Influence of Tank Inner Side Dielectric Coating on the Particle Behaviour and Flashover Voltage in SF\ulcorner Gas Insulated System

  • Published : 1997.06.01

Abstract

In his work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when the epoxy resin based dielectric coating was made on he inner side of outer electrode. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various sizes of Cu conducting particle were used under different gas pressures. In order to elucidate the coating effect on the gas insulation, different thickness of dielectric coating has been considered and then the lift-off voltage and flashover voltages have been measured. The results shown that the dielectric coating has a remarkable influence by restraining the movement of particle in GIS system, and thus GIS insulation reliability is noticeably improved.

Keywords

References

  1. IEEE Trans. on EI. v.EI-16 no.5 A Review Of Particle Contaminated Gas Breakdown J.R.Laghari;A.H.Qureshi
  2. IEEE Trans. on EI. v.EI-16 no.4 Free Conducting Particles in Compressed Gas Insulation H.Anis;K.D.Srivastava
  3. IEEE Trans. on PAS. v.PAS-98 no.3 Particle-Initiated Breakdown in $SF_6$ Insulated Systems under High Direct Voltage F.A.M.;C.Masetti;R.P.Comsa
  4. IEEE Trans. on PAS v.PAS-104 no.1 Dielectric Coatings Effect on Breakdown and Particle Movement in GITL Systems K.D.Srivastava;R.G.van Heeswijk
  5. IEEE Trans. on Power Delivery v.PWRD-1 no.1 Particle Initiatd Breakdown Characteristics and Reliability Improvement in $SF_6$ Gas Insulation F.Endo(et al.)
  6. 6th ISH 32. 06 Breakdown Characteristics of Dielectric Coated Electrodes in Sulphur HexaFluoride Gas with Particle Contamination H.Anis;K.D.Srivastava
  7. 3rd ISH 11.15 Field Computation around a Charged Sphere near a Dielectric Coated Conducting Plate and under a Uniform External Electric Field Y.L.Chow(et al.)