• 제목/요약/키워드: Fixed Measuring Equipment

검색결과 14건 처리시간 0.023초

파악력 평가도구 개발모형에 관한 연구 (A Study of Hand-Grip Strength Assessment Equipment Prototype for Visual Perception)

  • 김은정;박지환
    • 대한정형도수물리치료학회지
    • /
    • 제17권1호
    • /
    • pp.24-28
    • /
    • 2011
  • Background: The purpose of this study is to make a grip strength checker to make people measure their grip strength easily, based on standardized grip strength checker chart. Method: In this study, we measured right hand grip strength of 80 women residents of Deajeon (women in their 30s to 60s, 20 in each) 2 times per day for 5days in same conditions from 20th of November 2010 to 24th of November. it was measured by Jamar Hydraculic Hand Dynamometer made lately to compare with the current measuring equipment. No matter how big their hands are, their hands were fixed at second level. Measured as they sit on a chair and let their shoulders gathered and not be rotated, let their arms be 90 degree, wrist and forearm be at the middle for the first time, and took another after they took a rest, and measured the average of the two. Result: There was not a meaningful difference between the current measuring equipment and the equipment made lately (p>.05). Conclusion: It is thought that the equipment made lately can be believed. In addition, we want people to realize their own grip strength easily by this study.

  • PDF

생활권역별 환경안전 실시간 모니터링 시스템의 개발 (Development of Environmental Safety Real-Time Monitoring System by Living Area)

  • 이주현;김주호;이승호
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.1088-1091
    • /
    • 2019
  • 본 논문에서는 생활권역별 환경안전 실시간 모니터링 시스템을 제안한다. 제안하는 시스템은 고정형 및 이동형 측정장비를 활용하여 방사선, 미세먼지, 생활기본정보(온도) 등을 측정 하도록 설계된다. 고정형 및 이동형 측정장비로부터 수신한 데이터를 저장하는 웹 데이터베이스를 구성한다. 또한 수신한 데이터를 PC에 디스플레이하기 위한 웹 프로그램과 휴대폰에 디스플레이 위한 웹 프로그램을 개발한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선 측정범위는 세계 최고 수준과 버금가는 $10{\mu}Sv/h{\sim}10mSv/h$의 범위에서 측정이 되었고, 정확도는 ${\pm}6.7%{\sim}8.7%$의 측정 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다. 4계절을 보유한 우리나라의 온도변화 특성에 따라 $-20^{\circ}C{\sim}50^{\circ}C$의 구간에 대해 온도 시험을 수행하였으며 온도변화에 대응하여 정상동작 됨이 확인되었다. 복사전자파 내성 시험의 경우에 적합 판정으로 안정성이 확보되었다. 시제품 제작이후 약 4개월 동안 일반환경 및 고온과 저온 환경에서 제품을 테스트한 결과, 구성된 센서의 보증기간 및 운영테스트 시 작동 및 기록되는 데이터를 기반으로 약 5년 이상의 내구성이 확인되었다. 미세먼지 센서에 대한 측정범위와 정확도는 대기환경 측정 기업을 통하여 상대성 비교 테스트를 진행하고 대기질 측정 기록부를 통하여 성능수준이 유사함을 확인하였다.

적외선열화상처리장치를 이용한 충돌제트의 전열특성에 관한 연구 (A Study on Heat Transfer Characteristics of Impinging Jet Using Infared Thermal Image Processing System)

  • 김동균;배석태;김시범;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.711-716
    • /
    • 2001
  • This paper presents an information about the heat transfer characteristics of impinging jet in eletronic equipment with infrared image processing unit. There have been many experimental investigations and theoretical studies on impinging jet because of application in a wide variety of industrial process including electronic equipment. In this study, we used infrared image processing unit to visualize heat transfer characteristics of impinging jet in electronic equipment. Infrared image processing unit is one of non-contact temperature measuring methods and it is possible to minimize flow resistance and this measurement is comparatively accurate. The main parameters are nozzle exit angle $(30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ})$ and distance between nozzle and heat source is fixed 6d("d" is diameter of circular nozzle(10 mm). Reynolds number is 4500.

  • PDF

주문진 표준사를 이용한 대형 공진주 시험 장비의 검증 (Verification of the large scale, free-free resonant testing equipment using Jumunjin sand)

  • 박인범;박철수;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1415-1424
    • /
    • 2009
  • Measuring dynamic properties of gravel-sized materials demands large specimens. Due to the difficulties in experiment as well as equipment, the dynamic properties of gravel-sized material has rarely been investigated. To realize free-free end condition more properly and stabilize specimen during testing with new specimen support system, a free-free resonant column testing device, which is capable of testing gravel-sized materials and constraining a specimen in free-free boundaries, is developed. We report the calibration of the equipment and preliminary testing results on Jumunjin sand. The testing data are compared with the previous data obtained from the existing fixed-free resonant column test.

  • PDF

반도체 Package 공정용 EMC Gun에 관한 연구 (A Study on the Semi-conductor Package Process Epoxy Moulding Compound Gun)

  • 조명현;김규성
    • 전자공학회논문지 IE
    • /
    • 제43권4호
    • /
    • pp.83-92
    • /
    • 2006
  • EMC를 정량 Moulding 후 잔량 처리와 작동 시 역 차단 방식의 설계하여 기계적 동작에 의해 흡입이 일어나도록 하여 Needle Tip의 잔량과 사인 현상을 해결하였다. 본 논문에서는 Gun과 세척제 Tank를 직결하도록 설계하여 세척이 용이하며, 원하는 량을 미리 계량하여 정밀 정량을 고속으로 EMC를 Molding 할 수 있도록 개발하기 때문에 반도체 Packaging 공정에 필수적인 장비라고 사료된다.

배관내 압력변동 신호를 이용한 유량 추정 방법 연구 (A Study on Flow Rate Estimation Using Pressure Fluctuation Signals in Pipe)

  • 이정한;장대식;박진호
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.155-162
    • /
    • 2023
  • In nuclear power plants, the flow rate information is a major indicator of the performance of rotating equipment such as pumps, and is a very important one required for facility operation and maintenance. To measure a flow rate, various types of methods have been developed and used. Among them, the differential pressure type using orifice and the direct doppler type using ultrasonic waves are the most commonly used. However, these flow rate measurement methods have limitations in installation, conditions and status of the measuring part, etc. To solve this problem, we have studied a new technique for measuring flow rate from scratch. In this paper, we have devised a technique to estimate the flow rate using an average moving velocity of large-scale eddy in turbulence that occurs in the piping flow field. The velocity of the large-scale eddy can be measured using the pressure fluctuation signals on the inner surface of the pipe. To estimate the flow rate, at first a cross-correlation function is applied to the two pressure fluctuation signals located at different positions in the down stream for calculating the time delay between the moving eddies. In order to validate the proposed flow rate estimation method, CFD analyses for the internal turbulence flow in pipe are conducted with a fixed flow condition, where the pressure fluctuation signals on the pipe inner surface are simulated. And then the average flow velocity of the large scale eddy is to be estimated. The estimated flow velocity is turned out to be similar to the fixed (known) flow rate.

℃ 이하 적외선 복사온도계 비교 교정장치 구축 (Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below ℃)

  • 유용심;김봉학
    • 한국광학회지
    • /
    • 제29권2호
    • /
    • pp.70-76
    • /
    • 2018
  • $0^{\circ}C$ 이하 적외선 복사온도계의 복사온도눈금 교정을 위해 기준 복사온도계 TRT2 (Transfer Radiation Thermometer 2, HEITRONICS)와 온도가변 흑체 ME30 (Model: ME30, HEITRONICS)을 사용하여 비교 교정장치를 구축하였다. 3개의 고정점(Ice ($0.01^{\circ}C$), In ($156.5985^{\circ}C$), Sn ($231.928^{\circ}C$))과 플랑크형 사쿠마-하토리식을 사용하고, $-50^{\circ}C$에서 TRT2의 내외삽 오차를 불확도에 포함시켜 TRT2의 복사온도 눈금을 교정하였다. ME30 흑체 개구에 공압으로 동작되는 뚜껑을 설치한 후 30초 동안만 뚜껑을 열고 복사온도를 측정함으로써 ME30 내에서 생기는 성에를 방지할 수 있었으며 비교 교정에 소요되는 시간도 반으로 줄일 수 있었다. $0{\sim}232^{\circ}C$ 영역 밖으로 벗어날수록 비교 교정장치의 불확도는 증가하며 $-20^{\circ}C$에서 확장 불확도는 0.26 K였다.

레이저 계측기를 이용한 축의 비틀림 진동에 관한 실험적 기초 연구 (The Experimental and Basic Study on Torsional Vibration of Horizontal Rotating Shaft using a Laser Measuring Equipment)

  • 박일수
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the nose of cam in the automobile engine was modelled into circular disk to analyze the torsional vibration of the cam shaft. The distance between disks was fixed, but the diameter of disks was changed. The torsional vibration of the cam shaft was studied experimentally by the motion of the modelled disk with changing the disk diameter. And the sizes of the modelled disk were selected not to show the natural frequencies over all the experimental ranges. The torsional vibration meter used in this study has a laser system with non-contact measurement method, which can measure both torsional angular vibration velocity and torsional angular vibration displacement simultaneously. The Experimental analysis shows that the characteristics of the torsional vibration in the horizontal rotating shaft can be considerably affected by the arrangement of the modelled disks.

  • PDF

집적암거에 의한 대류수개발에 관한 연구 (A study on the Development of Ground water by the Infiltration Gallery)

  • 한욱동
    • 한국농공학회지
    • /
    • 제15권3호
    • /
    • pp.3096-3106
    • /
    • 1973
  • As a link in the chain of antidrought measure, our attempt is made to obtain basic informations on the construction of an infiltration gallary which can be supplied with irrigation water by catching of underground water in small river beds, which is economical, permanent and efficient. The experiment was made, concerning the structure of catchment conduits, by constructing a model sand tank $1.5m{\times}5m{\times}1.5m$ in dimension made of reinforced concrete. Various kinds of measuring equipment were attached to the model tank which contains a set of catchment conduits, each of them was made 30cm in diameter and 60cm in length with the ratio of sectional area to total area of influx holes 10:1, 20:1, 30:1. The average size of influx holes was fixed from 0mm to 10mm, 20mm and 30mm in diameter respectively. Obtained results are as follow; (a) In view of the water catchment capacity, manufacturing cost and the antipressure strength of the catchment conduits, it is the best method to decide the total number of influx holes 20 per sq. meter of each tile surface, and the size of influx holes 20mm in diameter, when the conduits have diameter less than 1m. (b) The greatest factor of safety against external load is to arrange the influx holes in a zigzag manner on the tile surface. The most effective formula of arrangement is $S{\geqq}\sqrt{2gd}$ where: s : spacing of opening row. g : spacing of opening line. d : diameter of influs hole.

  • PDF

Uncertainty, Corporate Investment and the Role of Conservative Financial Reporting: Empirical Evidence from Pakistan

  • FATIMA, Huma;RANA, Sahar Latif;HAFEEZ, Abida
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권6호
    • /
    • pp.231-243
    • /
    • 2022
  • The objective of this study is to analyze the impact of conservative financial reporting on investment during uncertainty. It was assumed that during uncertainty conservative financial reporting can play an important role to improve investment decision-making. For our analysis, data sets from 2005-2020 of nonfinancial companies are used. To measure the impact of conservative financial reporting in the non-financial sector of Pakistan, Khan and Watts' (2009) model is applied. "Prospector" and "Defender" Business strategy is applied for measuring firm-level uncertainty. Investment is measured by adding the change in fixed assets (property, plant, and equipment). To check the robustness of conservative financial reporting, Givoly and Hayn's (2000) Negative Accruals measure is applied. To measure the robustness of uncertainty, environmental scanning and alertness technique is applied. According to environmental scanning and alertness technique, companies are divided into two groups named 'inert' and 'alert'. 'Inert' are those firms that are not scanning their environment, and 'alert' are those firms who continuously analyze their environment. The empirical estimations support our hypothesis. The empirical findings provide the proof that in the wake of uncertainty conservative financial reporting may facilitate to take optimal investment decisions in the developing economy of Pakistan. Our results provide critical and practical implications for investors, researchers, and standard setters.