조성인;국연호;남궁도;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.679-682
    • /
    • 2000
  • This paper present the result of the flashover properties of inulators due to artifitial pollution. For this study, a mini fog chamber has been fabricated with transparent acryl which has the merit in observasion and electrical insulation. All the experiment was carried in mini fog chamber. Though non-souble contaminant do not distribute on the electric conductivity of contaminant and contaminated insulator, that influence on the flashover characteristics of insulators. with the result, we assume phenomenon caused with the hygroscopic property of non-soluble contaminant.

  • PDF

The Influence of Forest Fire Simulation on the Properties of Polymer Insulators

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Dong-Il;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • Forest fire simulation tests were performed with polymer and porcelain insulators at GOCHANG Power Testing Center. These tests consisted of open flames causing a temperature rise of up to $600{\sim}800^{\circ}C$ measured at the insulator surfaces. Mechanical and electrical characteristics such as the specific mechanical load, the low frequency dry flashover voltage and the impulse flashover voltage were analyzed for the polymer insulators before, during and after the simulation tests and then compared to the porcelain insulators. At the end of the fire simulation tests, there was no detrimental deterioration of any of the insulators. All the insulators passed the KEPCO specification criteria. This study showed that the forest fire simulation had no impact on the polymer insulators.

Influence of Tank Inner Side Dielectric Coating on the Particle Behaviour and Flashover Voltage in SF\ulcorner Gas Insulated System

  • Lee, Bang-Wook;Koo, Ja-Yoon
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.77-81
    • /
    • 1997
  • In his work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when the epoxy resin based dielectric coating was made on he inner side of outer electrode. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various sizes of Cu conducting particle were used under different gas pressures. In order to elucidate the coating effect on the gas insulation, different thickness of dielectric coating has been considered and then the lift-off voltage and flashover voltages have been measured. The results shown that the dielectric coating has a remarkable influence by restraining the movement of particle in GIS system, and thus GIS insulation reliability is noticeably improved.

  • PDF

Flashover Characteristics of The Vertical Disposition Electrode Caused by Combustion Flames (연소화염에 의한 수직배치 전극의 플레시오버 특성)

  • Lee, Sang-Woo;Kim, Chung-Nyun;Lee, Seung-Wook;Kim, In-Sik;Kim, Lee-Kook;Bak, Jai-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.208-212
    • /
    • 2001
  • In this paper, characteristics of the ac and do flashover voltages in the vertical air gap of a needle-plane, sphere-plane and rod-plane electrode system were investigated when the combustion flames were present near the high-voltage electrode. As the results of an experimental we found that the reduction of flashover voltages characteristics with the vertical distance caused, in comparison with the no-flame case were about 1/3 times when a short sap d=1[cm] and 2[cm] of the ac voltages were applied. Also, flashover voltages characteristics of the do negative polarity under sphere-plane and rod-plane electrode system with the combustion flame were increased about two times than those of the do positive polarity.

  • PDF

Analysis of Flashover Rate by Lightning in Korea Distribution Line using CRIEPI Method (CRIEPI 방식을 이용한 국내 가공 배전선로에서의 뇌 섬락률 산정)

  • Choi, Sun-Kyu;Seo, Hun-Chul;Han, Jun;Kim, Chul-Hwan;Lee, Byung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • This paper analyzes the flashover rate by lightning in Korea distribution system. Because of random characteristics of lightning, the Monte Carlo method is applied to estimate the lightning performance. The magnitude of lightning stroke is based on the curve measured in field. The classification of direct and indirect lightning depends on the striking distance. The striking distance and flashover rate are calculated by using the method based on Central Research Institute of Electric Power Industry(CRIEPI). The distribution system and lightning is modeled by using EMTP and MATLAB, and the accuracy of modeling is discussed. The simulations for the various spacing between two adjacent surge arresters and the various grounding resistance of GW according to the existence of GW are performed and the simulation results are analyzed.

Surface Flashover Characteristics on Poor Contact in N2/O2 Mixture Gas under Non-Uniform Field (불평등 전계 중 불량 접촉갭에 관한 N2/O2 혼합가스의 연면플래쉬오버특성)

  • Lim, Dong-Young;Choi, Eun-Hyeok;Choi, Sang-Tae;Choi, Byoung-Ju;Lee, Kwang-Sik;Bae, Sungwoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.63-69
    • /
    • 2015
  • This paper presents the surface flashover characteristics to simulate the poor contact between an anode and a solid dielectric in a $N_2/O_2$ mixture gas (8/2) under a non-uniform field. The surface flashover voltage of the $N_2/O_2$ mixture gas revealed the irregular tendency that was not in accordance with the Paschen's law with an increasing gap of the poor contact. In addition, the insulation performance of the $N_2/O_2$ mixture gas at 0.6MPa was comparable to that of $SF_6$ gas of 0.1MPa based on the insulation performance on the poor contact. These results are able to apply the insulation design of eco-friendly gas insulation switchgear considering the internal faults.